Literature DB >> 656233

Long-term haemodynamic evaluation of aortic pericardial xenograft.

A P Tandon, D R Smith, W Whitaker, M I Ionescu.   

Abstract

Haemodynamic studies were performed in 30 patients at a mean interval of 43.4 (range 27 to 59) months after aortic valve replacements with pericardial xenografts. Five valve sizes--19, 21, 23, 25, and 27 mm annulus diameter--were used. Of these 30 patients, 16 had preoperative haemodynamic investigations. Comparison of the pre- and postoperative data showed a marginal but significant increase in cardiac output (P less than 0.05). There was a significant reduction in the pulmonary wedge and left ventricular end-diastolic pressures at rest and on exercise (P less than 0.05 and P less than 0.01). At the postoperative study the mean peak systolic gradient was 8.3 mmHg at rest and 12.3 mmHg on exercise in patients with the smallest xenograft inserted (19 mm) and decreased with each corresponding increase in graft size, so that across the 27 mm graft it was hardly measurable. The calculated xenograft surface area ranged from 1.1 to 2.1 cm2 at rest and 1.3 to 2.4 cm2 during exercise. Aortic root angiography showed competent valves in all 30 patients, but a grade 1 to 2 perivalvular leak was shown in 8 patients. This long-term study has indicated significant circulatory improvement and very small transvalvular gradients in patients with aortic pericardial xenografts.

Entities:  

Mesh:

Year:  1978        PMID: 656233      PMCID: PMC483455          DOI: 10.1136/hrt.40.6.602

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  12 in total

1.  Hemodynamic changes after valve replacement with Starr-Edwards prostheses.

Authors:  J D Bristow; E L Kremkau
Journal:  Am J Cardiol       Date:  1975-05       Impact factor: 2.778

2.  In vivo evaluation of the Lillehei-Kaster heart valve prosthesis.

Authors:  U Sigwart; H Schmidt; U Gleichmann; H G Borst
Journal:  Ann Thorac Surg       Date:  1976-09       Impact factor: 4.330

3.  Method of managing the small aortic annulus during valve replacement.

Authors:  R H Blank; D F Pupello; L N Bessone; E E Harrison; S Sbar
Journal:  Ann Thorac Surg       Date:  1976-10       Impact factor: 4.330

4.  Five years' experience with the Björk-Shiley tilting-disc valve in isolated aortic valvular disease.

Authors:  V O Björk; A Henze; A Holmgren
Journal:  J Thorac Cardiovasc Surg       Date:  1974-09       Impact factor: 5.209

5.  The analysis and presentation of surgical results by actuarial methods.

Authors:  R P Anderson; L I Bonchek; G L Grunkemeier; L E Lambert; A Starr
Journal:  J Surg Res       Date:  1974-03       Impact factor: 2.192

6.  Clinical and haemodynamic results of aortic valve replacement with the Björk-Shiley tilting disc valve prosthesis.

Authors:  V O Björk; A Holmgren; C Olin; C O Ovenfors
Journal:  Scand J Thorac Cardiovasc Surg       Date:  1971

7.  A new central-flow tilting disc valve prosthesis. One year's clinical experience with 103 patients.

Authors:  V O Björk
Journal:  J Thorac Cardiovasc Surg       Date:  1970-09       Impact factor: 5.209

8.  Radiology of homograft aortic valves.

Authors:  P W Brandt; A H Roche; B G Barratt-Boyes; J B Lowe
Journal:  Thorax       Date:  1969-03       Impact factor: 9.139

9.  Sequential hemodynamic studies in patients having aortic valve replacement with the Ionescu-Shiley pericardial xenograft.

Authors:  A P Tandon; D R Smith; D A Mary; M I Ionescu
Journal:  Ann Thorac Surg       Date:  1977-08       Impact factor: 4.330

10.  Aortic valve replacement with the Hancock porcine xenograft.

Authors:  L H Cohn; J H Sanders; J J Collins
Journal:  Ann Thorac Surg       Date:  1976-09       Impact factor: 4.330

View more
  4 in total

1.  Echocardiographic assessment of the Ionescu-Shiley pericardial xenograft in the aortic position.

Authors:  Leonard W. Pechacek; Luis Solana; Carlos M. Decastro
Journal:  Cardiovasc Dis       Date:  1981-06

2.  Multiple valve replacement with pericardial xenograft. Clinical and haemodynamic study.

Authors:  A P Tandon; W Whitaker; M I Ionescu
Journal:  Br Heart J       Date:  1980-11

3.  Ionescu-Shiley pericardial xenograft valve: Hemodynamic evaluation and early clinical follow-up of 326 patients.

Authors:  David A. Ott; Aldemire T. Coelho; Denton A. Cooley; George J. Reul
Journal:  Cardiovasc Dis       Date:  1980-06

4.  SEQUENTIAL HEMODYNAMIC STUDIES OF THE IONESCU-SHILEY PERICARDIAL XENOGRAFT VALVE UP TO SIX YEARS AFTER IMPLANTATION.

Authors:  Anand P. Tandon; Donald R. Smith; Marian I. Ionescu
Journal:  Cardiovasc Dis       Date:  1979-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.