| Literature DB >> 15168007 |
R Verdonk1, D Cottenie, K F Almqvist, P Vorlat.
Abstract
Our medium- and long-term results obtained with the Oxford unicompartmental knee prosthesis for unicompartmental knee osteoarthrosis are presented. Ninety-seven prostheses were evaluated (87 medial, 10 lateral) in 86 patients, with the Hospital for Special Surgery knee score after 2-14 years (mean follow-up: 6 years 9 months). Five prostheses were lost to follow-up. Eight patients died, not related to surgery; none had undergone a revision. Fourteen revisions (of which one bilateral UKP), 11 medial and three lateral, were performed. The mean HSS score of the 69 UKPs was 178.8 (80% excellent, 10% good, 4% fair, 6% poor). These findings confirm the good results reported in other studies, regarding proper patient selection and a consistent operative technique.Entities:
Mesh:
Year: 2004 PMID: 15168007 DOI: 10.1007/s00167-004-0522-8
Source DB: PubMed Journal: Knee Surg Sports Traumatol Arthrosc ISSN: 0942-2056 Impact factor: 4.342