Literature DB >> 15200119

Intraaneurysmal flow visualization by using phase-contrast magnetic resonance imaging: feasibility study based on a geometrically realistic in vitro aneurysm model.

Satoshi Tateshima1, John Grinstead, Shantanu Sinha, Yih-lin Nien, Yuichi Murayama, J Pablo Villablanca, Kazuo Tanishita, Fernando Viñuela.   

Abstract

OBJECT: The aim of this study was to evaluate the feasibility of complex intraaneurysmal flow visualization with the currently available phase-contrast magnetic resonance (MR) imaging modality.
METHODS: A geometrically realistic in vitro aneurysm model, in which detailed flow velocity analysis had already been conducted using laser Doppler velocimetry was used for this in vitro hemodynamic simulation, so that the results of phase-contrast velocity measurements could be compared with the previous reliable results. On a 1.5-tesla unit, three orthogonal components of velocity were obtained using a standard two-dimensional fast low-angle shot flow quantification sequence. Three-dimensional (3D) intraaneurysmal flow structures recorded during one cardiac cycle were depicted in one midsagittal and three axial cross-sectional planes with the aid of gray scale phase-contrast velocity maps. Isovelocity contour maps and secondary flow vectors were also created based on the phase-contrast velocity maps by using MATLAB software. The isovelocity contours in those three axial sections could demonstrate the shapes of inward and outward flow areas and their alternation over one cardiac cycle. The secondary flow vectors demonstrated twin vortices within the outward flow area adjacent to the boundary layer of inward and outward flow in all axial planes.
CONCLUSIONS: The phase-contrast MR imaging method was able to depict the complex 3D intraaneurysmal flow structures in the in vitro aneurysm model. Detailed 3D intraaneurysmal flow information will be obtainable in vivo after improvements are made in spatial resolution, which is expected in the near future. The capability to visualize intraaneurysmal flow structures directly with the use of noninvasive MR imaging technology will have a positive impact on future clinical practice.

Entities:  

Mesh:

Year:  2004        PMID: 15200119     DOI: 10.3171/jns.2004.100.6.1041

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  6 in total

1.  Visualization of hemodynamics in a silicon aneurysm model using time-resolved, 3D, phase-contrast MRI.

Authors:  H Isoda; M Hirano; H Takeda; T Kosugi; M T Alley; M Markl; N J Pelc; H Sakahara
Journal:  AJNR Am J Neuroradiol       Date:  2006-05       Impact factor: 3.825

2.  In vivo visualization and analysis of 3-D hemodynamics in cerebral aneurysms with flow-sensitized 4-D MR imaging at 3 T.

Authors:  Stephan Meckel; Aurelien F Stalder; Francesco Santini; Ernst-Wilhelm Radü; Daniel A Rüfenacht; Michael Markl; Stephan G Wetzel
Journal:  Neuroradiology       Date:  2008-03-19       Impact factor: 2.804

3.  Noninvasive measurement of intra-aneurysmal pressure and flow pattern using phase contrast with vastly undersampled isotropic projection imaging.

Authors:  R Moftakhar; B Aagaard-Kienitz; K Johnson; P A Turski; A S Turk; D B Niemann; D Consigny; J Grinde; O Wieben; C A Mistretta
Journal:  AJNR Am J Neuroradiol       Date:  2007-09-20       Impact factor: 3.825

4.  Intra-aneurysmal hemodynamics during the growth of an unruptured aneurysm: in vitro study using longitudinal CT angiogram database.

Authors:  S Tateshima; K Tanishita; H Omura; J P Villablanca; F Vinuela
Journal:  AJNR Am J Neuroradiol       Date:  2007-04       Impact factor: 3.825

5.  Phase-contrast magnetic resonance imaging measurements in intracranial aneurysms in vivo of flow patterns, velocity fields, and wall shear stress: comparison with computational fluid dynamics.

Authors:  Loic Boussel; Vitaliy Rayz; Alastair Martin; Gabriel Acevedo-Bolton; Michael T Lawton; Randall Higashida; Wade S Smith; William L Young; David Saloner
Journal:  Magn Reson Med       Date:  2009-02       Impact factor: 4.668

Review 6.  Hemodynamics of cerebral aneurysms: computational analyses of aneurysm progress and treatment.

Authors:  Woowon Jeong; Kyehan Rhee
Journal:  Comput Math Methods Med       Date:  2012-02-19       Impact factor: 2.238

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.