Literature DB >> 15090279

Prostate gland motion and deformation caused by needle placement during brachytherapy.

Nelson N Stone1, Jiten Roy, Suzanne Hong, Yeh-Chi Lo, Richard G Stock.   

Abstract

PURPOSE: To determine the extent of edge and gland position changes caused by needle insertion in patients undergoing prostate brachytherapy. METHODS AND MATERIALS: Nineteen patients with T1-T3 prostate cancer were implanted with the real-time method by using a two-phase peripheral loading technique. Serial contours of the prostate at 5-mm intervals were acquired by the dose-planning system. All of the peripheral needles were then placed and spaced 5-10 mm apart by using the largest transverse ultrasound image as the reference plane. The position of the probe was relocated at the zero plane, and the difference between the preneedle and postneedle zero plane was recorded as the difference in the z axis. Axial ultrasound images were again acquired. The second set of captured images, which matched in number the first set, was contoured over the previously contoured preneedle images. Prostate gland deformation and displacement were determined by comparing the preneedle contoured image with the images captured after needle placement. Deformation was determined by calculating the differences between the edges of the gland as measured at the major axis of the gland (x and y planes). Displacement was determined by measuring the differences between the center positions of the two contoured structures. Deformation and displacement were determined on each acquired 5-mm image. Differences were compared by student's t test.
RESULTS: The mean preneedle prostate volume was 47 ml (range, 21.5-68.7 ml), compared with 48.1 ml (range, 19.4-80.3 ml; p = 0.228) after peripheral needle placement. A median of 16 (range, 12-19) peripheral needles were placed. The median change in the base position of the prostate was 1.5 cm (range of 0 to 3.0 cm; p = 0.0034). The mean x and y deformation was 6.8 mm (median, 7.9 mm; range, 4.3-8.1 mm) and 3.6 mm (median, 3.3 mm; range, 1.0-5.5 mm), respectively. The greatest deformation for any individual slice for x was 21.6 mm and for y was 15.3 mm. The mean number of slices that were found with a >2-, 5-, and 10-mm deformation in the x axis was 7 (range, 3-10), 4 (range, 1-3), and 1 (range, 0-4), respectively. Similar deformation in the y axis was found in 6 (range, 3-10), 2.5 (range, 0-6), and 0.3 (range, 0-2) slices. The mean x and y displacement was 1.9 mm (median, 1.8 mm; range, 0.3-6.6 mm) and 2.8 mm (median, 1.9 mm; range, 2-5.8 mm). The greatest displacement for any individual slice for x was 7 mm and for y was 10 mm. The mean number of slices with a displacement >2, 5, and 10 mm in the x axis was 5 (range, 1-10), 0.8 (range, 0-5), and 0, respectively. Similar displacement in the y axis was found in 5 (range, 0-9), 1.7 (range, 0-7), and 0 slices, respectively.
CONCLUSIONS: Placing most needles in the periphery results in a minimal prostate volume increase, suggesting little need to overplan the implant when this method is used. However, significant edge and gland position changes caused by the needle insertion did occur. These changes may explain some of the difficulty in reproducing the preplan and should be taken into consideration for all types of prostate brachytherapy planning.

Entities:  

Mesh:

Year:  2002        PMID: 15090279     DOI: 10.1016/s1538-4721(02)00058-2

Source DB:  PubMed          Journal:  Brachytherapy        ISSN: 1538-4721            Impact factor:   2.362


  9 in total

1.  Design of an Optically Controlled MR-Compatible Active Needle.

Authors:  Seok Chang Ryu; Zhan Fan Quek; Je-Sung Koh; Pierre Renaud; Richard J Black; Behzad Moslehi; Bruce L Daniel; Kyu-Jin Cho; Mark R Cutkosky
Journal:  IEEE Trans Robot       Date:  2015-02       Impact factor: 5.567

2.  Advantage of robotic needle placement on a prostate model in HDR brachytherapy.

Authors:  Gerd Strassmann; Peter Olbert; Axel Hegele; Detlev Richter; Emmanouil Fokas; Nina Timmesfeld; Rainer Hofmann; Rita Engenhart-Cabillic
Journal:  Strahlenther Onkol       Date:  2011-05-17       Impact factor: 3.621

3.  MR imaging-guided prostate biopsy: technical features and preliminary results.

Authors:  Valeria Panebianco; Flavio Barchetti; Guglielmo Manenti; Tommaso Aversa; Carlo Catalano; Giovanni Simonetti
Journal:  Radiol Med       Date:  2015-01-13       Impact factor: 3.469

4.  Brachytherapy for prostate cancer: a systematic review.

Authors:  Georgios Koukourakis; Nikolaos Kelekis; Vassilios Armonis; Vassilios Kouloulias
Journal:  Adv Urol       Date:  2009-09-01

5.  Prostate biopsies assisted by comanipulated probe-holder: first in man.

Authors:  Marie-Aude Vitrani; Michael Baumann; David Reversat; Guillaume Morel; Alexandre Moreau-Gaudry; Pierre Mozer
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-04-12       Impact factor: 2.924

Review 6.  Three-dimensional conformal brachytherapy for prostate cancer.

Authors:  Michael J Zelefsky
Journal:  Curr Urol Rep       Date:  2004-06       Impact factor: 2.862

7.  Evaluation of a robotic technique for transrectal MRI-guided prostate biopsies.

Authors:  Martijn G Schouten; Joyce G R Bomers; Derya Yakar; Henkjan Huisman; Eva Rothgang; Dennis Bosboom; Tom W J Scheenen; Sarthak Misra; Jurgen J Fütterer
Journal:  Eur Radiol       Date:  2011-09-29       Impact factor: 5.315

8.  Method to Reduce Target Motion Through Needle-Tissue Interactions.

Authors:  Matthew J Oldfield; Alexander Leibinger; Tian En Timothy Seah; Ferdinando Rodriguez Y Baena
Journal:  Ann Biomed Eng       Date:  2015-05-06       Impact factor: 3.934

9.  Axially rigid steerable needle with compliant active tip control.

Authors:  M de Vries; J Sikorski; S Misra; J J van den Dobbelsteen
Journal:  PLoS One       Date:  2021-12-16       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.