Literature DB >> 15111590

A new noninvasive tear stability analysis system for the assessment of dry eyes.

Takashi Kojima1, Reiko Ishida, Murat Dogru, Eiki Goto, Yoji Takano, Yukihiro Matsumoto, Minako Kaido, Yuichi Ohashi, Kazuo Tsubota.   

Abstract

PURPOSE: This was a prospective case-control study conducted to evaluate the effectiveness of the Tear Stability Analysis System (TSAS) for the assessment of patients with dry eye.
METHODS: The TSAS can take 10 consecutive corneal topograms at one per second for 10 seconds. Examinations using the TSAS were conducted in 26 eyes of 26 healthy control subjects and in 27 eyes of 27 patients with dry eye. Examinations were also conducted in 14 eyes of 14 patients before and after the insertion of punctum plugs. Surface regularity and asymmetry indices (SRI, SAI), as well as new tear stability regularity and asymmetry indices (TSRI, TSAI), derived from SRI and SAI, were analyzed.
RESULTS: The mean SRI and SAI in dry eyes were significantly greater than in control eyes (P < 0.05). The time-wise change of SRI and SAI was significantly different between dry eyes and control eyes (P < 0.05). TSRI and TSAI in dry eyes were also significantly greater than in control eyes. Punctum plug insertion was associated with a significant decrease in SRI and SAI (P < 0.05).
CONCLUSIONS: TSAS was effective in objectively assessing the tear stability in patients with dry eye. This system may be useful in noninvasive diagnosis of dry eye and evaluation of treatment effects.

Entities:  

Mesh:

Year:  2004        PMID: 15111590     DOI: 10.1167/iovs.03-0712

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  23 in total

1.  Optical quality of the eye degraded by time-varying wavefront aberrations with tear film dynamics.

Authors:  Yoko Hirohara; Toshifumi Mihashi; Shizuka Koh; Sayuri Ninomiya; Naoyuki Maeda; Takashi Fujikado
Journal:  Jpn J Ophthalmol       Date:  2007-08-03       Impact factor: 2.447

2.  Measurement of the time course of optical quality and visual deterioration during tear break-up.

Authors:  Haixia Liu; Larry Thibos; Carolyn G Begley; Arthur Bradley
Journal:  Invest Ophthalmol Vis Sci       Date:  2010-01-27       Impact factor: 4.799

Review 3.  Dynamics and function of the tear film in relation to the blink cycle.

Authors:  R J Braun; P E King-Smith; C G Begley; Longfei Li; N R Gewecke
Journal:  Prog Retin Eye Res       Date:  2014-12-03       Impact factor: 21.198

4.  Dry eye evaluation and correlation analysis between tear film stability and corneal surface regularity after small incision lenticule extraction.

Authors:  Hui Zhang; Yan Wang
Journal:  Int Ophthalmol       Date:  2017-09-22       Impact factor: 2.031

Review 5.  Biological functions of tear film.

Authors:  Stephen C Pflugfelder; Michael E Stern
Journal:  Exp Eye Res       Date:  2020-06-16       Impact factor: 3.467

6.  The relation of functional visual acuity measurement methodology to tear functions and ocular surface status.

Authors:  Minako Kaido; Reiko Ishida; Murat Dogru; Kazuo Tsubota
Journal:  Jpn J Ophthalmol       Date:  2011-06-30       Impact factor: 2.447

7.  Association between clinical diagnostic tests and health-related quality of life surveys in patients with dry eye syndrome.

Authors:  Yoshinobu Mizuno; Masakazu Yamada; Yozo Miyake
Journal:  Jpn J Ophthalmol       Date:  2010-08-11       Impact factor: 2.447

Review 8.  [Blinking activity during visual display terminal work. Part 1: Ocular discomfort and pathophysiological principles].

Authors:  F Ziemssen; N Freudenthaler; K Regnery; T Schlote
Journal:  Ophthalmologe       Date:  2005-08       Impact factor: 1.059

9.  Concordance between common dry eye diagnostic tests.

Authors:  J E Moore; J E Graham; E A Goodall; D A Dartt; A Leccisotti; V E McGilligan; T C B Moore
Journal:  Br J Ophthalmol       Date:  2008-09-09       Impact factor: 4.638

10.  Non-invasive assessment of tear film stability with a novel corneal topographer in Indian subjects.

Authors:  Vipul Bhandari; Jagdeesh K Reddy; Kirti Relekar; Ameya Ingawale; Neeraj Shah
Journal:  Int Ophthalmol       Date:  2016-02-18       Impact factor: 2.031

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.