Literature DB >> 16952462

Generation and detection of multiply-charged peptides and proteins by matrix-assisted laser desorption electrospray ionization (MALDESI) Fourier transform ion cyclotron resonance mass spectrometry.

Jason S Sampson1, Adam M Hawkridge, David C Muddiman.   

Abstract

We report the coupling of a hybrid ionization source, matrix-assisted laser desorption electrospray ionization (MALDESI), to a Fourier transform-ion cyclotron resonance mass spectrometer (FT-ICR MS). The details of the source design and initial data are presented. Analysis of peptides and proteins ranging from 1 to 8.6 kDa resulted in high resolving power single-acquisition FT-ICR mass spectra with average charge-states highly correlated to those obtained by nanoESI, thus, providing strong evidence that the ESI process dictates the observed charge-state distribution. Importantly, unlike the recently introduced electrospray assisted laser desorption ionization (ELDI) source reported by Shiea and coworkers [1, 2], the data we have obtained to date rely on the use of an organic acid matrix. The results presented herein provide insight into the charging mechanism of this emerging ionization approach, while also expanding the utility of FT-ICR MS for top-down protein and complex mixture analysis.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16952462     DOI: 10.1016/j.jasms.2006.08.003

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  20 in total

1.  Generating multiply charged protein ions via two-step electrospray ionization mass spectrometry.

Authors:  Chia-Cheng Lee; Der-Yeou Chang; Jingyueh Jeng; Jentaie Shiea
Journal:  J Mass Spectrom       Date:  2002-01       Impact factor: 1.982

2.  Incorporation of a venturi device in electrospray ionization.

Authors:  Li Zhou; Bingfang Yue; David V Dearden; Edgar D Lee; Alan L Rockwood; Milton L Lee
Journal:  Anal Chem       Date:  2003-11-01       Impact factor: 6.986

Review 3.  Top-down proteomics.

Authors:  Neil L Kelleher
Journal:  Anal Chem       Date:  2004-06-01       Impact factor: 6.986

4.  Novel linear quadrupole ion trap/FT mass spectrometer: performance characterization and use in the comparative analysis of histone H3 post-translational modifications.

Authors:  John E P Syka; Jarrod A Marto; Dina L Bai; Stevan Horning; Michael W Senko; Jae C Schwartz; Beatrix Ueberheide; Benjamin Garcia; Scott Busby; Tara Muratore; Jeffrey Shabanowitz; Donald F Hunt
Journal:  J Proteome Res       Date:  2004 May-Jun       Impact factor: 4.466

5.  Atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry.

Authors:  V V Laiko; M A Baldwin; A L Burlingame
Journal:  Anal Chem       Date:  2000-02-15       Impact factor: 6.986

6.  Electrospray-assisted laser desorption/ionization mass spectrometry for direct ambient analysis of solids.

Authors:  Jentaie Shiea; Min-Zon Huang; Hsiu-Jung Hsu; Chi-Yang Lee; Cheng-Hui Yuan; Iwona Beech; Jan Sunner
Journal:  Rapid Commun Mass Spectrom       Date:  2005       Impact factor: 2.419

7.  Versatile new ion source for the analysis of materials in open air under ambient conditions.

Authors:  Robert B Cody; James A Laramée; H Dupont Durst
Journal:  Anal Chem       Date:  2005-04-15       Impact factor: 6.986

8.  Fourier-transform mass spectrometry of large molecules by electrospray ionization.

Authors:  K D Henry; E R Williams; B H Wang; F W McLafferty; J Shabanowitz; D F Hunt
Journal:  Proc Natl Acad Sci U S A       Date:  1989-12       Impact factor: 11.205

9.  Gentle protein ionization assisted by high-velocity gas flow.

Authors:  Pengxiang Yang; R Graham Cooks; Zheng Ouyang; Adam M Hawkridge; David C Muddiman
Journal:  Anal Chem       Date:  2005-10-01       Impact factor: 6.986

10.  Mass spectrometry sampling under ambient conditions with desorption electrospray ionization.

Authors:  Zoltán Takáts; Justin M Wiseman; Bogdan Gologan; R Graham Cooks
Journal:  Science       Date:  2004-10-15       Impact factor: 47.728

View more
  84 in total

1.  Infrared laser ablation sample transfer for MALDI and electrospray.

Authors:  Sung-Gun Park; Kermit King Murray
Journal:  J Am Soc Mass Spectrom       Date:  2011-05-28       Impact factor: 3.109

2.  Electrospray post-ionization mass spectrometry of electrosurgical aerosols.

Authors:  Sabine Guenther; Karl-Christian Schäfer; Júlia Balog; Júlia Dénes; Tamás Majoros; Katalin Albrecht; Miklós Tóth; Bernhard Spengler; Zoltán Takáts
Journal:  J Am Soc Mass Spectrom       Date:  2011-09-03       Impact factor: 3.109

Review 3.  Mass spectrometric imaging for biomedical tissue analysis.

Authors:  Kamila Chughtai; Ron M A Heeren
Journal:  Chem Rev       Date:  2010-05-12       Impact factor: 60.622

4.  Laser Ablation with Vacuum Capture for MALDI Mass Spectrometry of Tissue.

Authors:  Fabrizio Donnarumma; Fan Cao; Kermit K Murray
Journal:  J Am Soc Mass Spectrom       Date:  2015-09-15       Impact factor: 3.109

5.  Analysis of Antiretrovirals in Single Hair Strands for Evaluation of Drug Adherence with Infrared-Matrix-Assisted Laser Desorption Electrospray Ionization Mass Spectrometry Imaging.

Authors:  Elias P Rosen; Corbin G Thompson; Mark T Bokhart; Heather M A Prince; Craig Sykes; David C Muddiman; Angela D M Kashuba
Journal:  Anal Chem       Date:  2015-12-30       Impact factor: 6.986

6.  Detection of attomole amounts of analyte by desorption electrospray ionization mass spectrometry (DESI-MS) determined using fluorescence spectroscopy.

Authors:  Michael S Bereman; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2007-03-21       Impact factor: 3.109

7.  IR-MALDESI Mass Spectrometry Imaging at 50 Micron Spatial Resolution.

Authors:  Mark T Bokhart; Jeffrey Manni; Kenneth P Garrard; Måns Ekelöf; Milad Nazari; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2017-07-18       Impact factor: 3.109

8.  Mapping the regioisomeric distribution of fatty acids in triacylglycerols by hybrid mass spectrometry.

Authors:  Kornél Nagy; Laurence Sandoz; Frédéric Destaillats; Olivier Schafer
Journal:  J Lipid Res       Date:  2012-10-23       Impact factor: 5.922

9.  Cellular-level mass spectrometry imaging using infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) by oversampling.

Authors:  Milad Nazari; David C Muddiman
Journal:  Anal Bioanal Chem       Date:  2014-12-09       Impact factor: 4.142

10.  Coupling matrix-assisted ionization with high resolution mass spectrometry and electron transfer dissociation to characterize intact proteins and post-translational modifications.

Authors:  Bingming Chen; Christopher B Lietz; Lingjun Li
Journal:  Anal Bioanal Chem       Date:  2017-09-12       Impact factor: 4.142

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.