Literature DB >> 15174776

Positive pressure ventilation at neonatal resuscitation: review of equipment and international survey of practice.

C P F O'Donnell1, P G Davis, C J Morley.   

Abstract

BACKGROUND: The equipment used to provide positive pressure ventilation to newborns needing resuscitation at delivery varies between institutions. Devices were reviewed and their use surveyed in a sample of neonatal centres worldwide. AIM: To determine which equipment is used to resuscitate newborns at delivery in a sample of teaching hospitals around the world.
METHODS: A questionnaire was sent via e-mail to a neonatologist at each of 46 NICUs in 23 countries on five continents, asking which resuscitation equipment they used. If it was not returned, follow-up was by e-mail.
RESULTS: Data were obtained from 40 (87%) centres representing 19 countries. Round face masks are used at 34 (85%) centres, anatomically shaped masks are used exclusively at six (15%) and a mixture of types are used at 11 (28%). Straight endotracheal tubes are used exclusively at 36 (90%) centres: shouldered tubes are used infrequently at three of the four centres that have them. The self-inflating bag is the most commonly used manual ventilation device (used at 33 (83%) centres), the Laerdal Infant Resuscitator the most popular model. Flow-inflating bags are used at 10 (25%) centres. The Neopuff Infant Resuscitator is used at 12 (30%) centres. Varying oxygen concentrations are provided during neonatal resuscitation at half of the centres, while 100% oxygen is routinely used at the other half.
CONCLUSIONS: This survey shows considerable variation in practice, reflecting this lack of evidence and consequent uncertainty among clinicians. Comparison of the two most popular manual ventilation devices, the Laerdal Infant Resuscitator and the Neopuff Infant Resuscitator, is urgently required.

Entities:  

Mesh:

Year:  2004        PMID: 15174776     DOI: 10.1111/j.1651-2227.2004.tb02981.x

Source DB:  PubMed          Journal:  Acta Paediatr        ISSN: 0803-5253            Impact factor:   2.299


  18 in total

1.  Use of neonatal simulation models to assess competency in bag-mask ventilation.

Authors:  S A Pearlman; S C Zern; T Blackson; J A Ciarlo; A B Mackley; R G Locke
Journal:  J Perinatol       Date:  2015-11-19       Impact factor: 2.521

2.  The pressure is on! The danger of a broken blow off valve on a bag valve mask.

Authors:  S B Ainsworth; R Humphreys; L Stewart
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2006-05       Impact factor: 5.747

3.  Free-flow oxygen delivery to newly born infants.

Authors:  Jennifer A Dawson; Peter G Davis; Colm P F O'Donnell; C Omar F Kamlin; Colin J Morley
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2006-11-01       Impact factor: 5.747

4.  Neonatal resuscitation of extremely low birthweight infants: a survey of practice in Italy.

Authors:  D Trevisanuto; N Doglioni; P Ferrarese; R Bortolus; V Zanardo
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2006-03       Impact factor: 5.747

5.  Free-flow oxygen delivery using a T-piece resuscitator.

Authors:  Jennifer A Dawson; Peter G Davis; C Omar F Kamlin; Colin J Morley
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2007-09       Impact factor: 5.747

Review 6.  Sustained versus standard inflations during neonatal resuscitation to prevent mortality and improve respiratory outcomes.

Authors:  Matteo Bruschettini; Colm Pf O'Donnell; Peter G Davis; Colin J Morley; Lorenzo Moja; Simona Zappettini; Maria Grazia Calevo
Journal:  Cochrane Database Syst Rev       Date:  2017-07-14

7.  Neonatal resuscitation 3: manometer use in a model of face mask ventilation.

Authors:  C P F O'Donnell; P G Davis; R Lau; P A Dargaville; L W Doyle; C J Morley
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2005-05-04       Impact factor: 5.747

8.  Neonatal resuscitation 2: an evaluation of manual ventilation devices and face masks.

Authors:  C P F O'Donnell; P G Davis; R Lau; P A Dargaville; L W Doyle; C J Morley
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2005-05-04       Impact factor: 5.747

9.  Accuracy of a disposable compared to a non-disposable infant T-piece resuscitator.

Authors:  Vera B Krabbe; Jeroen J van Vonderen; Charles C Roehr; Arjan B Te Pas
Journal:  Eur J Pediatr       Date:  2014-02-16       Impact factor: 3.183

10.  Sustained versus standard inflations during neonatal resuscitation to prevent mortality and improve respiratory outcomes.

Authors:  Matteo Bruschettini; Colm Pf O'Donnell; Peter G Davis; Colin J Morley; Lorenzo Moja; Maria Grazia Calevo
Journal:  Cochrane Database Syst Rev       Date:  2020-03-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.