Literature DB >> 15104007

The PSI Gantry 2: a second generation proton scanning gantry.

Eros Pedroni1, Ralph Bearpark, Terence Böhringer, Adolf Coray, Jürgen Duppich, Sven Forss, David George, Martin Grossmann, Gudrun Goitein, Christian Hilbes, Martin Jermann, Shixiong Lin, Antony Lomax, Marco Negrazus, Marco Schippers, Goran Kotle.   

Abstract

PSI is still the only location in which proton therapy is applied using a dynamic beam scanning technique on a very compact gantry. Recently, this system is also being used for the application of intensity-modulated proton therapy (IMPT). This novel technical development and the success of the proton therapy project altogether have led PSI in Year 2000 to further expand the activities in this field by launching the project PROSCAN. The first step is the installation of a dedicated commercial superconducting cyclotron of a novel type. The second step is the development of a new gantry, Gantry 2. For Gantry 2 we have chosen an iso-centric compact gantry layout. The diameter of the gantry is limited to 7.5 m, less than in other gantry systems (approximately 10-12 m). The space in the treatment room is comfortably large, and the access on a fixed floor is possible any time around the patient table. Through the availability of a faster scanning system, it will be possible to treat the target volume repeatedly in the same session. For this purpose, the dynamic control of the beam intensity at the ion source and the dynamic variation of the beam energy will be used directly for the shaping of the dose.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15104007     DOI: 10.1078/0939-3889-00194

Source DB:  PubMed          Journal:  Z Med Phys        ISSN: 0939-3889            Impact factor:   4.820


  15 in total

1.  Adjustment of the lateral and longitudinal size of scanned proton beam spots using a pre-absorber to optimize penumbrae and delivery efficiency.

Authors:  Uwe Titt; Dragan Mirkovic; Gabriel O Sawakuchi; Luis A Perles; Wayne D Newhauser; Phillip J Taddei; Radhe Mohan
Journal:  Phys Med Biol       Date:  2010-11-12       Impact factor: 3.609

Review 2.  Image guidance in proton therapy for lung cancer.

Authors:  Miao Zhang; Wei Zou; Boon-Keng Kevin Teo
Journal:  Transl Lung Cancer Res       Date:  2018-04

Review 3.  Proton therapy delivery: what is needed in the next ten years?

Authors:  Andries N Schreuder; Jacob Shamblin
Journal:  Br J Radiol       Date:  2019-11-14       Impact factor: 3.039

Review 4.  Particle therapy of moving targets-the strategies for tumour motion monitoring and moving targets irradiation.

Authors:  Tomasz Kubiak
Journal:  Br J Radiol       Date:  2016-07-19       Impact factor: 3.039

5.  Stray radiation dose and second cancer risk for a pediatric patient receiving craniospinal irradiation with proton beams.

Authors:  Phillip J Taddei; Dragan Mirkovic; Jonas D Fontenot; Annelise Giebeler; Yuanshui Zheng; David Kornguth; Radhe Mohan; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2009-03-20       Impact factor: 3.609

6.  Technical advances and pitfalls in head and neck radiotherapy.

Authors:  Upendra Parvathaneni; George E Laramore; Jay J Liao
Journal:  J Oncol       Date:  2012-05-30       Impact factor: 4.375

7.  Reducing the cost of proton radiation therapy: the feasibility of a streamlined treatment technique for prostate cancer.

Authors:  Wayne D Newhauser; Rui Zhang; Timothy G Jones; Annelise Giebeler; Phillip J Taddei; Robert D Stewart; Andrew Lee; Oleg Vassiliev
Journal:  Cancers (Basel)       Date:  2015-04-24       Impact factor: 6.639

8.  4D treatment planning for scanned ion beams.

Authors:  Christoph Bert; Eike Rietzel
Journal:  Radiat Oncol       Date:  2007-07-03       Impact factor: 3.481

Review 9.  Roadmap: proton therapy physics and biology.

Authors:  Harald Paganetti; Chris Beltran; Stefan Both; Lei Dong; Jacob Flanz; Keith Furutani; Clemens Grassberger; David R Grosshans; Antje-Christin Knopf; Johannes A Langendijk; Hakan Nystrom; Katia Parodi; Bas W Raaymakers; Christian Richter; Gabriel O Sawakuchi; Marco Schippers; Simona F Shaitelman; B K Kevin Teo; Jan Unkelbach; Patrick Wohlfahrt; Tony Lomax
Journal:  Phys Med Biol       Date:  2021-02-26       Impact factor: 4.174

10.  Scanned Proton Beam Performance and Calibration of the Shanghai Advanced Proton Therapy Facility.

Authors:  Hang Shu; Chongxian Yin; Haiyang Zhang; Ming Liu; Manzhou Zhang; Liying Zhao; Kecheng Chu; Xiaolei Dai; Michael F Moyers
Journal:  MethodsX       Date:  2019-08-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.