Stephen P Povoski1. 1. Division of Surgical Oncology, Department of Surgery, Arthur G, James Cancer Hospital and Richard J, Solove Research Institute, The Ohio State University, Columbus, Ohio 43210-1228, USA. povoski-1@medctr.osu.edu
Abstract
BACKGROUND: Cephalic vein (CV) cutdown approach for chronic indwelling central venous access device (CICVAD) placement has previously been shown to be technically feasible in 82% of cancer patients. No data are available as to the potential utilization of external jugular vein (EJV) cutdown approach in cancer patients when CV cutdown approach is not technically feasible. PATIENTS AND METHODS: One hundred and twenty consecutive cancer patients were taken to the operating room with the intention of placing a CICVAD. All patients were first subjected to attempted CV cutdown approach. If CV cutdown approach was unsuccessful and there were no contraindications to establishing central venous access in the ipsilateral neck region, an ipsilateral EJV cutdown approach was attempted. RESULTS: Ninety-five cancer patients (79%) underwent CICVAD placement via CV cutdown. Of those 25 patients in which CV cutdown was not technically feasible, 7 had a contraindication to establishing central venous access in the ipsilateral neck region and a CICVAD was placed via the ipsilateral subclavian vein percutaneous approach. Of those remaining 18 patients in which CV cutdown approach was not technically feasible, 17 (94%) underwent CICVAD placement via ipsilateral EJV cutdown approach. Combined success of the CV and EJV cutdown approaches, excluding those 7 patients with a contraindication to central venous access in the ipsilateral neck region, was greater than 99%. CONCLUSIONS: Venous cutdown approaches for CICVAD placement are viable alternatives to subclavian vein percutaneous approach in cancer patients. EJV cutdown approach appears to be a highly successful and safe alternative route when CV cutdown approach is not technically feasible and may be considered a potentially useful primary route for CICVAD placement in cancer patients.
BACKGROUND:Cephalic vein (CV) cutdown approach for chronic indwelling central venous access device (CICVAD) placement has previously been shown to be technically feasible in 82% of cancerpatients. No data are available as to the potential utilization of external jugular vein (EJV) cutdown approach in cancerpatients when CV cutdown approach is not technically feasible. PATIENTS AND METHODS: One hundred and twenty consecutive cancerpatients were taken to the operating room with the intention of placing a CICVAD. All patients were first subjected to attempted CV cutdown approach. If CV cutdown approach was unsuccessful and there were no contraindications to establishing central venous access in the ipsilateral neck region, an ipsilateral EJV cutdown approach was attempted. RESULTS: Ninety-five cancerpatients (79%) underwent CICVAD placement via CV cutdown. Of those 25 patients in which CV cutdown was not technically feasible, 7 had a contraindication to establishing central venous access in the ipsilateral neck region and a CICVAD was placed via the ipsilateral subclavian vein percutaneous approach. Of those remaining 18 patients in which CV cutdown approach was not technically feasible, 17 (94%) underwent CICVAD placement via ipsilateral EJV cutdown approach. Combined success of the CV and EJV cutdown approaches, excluding those 7 patients with a contraindication to central venous access in the ipsilateral neck region, was greater than 99%. CONCLUSIONS: Venous cutdown approaches for CICVAD placement are viable alternatives to subclavian vein percutaneous approach in cancerpatients. EJV cutdown approach appears to be a highly successful and safe alternative route when CV cutdown approach is not technically feasible and may be considered a potentially useful primary route for CICVAD placement in cancerpatients.
The vast majority of chronic indwelling central venous access devices (CICVAD) are placed in cancerpatients by the subclavian vein percutaneous approach [1]. Venous cutdown approaches can be useful alternatives; however, they appear to be infrequently utilized. The cephalic vein (CV) cutdown approach has been previously shown to be technically feasible in 82% of cancerpatients [2]. Likewise, the external jugular vein (EJV) cutdown approach has been previously shown to be technically feasible in 88% of cancerpatients [3]. Although the EJV cutdown approach for central venous access is well described in the literature [3-8], there is no data available which specifically addresses the question of the potential utilization of EJV cutdown approach for CICVAD placement in cancerpatients when the CV cutdown approach is not technically feasible. This question is specifically addressed in the present study.
Of the 120 consecutive patients taken to the operating room with the intention of placing a CICVAD, median patient age was 53 years (range 23–81), of which 72 were females and 48 were males. Thirty-one patients had breast cancer, 25 had gastrointestinal malignancies, 16 had leukemia, 15 had lymphoma, 8 had multiple myeloma, 7 had head/neck malignancies, 4 had lung cancer, and 14 had other malignancies. The procedure was performed utilizing monitored intravenous sedation and local anesthetic in 63 patients. Thirty-seven patients requested general anesthesia for the procedure and 18 patients required general anesthesia for the performance of another concurrent surgical procedures. Only 2 patient required conversion from monitored intravenous sedation to general anesthesia during the procedure. Eighty, BardPort® 9.6 French implanted ports, 31, Leonard® 10 French tunneled catheters, and 9 Hickman® 12 French tunneled catheters were placed. Median operating time for CICVAD placement for all the 120 consecutive patients was 48 minutes (range 23–210).Of the 120 consecutive patients taken to the operating room with the intention of placing a CICVAD, 95 patients (79%) underwent successful CICVAD placement via the CV cutdown approach and 25 patients (21%) did not. Median operating time for those 95 patients undergoing a successful CV cutdown approach was 45 minutes (range 23–84). Of the 25 patients in whom successful CICVAD placement via the CV cutdown approach was not technically feasible, 17 patients had too small CV thus making the catheter placement difficult and 8 patients had no detectable CV. Likewise, of those 25 patients in whom successful CICVAD placement via the CV cutdown approach was not technically feasible, 7 patients had a contraindication to establishing central venous access in the ipsilateral neck region. This included 2 patients with a history of carotid artery surgery, 2 with a newly diagnosed esophageal cancer requiring neoadjuvant chemotherapy, 1 with a history of neck surgery for a head/neck malignancy, 1 with a neck mass associated with a newly diagnosed head/neck malignancy requiring neoadjuvant chemotherapy, and 1 with adenopathy of the neck associated with metastatic breast cancer.Of those 18 patients in whom successful CICVAD placement via the CV cutdown approach was not technically feasible and in whom there was no contraindication to establishing central venous access in the ipsilateral neck region, 17 (94%) underwent successful CICVAD placement via the ipsilateral EJV cutdown approach. Median operating time for those 17 patients was 68 minutes (range 44–125). The single patient who failed both the CV cutdown approach and ipsilateral EVJ cutdown approach also failed the ipsilateral subclavian vein percutaneous approach. In this case, a CICVAD was eventually placed during the same operative setting by way of a contralateral CV cutdown approach.All of the 7 patients, in whom successful CICVAD placement via the CV cutdown approach was not technically feasible and in whom there was a contraindication to establishing central venous access in the ipsilateral neck region, successfully underwent CICVAD placement via the ipsilateral subclavian vein percutaneous approach. Median total operating time for those 7 patients was 68 minutes (range 34–210).The combined success the CV cutdown approach and the ipsilateral EJV cutdown approach for CICVAD placement, including those 7 patients with a contraindication to central venous access in the ipsilateral neck region after unsuccessful CV cutdown, was 93% (112 of 120 patients). The combined success the CV cutdown approach and the ipsilateral EJV cutdown approach for CICVAD placement, excluding those 7 patients with a contraindication to central venous access in the ipsilateral neck region after unsuccessful CV cutdown, was greater than 99% (112 of 113 patients).No instances of immediate postoperative complications, such as pneumothorax, hemothorax, or injury to great vessels, was seen in the group of patients undergoing successful CICVAD placement by way of the CV cutdown approach, by way of the ipsilateral EJV cutdown approach after unsuccessful CV cutdown approach, or by way of the ipsilateral subclavian vein percutaneous approach after unsuccessful CV cutdown approach. However, a single case of postoperative ipsilateral pneumothorax was recognized intraoperatively in a patient who failed the ipsilateral CV cutdown approach, failed the ipsilateral EVJ cutdown approach, and failed the ipsilateral subclavian vein percutaneous approach prior to successful CICVAD placement by way of the contralateral CV cutdown approach.
Discussion
Although most CICVAD are placed in cancerpatients by the subclavian vein percutaneous approach [1], venous cutdown approaches can be useful alternatives. In the present study, we specifically address the question of the potential utilization of EJV cutdown approach for CICVAD placement when the CV cutdown approach is not technically feasible.In the present study, the CV cutdown approach alone was successful in 79% of cases. These results for the CV cutdown approach are virtually identical to those previously published [2,10]. Additionally, the ipsilateral EJV cutdown approach, after an unsuccessful CV cutdown approach, was successful in 94% (17/18) of cases. These results for the EJV cutdown approach after an unsuccessful CV cutdown approach are also virtually identical to those previously published for utilization of the EJV approach alone [3]. Finally, the resultant combined success of the CV cutdown approach and of the ipsilateral EJV cutdown approach, excluding those patients with a contraindication to central venous access in the ipsilateral neck region after unsuccessful CV cutdown approach, was greater than 99% (112/113). Such an impressive success rate for venous cutdown approaches could virtually eliminates the need for consideration of the subclavian vein percutaneous approach for CICVAD placement in appropriately selected cancerpatients.Previous studies have shown that the subclavian vein percutaneous approach for CICVAD placement has a well-documented risk of pneumothorax in approximately 1% to 4% of cases [11-14]. In contrast, previous studies have shown an absence of immediate perioperative complications, including pneumothorax, for both the CV cutdown approach [2,10,15-18] and the EJV cutdown approach [3,16]. Further confirmation of this is demonstrated in the current report in which no single instance of an immediate postoperative complication, such as pneumothorax, hemothorax, or injury to great vessels, was seen in either group of patients undergoing successful CICVAD placement by the CV cutdown approach alone or successful CICVAD placement by subsequent ipsilateral EJV cutdown approach after an unsuccessful CV cutdown approach. The lack of such complications with venous cutdown approaches does add further support to the utilization of venous cutdown approaches for CICVAD placement in cancerpatients, however, the current report was not designed to specifically address and compare the risk of immediate postoperative complications between venous cutdown approaches and the subclavian vein percutaneous approach.It is the author's opinion that several general statements can be made with regards to CICVAD placement by way of the CV and EJV cutdown approaches in cancerpatients. First, utilization of a venous cutdown approach (whether it be by way of the CV or the EJV), as compared to the subclavian vein percutaneous approach, appears to give a uniformly high success of catheter placement and appears to give considerable perioperative safety to CICVAD placement in cancerpatients. Second, the EJV cutdown approach itself appears to be a highly successful and safe alternative route for CICVAD placement in cancerpatients when the CV cutdown approach is not technically feasible. Third, the EJV cutdown approach may be considered as a potentially useful primary route for successful CICVAD placement in cancerpatients in place of consideration of the CV cutdown approach or in place of the subclavian vein percutaneous approach. In the future, it is this author's hope that such information may encourage others to give consideration to and to broaden their utilization of venous cutdown approaches to CICVAD placement in cancerpatients. However, randomized controlled trials comparing various methods of venous access device placement are needed to answer some of the unresolved issues.
Authors: B Damascelli; G Patelli; L F Frigerio; R Lanocita; F Garbagnati; A Marchianò; C Spreafico; G Di Tolla; L Monfardini; G Porcelli Journal: AJR Am J Roentgenol Date: 1997-05 Impact factor: 3.959