Literature DB >> 32419760

Lower limb kinematics of unicompartmental knee arthroplasty individuals during stair ascent.

Rumit Singh Kakar1, Yang-Chieh Fu2, Tracy L Kinsey3, Cathleen N Brown4, Ormonde M Mahoney3,5, Kathy J Simpson5.   

Abstract

OBJECTIVE: Purpose of the study was to compare lower-limb kinematics and interlimb asymmetry during stair ascent in individuals post-medial or lateral unicompartmental knee arthroplasty (UKA).
METHODS: 60 patients (20 medial; 10 lateral) post-UKA and 30 matched healthy controls performed stair ascent. Spatio-temporal, lower-limb kinematics and interlimb asymmetries during stair ascent were compared.
RESULTS: Medial-UKA group displayed 5° less knee extension of the UKA limb than controls (p = 0.005) and 2° less than the contralateral limb during stance phase. No interlimb asymmetries were found for lateral-UKA.
CONCLUSION: Patients post-UKA demonstrate satisfactory lower-limb kinematics and minimal interlimb asymmetry during stair ascent compared to healthy individuals.
© 2020 Professor P K Surendran Memorial Education Foundation. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Gait; Kinematics; Osteoarthritis; Stair; Unicompartmental knee arthroplasty

Year:  2020        PMID: 32419760      PMCID: PMC7215097          DOI: 10.1016/j.jor.2020.04.009

Source DB:  PubMed          Journal:  J Orthop        ISSN: 0972-978X


  46 in total

1.  Stair ascent and descent at different inclinations.

Authors:  Robert Riener; Marco Rabuffetti; Carlo Frigo
Journal:  Gait Posture       Date:  2002-02       Impact factor: 2.840

2.  ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion--part I: ankle, hip, and spine. International Society of Biomechanics.

Authors:  Ge Wu; Sorin Siegler; Paul Allard; Chris Kirtley; Alberto Leardini; Dieter Rosenbaum; Mike Whittle; Darryl D D'Lima; Luca Cristofolini; Hartmut Witte; Oskar Schmid; Ian Stokes
Journal:  J Biomech       Date:  2002-04       Impact factor: 2.712

3.  The practice of unicompartmental knee arthroplasty in the United Kingdom.

Authors:  Oliver S Schindler; W Norman Scott; Giles R Scuderi
Journal:  J Orthop Surg (Hong Kong)       Date:  2010-12       Impact factor: 1.118

4.  Unicompartmental or total knee replacement: the 15-year results of a prospective randomised controlled trial.

Authors:  J Newman; R V Pydisetty; C Ackroyd
Journal:  J Bone Joint Surg Br       Date:  2009-01

5.  Long-term results with a lateral unicondylar replacement.

Authors:  Jean-Noël A Argenson; Sebastien Parratte; Antoine Bertani; Xavier Flecher; Jean-Manuel Aubaniac
Journal:  Clin Orthop Relat Res       Date:  2008-06-24       Impact factor: 4.176

6.  Low rate of iatrogenic complications during unicompartmental knee arthroplasty with two semiautonomous robotic systems.

Authors:  Jess H Lonner; Glenn J Kerr
Journal:  Knee       Date:  2019-03-19       Impact factor: 2.199

7.  Improved implant position and lower revision rate with robotic-assisted unicompartmental knee arthroplasty.

Authors:  Cécile Batailler; Nathan White; Filippo Maria Ranaldi; Philippe Neyret; Elvire Servien; Sébastien Lustig
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-07-31       Impact factor: 4.342

8.  Unicompartmental or total knee arthroplasty?: Results from a matched study.

Authors:  Anish K Amin; James T Patton; Robert E Cook; Mark Gaston; Ivan J Brenkel
Journal:  Clin Orthop Relat Res       Date:  2006-10       Impact factor: 4.176

9.  Minimum 10-year outcomes of a fixed bearing all-polyethylene unicompartmental knee arthroplasty used to treat medial osteoarthritis.

Authors:  David J Bruce; Mohammed Hassaballa; James R Robinson; Andrew J Porteous; James R Murray; John H Newman
Journal:  Knee       Date:  2020-03-24       Impact factor: 2.199

10.  The Oxford unicompartmental knee prosthesis: a 2-14 year follow-up.

Authors:  R Verdonk; D Cottenie; K F Almqvist; P Vorlat
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-05-28       Impact factor: 4.342

View more
  2 in total

1.  A Morphometric Fixed-Bearing Unicompartmental Knee Arthroplasty Can Reproduce Normal Knee Kinematics. An In Vitro Robotic Evaluation.

Authors:  Marc Bandi; Francesco Benazzo; Cécile Batailler; Iris Blatter; Eik Siggelkow; Sébastien Parratte
Journal:  Arthroplast Today       Date:  2022-06-17

2.  Wear Morphology on the Surfaces of CoCrMo Unicompartmental Knee Joint Endoprostheses as Elements of Metal-Metal Friction Nodes.

Authors:  Arkadiusz Szarek; Grzegorz Stradomski; Justyna Łukomska-Szarek; Dariusz Rydz; Wojciech Wolański; Kamil Joszko
Journal:  Materials (Basel)       Date:  2020-06-12       Impact factor: 3.623

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.