Literature DB >> 15128989

Small pulmonary nodules: reproducibility of three-dimensional volumetric measurement and estimation of time to follow-up CT.

William J Kostis1, David F Yankelevitz, Anthony P Reeves, Simina C Fluture, Claudia I Henschke.   

Abstract

PURPOSE: To determine reproducibility of volume measurements of small pulmonary nodules on computed tomographic (CT) scans and to estimate critical time to follow-up CT.
MATERIALS AND METHODS: One hundred fifteen pulmonary nodules for which two thin-section small-field-of-view CT scans were obtained and which were stable during 2-year observation were evaluated. A standard group of 94 nodules (with no or minimal artifact) and an expanded group of 105 nodules (including those with moderate artifacts) were examined. Percentage volume change (PVC) and monthly volumetric growth index (MVGI) were computed for each nodule pair. By using estimates of the variation in PVC in stable nodules as a function of initial diameter, critical time to follow-up CT was estimated; this time is the earliest point at which growth in a nodule of a given size can be reliably identified with repeat CT.
RESULTS: The SD of PVC decreased with increasing nodule size from 18.5% in 2-5-mm nodules to 10.6% in 5-8-mm nodules and to 7.47% in 8-10-mm nodules. Inclusion of cases with moderate motion artifacts increased the SD of PVC to 27.4% in 2-5-mm nodules, to 17.1% in 5-8-mm nodules, and to 19.3% in 8-10-mm nodules. Critical time to follow-up CT for nodules detected at baseline screening was 12, 5, and 3 months and 1 month for those with initial sizes of 2, 5, 8, and 10 mm, respectively. For nodules detected at annual repeat screening, it was 4 and 3 months and 1 month for nodules that were 3, 4, and 5 mm or larger in size, respectively. Mean MVGI in 94 standard cases was 0.06%, and standard error was 0.21%.
CONCLUSION: Factors that affect reproducibility of nodule volume measurements and critical time to follow-up CT include nodule size at detection, type of scan (baseline or annual repeat) on which the nodule is detected, and presence of patient-induced artifacts.

Entities:  

Mesh:

Year:  2004        PMID: 15128989     DOI: 10.1148/radiol.2312030553

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  53 in total

Review 1.  Imaging of lung cancer in the era of molecular medicine.

Authors:  Mizuki Nishino; David M Jackman; Hiroto Hatabu; Pasi A Jänne; Bruce E Johnson; Annick D Van den Abbeele
Journal:  Acad Radiol       Date:  2011-01-28       Impact factor: 3.173

2.  CT tumor volume measurement in advanced non-small-cell lung cancer: Performance characteristics of an emerging clinical tool.

Authors:  Mizuki Nishino; Mengye Guo; David M Jackman; Pamela J DiPiro; Jeffrey T Yap; Tak K Ho; Hiroto Hatabu; Pasi A Jänne; Annick D Van den Abbeele; Bruce E Johnson
Journal:  Acad Radiol       Date:  2010-10-30       Impact factor: 3.173

3.  Insertion of virtual pulmonary nodules in CT data of the chest: development of a software tool.

Authors:  Hoen-oh Shin; Matthias Blietz; Bernd Frericks; Stefan Baus; Dagmar Savellano; Michael Galanski
Journal:  Eur Radiol       Date:  2006-07-04       Impact factor: 5.315

4.  Effect of blood vessels on measurement of nodule volume in a chest phantom.

Authors:  Jane P Ko; Rachel Marcus; Elan Bomsztyk; James S Babb; Cornel Stefanescu; Manmeen Kaur; David P Naidich; Henry Rusinek
Journal:  Radiology       Date:  2006-04       Impact factor: 11.105

Review 5.  Management of an incidentally discovered pulmonary nodule.

Authors:  Catherine Beigelman-Aubry; Catherine Hill; Philippe A Grenier
Journal:  Eur Radiol       Date:  2006-10-05       Impact factor: 5.315

Review 6.  Noncalcified lung nodules: volumetric assessment with thoracic CT.

Authors:  Marios A Gavrielides; Lisa M Kinnard; Kyle J Myers; Nicholas Petrick
Journal:  Radiology       Date:  2009-04       Impact factor: 11.105

7.  Imprecision in automated volume measurements of pulmonary nodules and its effect on the level of uncertainty in volume doubling time estimation.

Authors:  Paul J Nietert; James G Ravenel; William M Leue; James V Miller; Katherine K Taylor; Elizabeth S Garrett-Mayer; Gerard A Silvestri
Journal:  Chest       Date:  2009-01-13       Impact factor: 9.410

8.  A comparison of six software packages for evaluation of solid lung nodules using semi-automated volumetry: what is the minimum increase in size to detect growth in repeated CT examinations.

Authors:  Bartjan de Hoop; Hester Gietema; Bram van Ginneken; Pieter Zanen; Gerard Groenewegen; Mathias Prokop
Journal:  Eur Radiol       Date:  2008-11-19       Impact factor: 5.315

Review 9.  Screening for lung cancer with low-dose computed tomography: a review of current status.

Authors:  Henry M Marshall; Rayleen V Bowman; Ian A Yang; Kwun M Fong; Christine D Berg
Journal:  J Thorac Dis       Date:  2013-10       Impact factor: 2.895

Review 10.  The importance of the regimen of screening in maximizing the benefit and minimizing the harms.

Authors:  Claudia I Henschke; Kunwei Li; Rowena Yip; Mary Salvatore; David F Yankelevitz
Journal:  Ann Transl Med       Date:  2016-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.