Literature DB >> 15220497

Nationwide Evaluation of X-ray Trends survey of abdomen and lumbosacral spine radiography.

David C Spelic1, Richard V Kaczmarek, Orhan H Suleiman.   

Abstract

Results of the 1995 Nationwide Evaluation of X-ray Trends (NEXT) survey of facilities that perform diagnostic radiographic examinations of the abdomen and lumbosacral spine were compared with those of previous NEXT surveys conducted in 1987 and 1989. A clinically validated radiographic phantom was used in the 1995 survey to capture data about radiation exposure and image quality. Additional data were obtained regarding clinical techniques, facility workloads, x-ray beam quality, film processing quality, and darkroom fog. Mean skin-entrance air kerma for the abdomen examination dropped from 3.2 mGy (in 1987) to 2.8 mGy at hospitals and from 3.4 mGy (in 1989) to 3.0 mGy at nonhospital facilities. Mean skin-entrance air kerma also decreased for the lumbosacral spine examination from 3.7 mGy (in 1987) to 3.3 mGy at hospitals and from 3.8 mGy (in 1989) to 3.2 mGy at nonhospital facilities. The quality of film processing improved, although 58 (18.3%) of 317 surveyed facilities did not meet the Mammography Quality Standards Act standard for film processing quality, compared with 185 (5.9%) of 3,120 mammography facilities inspected in 1995. Finally, 181 (58.0%) of 312 surveyed facilities had darkroom fog levels greater than the Mammography Quality Standards Act standard, compared with 1,426 (16.6%) of 8,605 mammography facilities inspected in 1995.

Entities:  

Mesh:

Year:  2004        PMID: 15220497     DOI: 10.1148/radiol.2321020397

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  4 in total

1.  Patient radiation dose audits for fluoroscopically guided interventional procedures.

Authors:  Stephen Baiter; Marvin Rosenstein; Donald L Miller; Beth Schueler; David Spelic
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

2.  Patient-Based Dose Audit for Common Radiographic Examinations With Digital Radiology Systems: A Retrospective Cross-Sectional Study.

Authors:  Khalid M Alshamrani; Abdulkader A Alkenawi; Bushra N Alghamdi; Rawan H Honain; Haneen A Alshehri; Marwah O Alshatiri; Noor Mail; Ahmed Subahi; Shaza S Alsharif; Abdulaziz A Qurashi; Shrooq Aldahery; Reham Kaifi
Journal:  Cureus       Date:  2021-05-13

3.  Highly reduced-dose CT of the lumbar spine in a human cadaver model.

Authors:  Malte Lennart Warncke; Nis Jesper Wiese; Enver Tahir; Susanne Sehner; Axel Heinemann; Marc Regier; Klaus Püschel; Gerhard Adam; Julius Matthias Weinrich; Azien Laqmani
Journal:  PLoS One       Date:  2020-10-08       Impact factor: 3.240

4.  Classification of X-Ray Attenuation Properties of Additive Manufacturing and 3D Printing Materials Using Computed Tomography From 70 to 140 kVp.

Authors:  Xiangjie Ma; Martin Buschmann; Ewald Unger; Peter Homolka
Journal:  Front Bioeng Biotechnol       Date:  2021-11-29
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.