Literature DB >> 15122687

Reduced RF power without blurring: correcting for modulation of refocusing flip angle in FSE sequences.

Reed F Busse1.   

Abstract

In order to reduce the RF power deposition of fast spin echo sequences operated at high field strength, the flip angles of the refocusing pulse train are varied from pulse to pulse using a modulated angle refocusing train method. The technique employs high flip angle pulses prior to sampling the center of k-space in order to preserve T(2) contrast, low flip angles after sampling the center of k-space to reduce power and prolong relaxation, and a smooth transition between the high and low flip angle regimes in order to maintain the pseudosteady-state, maximizing signal and avoiding artifact-inducing oscillations. An analytical expression is used to predict and correct for the flip angle dependence of the signal, thus eliminating any deleterious effects of flip angle modulation on the point spread function. Analysis of resolution and SNR were performed in simulation and phantom studies. In human imaging studies, it is shown that RF energy deposition per slice in a single-shot fast spin echo application can be reduced by up to 75%, making the sequence as practical at 3 T as it is has been at 1.5 T. Copyright 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2004        PMID: 15122687     DOI: 10.1002/mrm.20056

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  15 in total

1.  Multi-parametric neuroimaging reproducibility: a 3-T resource study.

Authors:  Bennett A Landman; Alan J Huang; Aliya Gifford; Deepti S Vikram; Issel Anne L Lim; Jonathan A D Farrell; John A Bogovic; Jun Hua; Min Chen; Samson Jarso; Seth A Smith; Suresh Joel; Susumu Mori; James J Pekar; Peter B Barker; Jerry L Prince; Peter C M van Zijl
Journal:  Neuroimage       Date:  2010-11-20       Impact factor: 6.556

Review 2.  Muskuloskeletal MR imaging at 3.0 T: current status and future perspectives.

Authors:  Nicolae Bolog; Daniel Nanz; Dominik Weishaupt
Journal:  Eur Radiol       Date:  2006-03-16       Impact factor: 5.315

3.  Hyperecho-turbo spin-echo sequences at 3T: clinical application in neuroradiology.

Authors:  R H Tetzlaff; I Mader; W Küker; J Weber; S Ziyeh; A Schulze-Bonhage; J Hennig; M Weigel
Journal:  AJNR Am J Neuroradiol       Date:  2008-03-05       Impact factor: 3.825

Review 4.  Cardiac magnetic resonance at high field: promises and problems.

Authors:  Ahmed M Gharib; Abdalla Elagha; Roderic I Pettigrew
Journal:  Curr Probl Diagn Radiol       Date:  2008 Mar-Apr

5.  Variable Refocusing Flip Angle Single-Shot Imaging for Sedation-Free Fast Brain MRI.

Authors:  R Jabarkheel; E Tong; E H Lee; T M Cullen; U Yousaf; A M Loening; V Taviani; M Iv; G A Grant; S J Holdsworth; S S Vasanawala; K W Yeom
Journal:  AJNR Am J Neuroradiol       Date:  2020-06-25       Impact factor: 3.825

6.  Controlling T2 blurring in 3D RARE arterial spin labeling acquisition through optimal combination of variable flip angles and k-space filtering.

Authors:  Li Zhao; Ching-Di Chang; David C Alsop
Journal:  Magn Reson Med       Date:  2018-02-09       Impact factor: 4.668

Review 7.  Magnetic Resonance Imaging of the Liver (Including Biliary Contrast Agents) Part 1: Technical Considerations and Contrast Materials.

Authors:  A Agostini; M F Kircher; R Do; A Borgheresi; S Monti; A Giovagnoni; L Mannelli
Journal:  Semin Roentgenol       Date:  2016-05-30       Impact factor: 0.800

8.  3D fast spin echo with out-of-slab cancellation: a technique for high-resolution structural imaging of trabecular bone at 7 Tesla.

Authors:  Jeremy F Magland; Chamith S Rajapakse; Alexander C Wright; Raymond Acciavatti; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2010-03       Impact factor: 4.668

9.  Faster pediatric 3-T abdominal magnetic resonance imaging: comparison between conventional and variable refocusing flip-angle single-shot fast spin-echo sequences.

Authors:  Nichanan Ruangwattanapaisarn; Andreas M Loening; Manojkumar Saranathan; Daniel V Litwiller; Shreyas S Vasanawala
Journal:  Pediatr Radiol       Date:  2014-11-30

10.  Fetal MRI: A Technical Update with Educational Aspirations.

Authors:  Ali Gholipour; Judith A Estroff; Carol E Barnewolt; Richard L Robertson; P Ellen Grant; Borjan Gagoski; Simon K Warfield; Onur Afacan; Susan A Connolly; Jeffrey J Neil; Adam Wolfberg; Robert V Mulkern
Journal:  Concepts Magn Reson Part A Bridg Educ Res       Date:  2014-11       Impact factor: 0.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.