Literature DB >> 18264766

Comparison of two stents in modifying cerebral aneurysm hemodynamics.

Minsuok Kim1, Dale B Taulbee, Markus Tremmel, Hui Meng.   

Abstract

There is a general lack of quantitative understanding about how specific design features of endovascular stents (struts and mesh design, porosity) affect the hemodynamics in intracranial aneurysms. To shed light on this issue, we studied two commercial high-porosity stents (Tristar stent and Wallstent) in aneurysm models of varying vessel curvature as well as in a patient-specific model using Computational Fluid Dynamics. We investigated how these stents modify hemodynamic parameters such as aneurysmal inflow rate, stasis, and wall shear stress, and how such changes are related to the specific designs. We found that the flow damping effect of stents and resulting aneurysmal stasis and wall shear stress are strongly influenced by stent porosity, strut design, and mesh hole shape. We also confirmed that the damping effect is significantly reduced at higher vessel curvatures, which indicates limited usefulness of high-porosity stents as a stand-alone treatment. Finally, we showed that the stasis-inducing performance of stents in 3D geometries can be predicted from the hydraulic resistance of their flat mesh screens. From this, we propose a methodology to cost-effectively compare different stent designs before running a full 3D simulation.

Entities:  

Mesh:

Year:  2008        PMID: 18264766      PMCID: PMC2698293          DOI: 10.1007/s10439-008-9449-4

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  43 in total

Review 1.  Intracranial aneurysms: links among inflammation, hemodynamics and vascular remodeling.

Authors:  Tomoki Hashimoto; Hui Meng; William L Young
Journal:  Neurol Res       Date:  2006-06       Impact factor: 2.448

2.  Circumferential vascular deformation after stent implantation alters wall shear stress evaluated with time-dependent 3D computational fluid dynamics models.

Authors:  John F LaDisa; Lars E Olson; Ismail Guler; Douglas A Hettrick; Judy R Kersten; David C Warltier; Paul S Pagel
Journal:  J Appl Physiol (1985)       Date:  2004-11-05

3.  Alterations in wall shear stress predict sites of neointimal hyperplasia after stent implantation in rabbit iliac arteries.

Authors:  John F LaDisa; Lars E Olson; Robert C Molthen; Douglas A Hettrick; Phillip F Pratt; Michael D Hardel; Judy R Kersten; David C Warltier; Paul S Pagel
Journal:  Am J Physiol Heart Circ Physiol       Date:  2005-01-14       Impact factor: 4.733

4.  Efficient simulation of blood flow past complex endovascular devices using an adaptive embedding technique.

Authors:  Juan R Cebral; Rainald Löhner
Journal:  IEEE Trans Med Imaging       Date:  2005-04       Impact factor: 10.048

5.  Efficacy and current limitations of intravascular stents for intracranial internal carotid, vertebral, and basilar artery aneurysms.

Authors:  G Lanzino; A K Wakhloo; R D Fessler; M L Hartney; L R Guterman; L N Hopkins
Journal:  J Neurosurg       Date:  1999-10       Impact factor: 5.115

6.  Correlation between lumenal geometry changes and hemodynamics in fusiform intracranial aneurysms.

Authors:  Liang-Der Jou; Gregory Wong; Brad Dispensa; Michael T Lawton; Randall T Higashida; William L Young; David Saloner
Journal:  AJNR Am J Neuroradiol       Date:  2005-10       Impact factor: 3.825

7.  Characterization of cerebral aneurysms for assessing risk of rupture by using patient-specific computational hemodynamics models.

Authors:  Juan R Cebral; Marcelo A Castro; James E Burgess; Richard S Pergolizzi; Michael J Sheridan; Christopher M Putman
Journal:  AJNR Am J Neuroradiol       Date:  2005 Nov-Dec       Impact factor: 3.825

8.  Efficient pipeline for image-based patient-specific analysis of cerebral aneurysm hemodynamics: technique and sensitivity.

Authors:  Juan R Cebral; Marcelo A Castro; Sunil Appanaboyina; Christopher M Putman; Daniel Millan; Alejandro F Frangi
Journal:  IEEE Trans Med Imaging       Date:  2005-04       Impact factor: 10.048

9.  A steady flow analysis on the stented and non-stented sidewall aneurysm models.

Authors:  S C Yu; J B Zhao
Journal:  Med Eng Phys       Date:  1999-04       Impact factor: 2.242

10.  Treatment of experimentally induced aneurysms with stents.

Authors:  Timo Krings; Franz J Hans; Walter Möller-Hartmann; Anna Brunn; Ruth Thiex; Thomas Schmitz-Rode; Peter Verken; Kira Scherer; Heiko Dreeskamp; Klaus P Stein; Joachim Gilsbach; Armin Thron
Journal:  Neurosurgery       Date:  2005-06       Impact factor: 4.654

View more
  24 in total

Review 1.  Alteration of intra-aneurysmal hemodynamics for flow diversion using enterprise and vision stents.

Authors:  Markus Tremmel; Jianping Xiang; Sabareesh K Natarajan; L Nelson Hopkins; Adnan H Siddiqui; Elad I Levy; Hui Meng
Journal:  World Neurosurg       Date:  2010 Aug-Sep       Impact factor: 2.104

2.  The effect of intracranial stent implantation on the curvature of the cerebrovasculature.

Authors:  R M King; J-Y Chueh; I M J van der Bom; C F Silva; S L Carniato; G Spilberg; A K Wakhloo; M J Gounis
Journal:  AJNR Am J Neuroradiol       Date:  2012-04-26       Impact factor: 3.825

Review 3.  Current progress in patient-specific modeling.

Authors:  Maxwell Lewis Neal; Roy Kerckhoffs
Journal:  Brief Bioinform       Date:  2009-12-02       Impact factor: 11.622

4.  The 'Sphere': A Dedicated Bifurcation Aneurysm Flow-Diverter Device.

Authors:  Thomas Peach; J Frederick Cornhill; Anh Nguyen; Howard Riina; Yiannis Ventikos
Journal:  Cardiovasc Eng Technol       Date:  2014-08-26       Impact factor: 2.495

5.  Strategy for analysis of flow diverting devices based on multi-modality image-based modeling.

Authors:  Juan R Cebral; Fernando Mut; Marcelo Raschi; Yong-Hong Ding; Ramanathan Kadirvel; David Kallmes
Journal:  Int J Numer Method Biomed Eng       Date:  2014-04-09       Impact factor: 2.747

6.  Vertebrobasilar Dissection with Pseudo-aneurysm or Subarachnoid Hemorrhage: Intracranial Stenting as the Only Treatment. A Report of Three Cases.

Authors:  V Helyar; M Söderman; T Andersson; S Holmin
Journal:  Interv Neuroradiol       Date:  2009-04-15       Impact factor: 1.610

7.  Effect of hemodynamics on outcome of subtotally occluded paraclinoid aneurysms after stent-assisted coil embolization.

Authors:  Jian Liu; Linkai Jing; Chao Wang; Nikhil Paliwal; Shengzhang Wang; Ying Zhang; Jianping Xiang; Adnan H Siddiqui; Hui Meng; Xinjian Yang
Journal:  J Neurointerv Surg       Date:  2015-11-26       Impact factor: 5.836

8.  Hemodynamic alterations after stent implantation in 15 cases of intracranial aneurysm.

Authors:  Chao Wang; Zhongbin Tian; Jian Liu; Linkai Jing; Nikhil Paliwal; Shengzhang Wang; Ying Zhang; Jianping Xiang; Adnan H Siddiqui; Hui Meng; Xinjian Yang
Journal:  Acta Neurochir (Wien)       Date:  2016-01-08       Impact factor: 2.216

9.  The difference of each angiographic finding after multiple stent according to stent type in bilateral vertebral artery dissection.

Authors:  Dong Hoon Lee; Woon Ki Yoon; Min Woo Baik; Hoon Kim
Journal:  J Cerebrovasc Endovasc Neurosurg       Date:  2013-09-30

10.  Delayed aneurysm rupture due to residual blood flow at the inflow zone of the intracranial paraclinoid internal carotid aneurysm treated with the Pipeline embolization device: Histopathological investigation.

Authors:  Hiroyuki Ikeda; Akira Ishii; Takayuki Kikuchi; Mitsushige Ando; Hideo Chihara; Daisuke Arai; Etsuko Hattori; Susumu Miyamoto
Journal:  Interv Neuroradiol       Date:  2015-10-23       Impact factor: 1.610

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.