Literature DB >> 15214977

CyberKnife frameless stereotactic radiosurgery for spinal lesions: clinical experience in 125 cases.

Peter C Gerszten1, Cihat Ozhasoglu, Steven A Burton, William J Vogel, Barbara A Atkins, Shalom Kalnicki, William C Welch.   

Abstract

OBJECTIVE: The role of stereotactic radiosurgery for the treatment of intracranial lesions is well established. Its use for the treatment of spinal lesions has been limited by the availability of effective target-immobilizing devices. Conventional external beam radiotherapy lacks the precision to allow delivery of large doses of radiation near radiosensitive structures such as the spinal cord. The CyberKnife (Accuray, Inc., Sunnyvale, CA) is an image-guided frameless stereotactic radiosurgery system that allows for the radiosurgical treatment of spinal lesions. This study evaluated the feasibility and effectiveness of the treatment of spinal lesions with a single-fraction radiosurgical technique using the CyberKnife.
METHODS: The CyberKnife system uses the coupling of an orthogonal pair of x-ray cameras to a dynamically manipulated robot-mounted linear accelerator with six degrees of freedom that guides the therapy beam to the intended target without the use of frame-based fixation. Real-time imaging allows the tracking of patient movement. Cervical spine lesions were located and tracked relative to cranial bony landmarks; lower spinal lesions were tracked relative to fiducial bone markers. In this prospective cohort evaluation of a spine radiosurgery technique, 125 spinal lesions in 115 consecutive patients were treated with a single-fraction radiosurgery technique (45 cervical, 30 thoracic, 36 lumbar, and 14 sacral). There were 17 benign tumors and 108 metastatic lesions. All dose plans were calculated on the basis of computed tomographic images acquired from 1.25-mm slices with an inverse treatment planning technique. Radiosurgical circular cones ranging in diameter from 5 to 40 mm were used.
RESULTS: Tumor volume ranged from 0.3 to 232 cm(3) (mean, 27.8 cm(3)). Seventy-eight lesions had received external beam irradiation previously. Tumor dose was maintained at 12 to 20 Gy to the 80% isodose line (mean, 14 Gy); canal volume receiving more than 8 Gy ranged from 0.0 to 1.7 cm(3) (mean, 0.2 cm(3)). No acute radiation toxicity or new neurological deficits occurred during the follow-up period (range, 9-30 mo; median, 18 mo). Axial and radicular pain improved in 74 of 79 patients who were symptomatic before treatment.
CONCLUSION: This is the first large prospective evaluation of this frameless image-guided spinal radiosurgery system. The CyberKnife system was found to be feasible, safe, and effective. The major potential benefits of radiosurgical ablation of spinal lesions are short treatment time in an outpatient setting with rapid recovery and symptomatic response. This technique offers a successful therapeutic modality for the treatment of a variety of spinal lesions as a primary treatment or for lesions not amenable to open surgical techniques, in medically inoperable patients, in lesions located in previously irradiated sites, or as an adjunct to surgery.

Entities:  

Mesh:

Year:  2004        PMID: 15214977

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  36 in total

Review 1.  Image-guided intensity-modulated radiation therapy of spine tumors.

Authors:  Yoshiya Yamada; Michael Lovelock; Mark H Bilsky
Journal:  Curr Neurol Neurosci Rep       Date:  2006-05       Impact factor: 5.081

2.  Radiosurgery using the Cyberknife for benign spinal tumors: Korea Cancer Center Hospital experience.

Authors:  Ung-Kyu Chang; Chang Hun Rhee; Sang Min Youn; Dong Han Lee; Sukh Que Park
Journal:  J Neurooncol       Date:  2010-05-28       Impact factor: 4.130

3.  New frontiers in radiosurgery for the brain and body.

Authors:  Cole A Giller; Brian D Berger
Journal:  Proc (Bayl Univ Med Cent)       Date:  2005-10

Review 4.  Nonhemorrhagic cord contusion after percutaneous fiducial placement: case report and surgical recommendations.

Authors:  Quails E Stevens; Rob D Dickerman; Keith A Kattner; Ann R Stroink
Journal:  J Spinal Cord Med       Date:  2006       Impact factor: 1.985

5.  Assessment of image-guided CyberKnife radiosurgery for metastatic spine tumors.

Authors:  Jo-Ting Tsai; Jia-Wei Lin; Wen-Ta Chiu; Woei-Chyn Chu
Journal:  J Neurooncol       Date:  2009-03-03       Impact factor: 4.130

6.  Single-fraction image-guided extracranial radiosurgery for recurrent and metastatic abdominal and pelvic cancers: short-term local control, metabolic response, and toxicity.

Authors:  Charles L Perkins; Bassel El-Reyes; Edmund Simon; David Kooby; William Torres; John S Kauh; Charles A Staley; Jerome C Landry
Journal:  J Gastrointest Oncol       Date:  2010-09

Review 7.  Recent advances in intradural spinal tumors.

Authors:  Muhammad M Abd-El-Barr; Kevin T Huang; Ziev B Moses; J Bryan Iorgulescu; John H Chi
Journal:  Neuro Oncol       Date:  2018-05-18       Impact factor: 12.300

8.  A prospective study comparing radiographer- and clinician-based localization for patients with metastatic spinal cord compression (MSCC) to assess the feasibility of a radiographer-led service.

Authors:  Craig Lacey; Clare Ockwell; Imogen Locke; Karen Thomas; Julie Hendry; Helen McNair
Journal:  Br J Radiol       Date:  2015-08-18       Impact factor: 3.039

Review 9.  Extracranial radiosurgery--applications in the management of benign intradural spinal neoplasms.

Authors:  Christine Saraceni; Jonathan B Ashman; James S Harrop
Journal:  Neurosurg Rev       Date:  2009-01-28       Impact factor: 3.042

10.  Couch and multileaf collimator tracking: A clinical feasibility study for pancreas and liver treatment.

Authors:  Lei Zhang; Thomas LoSasso; Pengpeng Zhang; Margie Hunt; Gig Mageras; Grace Tang
Journal:  Med Phys       Date:  2020-09-11       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.