Literature DB >> 15205369

Detection of genetic variants of transthyretin by liquid chromatography-dual electrospray ionization fourier-transform ion-cyclotron-resonance mass spectrometry.

Angelito I Nepomuceno1, Christopher J Mason, David C Muddiman, H Robert Bergen, Steven R Zeldenrust.   

Abstract

BACKGROUND: One of the numerous proteins causing amyloidosis is transthyretin (TTR), a protein usually responsible for the transport of thyroxine and retinol-binding protein. Variants within TTR cause it to aggregate and form insoluble fibers that accumulate in tissue, leading to organ dysfunction.
METHODS: TTR was immunoprecipitated from serum by use of a polyclonal antibody and subsequently reduced with tris(2-carboxyethyl)phosphine. The purified TTR was then analyzed by fast-gradient liquid chromatography-dual-electrospray ionization Fourier-transform ion-cyclotron-resonance (FT-ICR) mass spectrometry. DNA sequencing was performed on all samples used in this study.
RESULTS: Because of the inherent limitations in achieving high mass measurement accuracy based on the most abundant isotopic mass, we applied a fitting procedure that allowed determination of monoisotopic mass. Wild-type TTR (mean molecular mass, 13,761 Da) and its associated variant forms could be distinguished because of the high molecular mass accuracy afforded by FT-ICR (< or = 3 ppm) except for instances involving isobaric species or when isotopic distributions overlapped significantly. The [M + 11 H+]11+ charge state for all samples was used to determine the mass accuracies for both wild-type and variant forms of the protein. We correctly assigned seven of seven TTR variants. Moreover, using a combination of proteomic and genomic technologies, we discovered and characterized a previously unreported cis double mutation with a mass only 2 Da different from wild-type TTR. Furthermore, DNA sequencing of the TTR gene for all individuals in this study completely agreed with the intact protein measurements.
CONCLUSIONS: FT-ICR mass spectrometry has sufficient mass accuracy to identify genetic variants of immunoaffinity-purified TTR. We believe that 91% of known TTR variants could be detected by this technique.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15205369     DOI: 10.1373/clinchem.2004.033274

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  17 in total

1.  Generation and detection of multiply-charged peptides and proteins by matrix-assisted laser desorption electrospray ionization (MALDESI) Fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Jason S Sampson; Adam M Hawkridge; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2006-09-06       Impact factor: 3.109

2.  Sub parts-per-million mass measurement accuracy of intact proteins and product ions achieved using a dual electrospray ionization quadrupole fourier transform ion cyclotron resonance mass spectrometer.

Authors:  D Keith Williams; Adam M Hawkridge; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2006-09-18       Impact factor: 3.109

Review 3.  Candidate-based proteomics in the search for biomarkers of cardiovascular disease.

Authors:  Leigh Anderson
Journal:  J Physiol       Date:  2004-12-20       Impact factor: 5.182

4.  Mass spectrometric immunoassay for quantitative determination of transthyretin and its variants.

Authors:  Olgica Trenchevska; Elena Kamcheva; Dobrin Nedelkov
Journal:  Proteomics       Date:  2011-08-09       Impact factor: 3.984

5.  Parts-per-billion mass measurement accuracy achieved through the combination of multiple linear regression and automatic gain control in a Fourier transform ion cyclotron resonance mass spectrometer.

Authors:  D Keith Williams; David C Muddiman
Journal:  Anal Chem       Date:  2007-06-01       Impact factor: 6.986

6.  Determination of unique amino acid substitutions in protein variants by peptide mass mapping with FT-ICR MS.

Authors:  Katsuhiro Tanaka; Shigeo Takenaka; Shingo Tsuyama; Yoshinao Wada
Journal:  J Am Soc Mass Spectrom       Date:  2006-02-20       Impact factor: 3.109

7.  "Proteotyping": population proteomics of human leukocytes using top down mass spectrometry.

Authors:  Michael J Roth; Bryan A Parks; Jonathan T Ferguson; Michael T Boyne; Neil L Kelleher
Journal:  Anal Chem       Date:  2008-03-20       Impact factor: 6.986

8.  Identification of amino acid substitutions in avian influenza virus (H5N1) matrix protein 1 by using nanoelectrospray MS and MS/MS.

Authors:  Ning Liu; Wenjun Song; Kim-Chung Lee; Pui Wang; Honglin Chen; Zongwei Cai
Journal:  J Am Soc Mass Spectrom       Date:  2008-10-18       Impact factor: 3.109

9.  Identification of a novel proteoform of prostate specific antigen (SNP-L132I) in clinical samples by multiple reaction monitoring.

Authors:  Akos Végvári; Karin Sjödin; Melinda Rezeli; Johan Malm; Hans Lilja; Thomas Laurell; György Marko-Varga
Journal:  Mol Cell Proteomics       Date:  2013-07-10       Impact factor: 5.911

Review 10.  Top-down proteomics in health and disease: challenges and opportunities.

Authors:  Zachery R Gregorich; Ying Ge
Journal:  Proteomics       Date:  2014-05       Impact factor: 3.984

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.