Literature DB >> 15205243

Autogenous temporalis fascia patch graft for porous polyethylene (Medpor) sphere orbital implant exposure.

M S Sagoo1, J M Olver.   

Abstract

BACKGROUND: Temporalis fascia has been recommended for hydroxyapatite sphere exposure. The aim of this study was to identify potential risk factors for exposure of porous polyethylene (Medpor) sphere implants and evaluate the use of autogenous temporalis fascia as a patch graft for exposure.
METHODS: A retrospective review of consecutive cases of porous polyethylene sphere orbital implant exposure.
RESULTS: Five cases presented between May 2000 and October 2001 (three males, two females; mean age 44.5 years). Three had enucleation (two with primary implants) and two had evisceration (one with primary implant). Exposure occurred in one primary, two secondary, and two replacement implants. Orbital implant diameter was 20 mm in four cases and 16 mm in one case (contracted socket). The mean time from implantation to exposure was 23 months (range 0.7-42.6). Three patients had secondary motility peg placement before exposure. The average time from last procedure (sphere implant or peg insertion) to exposure was 3 months (range 0.7-12.6). Four patients required surgical intervention, of which three needed more than one procedure. Autogenous temporalis fascia grafting successfully closed the defect without re-exposure in three of these four patients. The grafts were left bare in three patients, with a mean time to conjunctivalise of 2.4 months (range 1.6-3.2).
CONCLUSIONS: Exposed porous polyethylene sphere implants were treated successfully with autogenous temporalis fascia graft in three of four patients. This technique is useful, the graft easy to harvest, and did not lead to prolonged socket inflammation, infection, or extrusion.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15205243      PMCID: PMC1772235          DOI: 10.1136/bjo.2003.026823

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  26 in total

1.  [Evisceration using the Russian doll or the parachute technique].

Authors:  J P Adenis; J Y Rulfi; P Y Robert
Journal:  J Fr Ophtalmol       Date:  2001-10       Impact factor: 0.818

2.  A simplified scleral graft technique for covering an exposed orbital implant.

Authors:  M F Goldberg
Journal:  Ophthalmic Surg       Date:  1988-03

3.  Primary banked scleral patch graft in the prevention of exposure of hydroxyapatite orbital implants.

Authors:  Clare F Inkster; Stephen G J Ng; Brian Leatherbarrow
Journal:  Ophthalmology       Date:  2002-02       Impact factor: 12.079

4.  Porous polyethylene implants for nasal reconstruction: clinical and histologic studies.

Authors:  I Niechajev
Journal:  Aesthetic Plast Surg       Date:  1999 Nov-Dec       Impact factor: 2.326

5.  [Porous polyethylene (Medpor) orbital implant. Prospective study of 75 primary implantations].

Authors:  E Van Acker; P De Potter
Journal:  J Fr Ophtalmol       Date:  2001-12       Impact factor: 0.818

6.  A long-term follow-up study of scleral grafting for exposed or extruded orbital implants.

Authors:  J A Fountain; E M Helveston
Journal:  Am J Ophthalmol       Date:  1982-01       Impact factor: 5.258

7.  Extruding orbital implant: prevention and treatment.

Authors:  M R Levine
Journal:  Ann Ophthalmol       Date:  1980-12

8.  Exposure of high-density porous polyethylene (Medpor) used for contour restoration and treatment.

Authors:  K Sevin ; I Askar; A Saray; E Yormuk
Journal:  Br J Oral Maxillofac Surg       Date:  2000-02       Impact factor: 1.651

9.  Exposure of primary orbital implants in postenucleation retinoblastoma patients.

Authors:  V Lee; I Subak-Sharpe; J L Hungerford; N P Davies; S Logani
Journal:  Ophthalmology       Date:  2000-05       Impact factor: 12.079

10.  Postcontrast magnetic resonance imaging assessment of porous polyethylene orbital implant (Medpor).

Authors:  P De Potter; T Duprez; G Cosnard
Journal:  Ophthalmology       Date:  2000-09       Impact factor: 12.079

View more
  7 in total

1.  Amniotic membrane transplantation for porous sphere orbital implant exposure.

Authors:  Yan-hong Chen; Hong-guang Cui
Journal:  J Zhejiang Univ Sci B       Date:  2007-09       Impact factor: 3.066

2.  Remove, rotate, and reimplant: a novel technique for the management of exposed porous anophthalmic implants in eviscerated patients.

Authors:  P Kaynak; G O Karabulut; C Ozturker; I Perente; B Gökyiǧit; A Demirok; O F Yilmaz
Journal:  Eye (Lond)       Date:  2014-02-07       Impact factor: 3.775

3.  Effect of basic fibroblast growth factor (bFGF) on the treatment of exposure of the orbital implants.

Authors:  Hong-guang Cui; Hui-yan Li
Journal:  J Zhejiang Univ Sci B       Date:  2007-09       Impact factor: 3.066

4.  The efficacy of acrylic acid grafting and arginine-glycine-aspartic acid peptide immobilization on fibrovascular ingrowth into porous polyethylene implants in rabbits.

Authors:  Byung Woo Park; Hee Seok Yang; Se Hyun Baek; Kwideok Park; Dong Keun Han; Tae Soo Lee
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-11-22       Impact factor: 3.535

5.  Evisceration in the modern age.

Authors:  Laura T Phan; Thomas N Hwang; Timothy J McCulley
Journal:  Middle East Afr J Ophthalmol       Date:  2012-01

6.  Complications of orbital endoimplantation in the Eye Clinic of the Lithuanian University of Health Sciences.

Authors:  Raimonda Piškinienė; Mantas Banevičius
Journal:  Acta Med Litu       Date:  2017

7.  Use of extraocular muscle flaps in the correction of orbital implant exposure.

Authors:  Hsueh-Yen Chu; Yi-Lin Liao; Yueh-Ju Tsai; Yen-Chang Chu; Shu-Ya Wu; Lih Ma
Journal:  PLoS One       Date:  2013-09-25       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.