Literature DB >> 15216303

SEQUENTIAL HEMODYNAMIC STUDIES OF THE IONESCU-SHILEY PERICARDIAL XENOGRAFT VALVE UP TO SIX YEARS AFTER IMPLANTATION.

Anand P. Tandon1, Donald R. Smith, Marian I. Ionescu.   

Abstract

Sequential hemodynamic studies consisting of one preoperative and three postoperative cardiac catheterizations were undertaken in 19 patients at approximately 1, 4, and 6 years after valve replacement. Thirteen patients had aortic and six patients had mitral pericardial xenograft valves. Significant improvement was noted in various hemodynamic parameters in both groups of patients at the postoperative studies as compared to the preoperative findings. In patients with aortic valve replacement, the peak systolic gradient was 7.0 +/- 1.2 mm Hg at rest, and 10.0 +/- 1.6 mm Hg after exercise during the third postoperative study. The calculated xenograft orifice areas were 1.6 +/- 0.1 cm(2) at rest and 2.1 +/- 0.2 cm(2) after exercise in the aortic group, and 2.2 +/- 0.2 cm(2) at rest and 2.7 +/- 0.2 cm(2) after exercise in the mitral group at the third postoperative investigation. No significant change was noted among the three postoperative studies in the hemodynamic parameters. The results confirm the maintenance of functional performance of the Ionescu-Shiley pericardial xenograft up to 73 months after valve replacement.

Entities:  

Year:  1979        PMID: 15216303      PMCID: PMC287795     

Source DB:  PubMed          Journal:  Cardiovasc Dis        ISSN: 0093-3546


  12 in total

1.  Hemodynamic changes after valve replacement with Starr-Edwards prostheses.

Authors:  J D Bristow; E L Kremkau
Journal:  Am J Cardiol       Date:  1975-05       Impact factor: 2.778

2.  Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. I.

Authors:  R GORLIN; S G GORLIN
Journal:  Am Heart J       Date:  1951-01       Impact factor: 4.749

3.  In vivo evaluation of the Lillehei-Kaster heart valve prosthesis.

Authors:  U Sigwart; H Schmidt; U Gleichmann; H G Borst
Journal:  Ann Thorac Surg       Date:  1976-09       Impact factor: 4.330

4.  The Björk-Shiley mitral valve prosthesis. A comparative study with different prosthesis orientations.

Authors:  V O Björk; K Böök; A Holmgren
Journal:  Ann Thorac Surg       Date:  1974-10       Impact factor: 4.330

5.  Late postoperative clinical and hemodynamic assessment of the early cloth-covered Starr-Edwards mitral valve prosthesis.

Authors:  R J Pietras; D M Long; K M Rosen
Journal:  J Thorac Cardiovasc Surg       Date:  1974-03       Impact factor: 5.209

6.  Clinical and haemodynamic results of aortic valve replacement with the Björk-Shiley tilting disc valve prosthesis.

Authors:  V O Björk; A Holmgren; C Olin; C O Ovenfors
Journal:  Scand J Thorac Cardiovasc Surg       Date:  1971

7.  In vitro hydrodynamic comparison of mitral valve prostheses at high flow rates.

Authors:  S Gabbay; D M McQueen; E L Yellin; R M Becker; R W Frater
Journal:  J Thorac Cardiovasc Surg       Date:  1978-12       Impact factor: 5.209

8.  Long-term haemodynamic evaluation of aortic pericardial xenograft.

Authors:  A P Tandon; D R Smith; W Whitaker; M I Ionescu
Journal:  Br Heart J       Date:  1978-06

9.  Long term clinical and haemodynamic evaluation of the Ionescu-Shiley pericardial xenograft heart valve.

Authors:  M I Ionescu; A P Tandon
Journal:  Thoraxchir Vask Chir       Date:  1978-08

10.  Heart valve replacement with the Ionescu-Shiley pericardial xenograft.

Authors:  M I Ionescu; A P Tandon; D A Mary; A Abid
Journal:  J Thorac Cardiovasc Surg       Date:  1977-01       Impact factor: 5.209

View more
  2 in total

1.  Echocardiographic assessment of the Ionescu-Shiley pericardial xenograft in the aortic position.

Authors:  Leonard W. Pechacek; Luis Solana; Carlos M. Decastro
Journal:  Cardiovasc Dis       Date:  1981-06

2.  Ionescu-Shiley pericardial xenograft valve: Hemodynamic evaluation and early clinical follow-up of 326 patients.

Authors:  David A. Ott; Aldemire T. Coelho; Denton A. Cooley; George J. Reul
Journal:  Cardiovasc Dis       Date:  1980-06
  2 in total