Literature DB >> 11293735

The effect of implantation of aortic stents on compliance and blood flow. An experimental study in pigs.

J Pihkala1, G K Thyagarajan, G P Taylor, D Nykanen, L N Benson.   

Abstract

Balloon dilation of coarctation of the aorta has been found to be an effective modality for treatment. Recently, in the older child and adult, implantation of endovascular stents has been considered a clinical alternative to dilation alone. Little is known, however, of the effect of implantation of stents on aortic compliance. To investigate this impact of implantation, we studied 18 piglets, divided into experimental and control groups. At median weight of 14 kg, 2 pairs of ultrasonic crystals were implanted on the aortic wall. After 1 week, all animals underwent catheterization. In the experimental group, a 3 cm long balloon expandable stent was implanted in the descending thoracic aorta between the pairs of crystals. Measurements of arterial pressure and dimensions were performed before implantation and immediately thereafter, and at follow-up catheterization. The index of stiffness, beta, and the the elastic modulus of aortic pressure-strain, were calculated as indexes of arterial compliance. The change in compliance during the period of study was not different between groups. At follow-up, no difference was observed between groups in the velocity of the aortic pulse wave, the augmentation index, or the maximum velocity of flow of blood. The stents remained patent and did not affect aortic growth or medial wall thickness. There was no difference between groups in levels of plasma renin activity and serum aldosterone. In this animal model studied over the short term, therefore, implantation of stents does not affect aortic compliance. Further studies are required to elucidate the long term effects of stents on the hemodynamics affecting the aortic wall and local flow dynamics.

Entities:  

Mesh:

Year:  2001        PMID: 11293735     DOI: 10.1017/s1047951101000075

Source DB:  PubMed          Journal:  Cardiol Young        ISSN: 1047-9511            Impact factor:   1.093


  6 in total

1.  Coarctation of the aorta in adults: do we need surgeons?

Authors:  M J Mullen
Journal:  Heart       Date:  2003-01       Impact factor: 5.994

2.  Stenting of hypoplastic aortic segments with mild pressure gradients and arterial hypertension.

Authors:  D Boshoff; W Budts; L Mertens; B Eyskens; T Delhaas; B Meyns; W Daenen; M Gewillig
Journal:  Heart       Date:  2006-04-27       Impact factor: 5.994

3.  Effects of stent implantation for peripheral pulmonary artery stenosis on pulmonary vascular hemodynamics and right ventricular function in a patient with repaired tetralogy of Fallot.

Authors:  Kaduki Khono; Akiko Tamai; Toshiki Kobayashi; Hideaki Senzaki
Journal:  Heart Vessels       Date:  2011-03-18       Impact factor: 2.037

4.  Impaired poststenotic aortic pulsatility after hemodynamically ideal coarctation repair in children.

Authors:  J-P Pfammatter; P Berdat; T Carrel
Journal:  Pediatr Cardiol       Date:  2004-05-12       Impact factor: 1.655

5.  Differential impact of local stiffening and narrowing on hemodynamics in repaired aortic coarctation: an FSI study.

Authors:  Liesbeth Taelman; Joris Bols; Joris Degroote; Vivek Muthurangu; Joseph Panzer; Jan Vierendeels; Patrick Segers
Journal:  Med Biol Eng Comput       Date:  2015-07-05       Impact factor: 2.602

6.  Pulsatility index in aortic coarctation: a possible way to evaluate factors affecting stenting outcome.

Authors:  Shokoufeh Hajsadeghi; Seyed-Mohammad Fereshtehnejad; Saeid Gholami; Mitra Chitsazan; Mohammad Reza Keramati
Journal:  J Tehran Heart Cent       Date:  2012-02-28
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.