Literature DB >> 15171127

Intra-aneurysmal flow with helix and mesh stent placement across side-wall aneurysm pore of a straight parent vessel.

Tong-Miin Liou1, Shun-Nan Liou, Kai-Lung Chu.   

Abstract

Pulsatile flow fields in a cerebrovascular side-wall aneurysm model with a wide ostium after stenting are presented in terms of particle tracking velocimetry measurements and flow visualization. Among the stent parameters the shape, helix versus mesh, was selected to study its effect on the changes of intraaneurysmal hemodynamics for the reference of minimally invasive endovascular aneurysm treatment. The blocking ratio of the stents was fixed at 30%. The Womersley number was 3.9 and the mean, peak, and minimal Reynolds numbers based on the bulk average velocity and diameter of the parent vessel were 600, 850, and 300, respectively. Four consecutive flow-rate phases were selected to characterize the intra-aneurysmal flow. The results are characterized in terms of velocity vector field, regional average velocity, and intra-aneurysmal vorticity/circulation/wall shear stress. It is found that the hemodynamic features inside the aneurysm alter markedly with the shape of the stent and the size of the orifice. Both stents investigated induce favorable changes in the intra-aneurysmal flow stasis as well as direction and undulation of wall shear stresses. A comparison of the results of the helix to mesh stent shows that the former is more favorable for endovascular treatment.

Entities:  

Mesh:

Year:  2004        PMID: 15171127     DOI: 10.1115/1.1644566

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  9 in total

1.  Flow modification in canine intracranial aneurysm model by an asymmetric stent: studies using digital subtraction angiography (DSA) and image-based computational fluid dynamics (CFD) analyses.

Authors:  Yiemeng Hoi; Ciprian N Ionita; Rekha V Tranquebar; Kenneth R Hoffmann; Scott H Woodward; Dale B Taulbee; Hui Meng; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2006-03-13

2.  Saccular aneurysms on straight and curved vessels are subject to different hemodynamics: implications of intravascular stenting.

Authors:  H Meng; Z Wang; M Kim; R D Ecker; L N Hopkins
Journal:  AJNR Am J Neuroradiol       Date:  2006-10       Impact factor: 3.825

3.  Correlation of aneurysm occlusion with actual metal coverage at neck after implantation of flow-diverting stent in rabbit models.

Authors:  Kuizhong Wang; Qinghai Huang; Bo Hong; Zhen Li; Xinggen Fang; Jianmin Liu
Journal:  Neuroradiology       Date:  2011-08-27       Impact factor: 2.804

4.  Validation of CFD simulations of cerebral aneurysms with implication of geometric variations.

Authors:  Yiemeng Hoi; Scott H Woodward; Minsuok Kim; Dale B Taulbee; Hui Meng
Journal:  J Biomech Eng       Date:  2006-12       Impact factor: 2.097

5.  An optimized method for delivering flow tracer particles to intravital fluid environments in the developing zebrafish.

Authors:  Michael P Craig; Steven D Gilday; Dana Dabiri; Jay R Hove
Journal:  Zebrafish       Date:  2012-09       Impact factor: 1.985

6.  Comparison of two stents in modifying cerebral aneurysm hemodynamics.

Authors:  Minsuok Kim; Dale B Taulbee; Markus Tremmel; Hui Meng
Journal:  Ann Biomed Eng       Date:  2008-02-09       Impact factor: 3.934

7.  Particle imaging velocimetry evaluation of intracranial stents in sidewall aneurysm: hemodynamic transition related to the stent design.

Authors:  Pierre Bouillot; Olivier Brina; Rafik Ouared; Karl-Olof Lovblad; Mohamed Farhat; Vitor Mendes Pereira
Journal:  PLoS One       Date:  2014-12-03       Impact factor: 3.240

Review 8.  Endovascular Treatment of Intracranial Aneurysms.

Authors:  Antonis Adamou; Maria Alexandrou; Christian Roth; Achilles Chatziioannou; Panagiotis Papanagiotou
Journal:  Life (Basel)       Date:  2021-04-10

9.  Simulation of intra-aneurysmal blood flow by different numerical methods.

Authors:  Frank Weichert; Lars Walczak; Denis Fisseler; Tobias Opfermann; Mudassar Razzaq; Raphael Münster; Stefan Turek; Iris Grunwald; Christian Roth; Christian Veith; Mathias Wagner
Journal:  Comput Math Methods Med       Date:  2013-04-15       Impact factor: 2.238

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.