Literature DB >> 15120009

Comparison of two budesonide dry powder inhalers in the treatment of asthma in children.

T Vanto1, K M Hämäläinen, M Vahteristo, S Wille, F Njå, N Hyldebrandt.   

Abstract

The aim of this study was to compare the clinical efficacy, safety, and acceptability of budesonide inhaled from Easyhaler dry powder inhaler (DPI) (Giona Easyhaler, Orion Pharma, Finland) and from Turbuhaler DPI (Pulmicort Turbuhaler, AstraZeneca, Sweden) in the treatment of asthma in children. The 6-month, randomised, double-blind, double-dummy, parallel-group study was conducted in 229 completed, asthmatic children (5-10 years), who were symptomatic at study entry. For the first 2 months, children inhaled budesonide 2 x 200 microg b.i.d. (high-dose treatment period). Thereafter, the daily dose of inhaled budesonide was 2 x 100 microg for 4 months (low-dose treatment period). The study was carried out at 32 centers in Finland, Sweden, Norway, and Denmark. During the high-dose treatment period, the initially symptomatic patients improved in both treatment groups and the achieved control was maintained during the low-dose treatment period. An improvement was seen in the efficacy outcome parameters in the initially symptomatic patients in both treatment groups. Also, there were no differences in the number of asthma exacerbations between the treatments. The urinary free cortisol/creatinine (UCC) ratios were significantly lower in the Turbuhaler group compared to the Easyhaler group after the high-dose treatment period. In addition, there was a slight but statistically significant slower growth rate in the Turbuhaler group after the 6- month treatment period compared with the Easyhaler group. Pulmicort Turbuhaler and Giona Easyhaler are equally effective in the treatment of asthma in children aged 5-10 years old. Budesonide inhaled from Turbuhaler showed slightly greater systemic effects than budesonide inhaled from Easyhaler. The majority of children and parents preferred Easyhaler to Turbuhaler.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15120009     DOI: 10.1089/089426804322994424

Source DB:  PubMed          Journal:  J Aerosol Med        ISSN: 0894-2684


  9 in total

1.  Inhaled corticosteroids in children with persistent asthma: effects of different drugs and delivery devices on growth.

Authors:  Inge Axelsson; Estelle Naumburg; Sílvio Om Prietsch; Linjie Zhang
Journal:  Cochrane Database Syst Rev       Date:  2019-06-10

2.  Equivalent lung deposition of budesonide in vivo: a comparison of dry powder inhalers using a pharmacokinetic method.

Authors:  Satu Lähelmä; Merja Kirjavainen; Marjo Kela; Jukka Herttuainen; Mikko Vahteristo; Matti Silvasti; Marjut Ranki-Pesonen
Journal:  Br J Clin Pharmacol       Date:  2005-02       Impact factor: 4.335

Review 3.  Closer to an 'ideal inhaler' with the Easyhaler: an innovative dry powder inhaler.

Authors:  Henry Chrystyn
Journal:  Clin Drug Investig       Date:  2006       Impact factor: 2.859

4.  In Vitro Flow Rate Dependency of Delivered Dose and Fine Particle Dose of Salmeterol/Fluticasone Propionate Easyhaler and Seretide Diskus with Patient Flow Rates Collected in a Randomized Controlled Trial.

Authors:  Rain Jõgi; Satu Lähelmä; Mikko Vahteristo; Anita Happonen; Jussi Haikarainen
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2018-10-09       Impact factor: 2.849

Review 5.  The Diskus: a review of its position among dry powder inhaler devices.

Authors:  H Chrystyn
Journal:  Int J Clin Pract       Date:  2007-06       Impact factor: 2.503

6.  Inhaler competence and patient satisfaction with Easyhaler®: results of two real-life multicentre studies in asthma and COPD.

Authors:  Gabriella Gálffy; Györgyi Mezei; Gyula Németh; Lilla Tamási; Veronika Müller; Olof Selroos; Marta Orosz
Journal:  Drugs R D       Date:  2013-09

7.  Switching patients from other inhaled corticosteroid devices to the Easyhaler(®): historical, matched-cohort study of real-life asthma patients.

Authors:  David Price; Vicky Thomas; Julie von Ziegenweidt; Shuna Gould; Catherine Hutton; Christine King
Journal:  J Asthma Allergy       Date:  2014-04-10

8.  Dose uniformity of budesonide Easyhaler® under simulated real-life conditions and with low inspiration flow rates.

Authors:  Jussi Haikarainen; Paula Rytilä; Sirkku Roos; Sirpa Metsärinne; Anita Happonen
Journal:  Chron Respir Dis       Date:  2017-12-07       Impact factor: 2.444

9.  A non-interventional switch study in adult patients with asthma or COPD on clinical effectiveness of salmeterol/fluticasone Easyhaler® in routine clinical practice.

Authors:  Ines Vinge; Jörgen Syk; Athanasios Xanthopoulos; Hendrik Laßmann; Mikko Vahteristo; Ulla Sairanen; Satu Lähelmä; Rudolf Hennig; Matthias Müller
Journal:  Ther Adv Respir Dis       Date:  2021 Jan-Dec       Impact factor: 4.031

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.