Literature DB >> 15073478

Comparison of impedance cardiography to direct Fick and thermodilution cardiac output determination in pulmonary arterial hypertension.

Gordon L Yung1, Peter F Fedullo, Katie Kinninger, Wayne Johnson, Richard N Channick.   

Abstract

Cardiac output (CO) is an important diagnostic and prognostic tool for patients with ventricular dysfunction. Pulmonary hypertension patients undergo invasive right heart catheterization to determine pulmonary vascular and cardiac hemodynamics. Thermodilution (TD) and direct Fick method are the most common methods of CO determination but are costly and may be associated with complications. The latest generation of impedance cardiography (ICG) provides noninvasive estimation of CO and is now validated. The purpose of this study was to compare ICG measurement of CO to TD and direct Fick in pulmonary hypertension patients. Thirty-nine enrolled patients were analyzed: 44% were male and average age was 50.8+/-17.4 years. Results for bias and precision of cardiac index were as follows: ICG vs. Fick (-0.13 L/min/m2 and 0.46 L/min/m2), TD vs. Fick (0.10 L/min/m2 and 0.41 L/min/m2), ICG vs. TD (respectively, with a 95% level of agreement between -0.72 and 0.92 L/min/m2; CO correlation of ICG vs. Fick, TD vs. Fick, and ICG vs. TD was 0.84, 0.89, and 0.80, respectively). ICG provides an accurate, useful, and cost-effective method for determining CO in pulmonary hypertension patients, and is a potential tool for following responses to therapeutic interventions.

Entities:  

Mesh:

Year:  2004        PMID: 15073478     DOI: 10.1111/j.1527-5299.2004.03406.x

Source DB:  PubMed          Journal:  Congest Heart Fail        ISSN: 1527-5299


  9 in total

1.  Measurement of the distribution of ventilation-perfusion ratios in the human lung with proton MRI: comparison with the multiple inert-gas elimination technique.

Authors:  Rui Carlos Sá; A Cortney Henderson; Tatum Simonson; Tatsuya J Arai; Harrieth Wagner; Rebecca J Theilmann; Peter D Wagner; G Kim Prisk; Susan R Hopkins
Journal:  J Appl Physiol (1985)       Date:  2017-03-09

2.  Thermodilution vs Estimated Fick Cardiac Output Measurement in Clinical Practice: An Analysis of Mortality From the Veterans Affairs Clinical Assessment, Reporting, and Tracking (VA CART) Program and Vanderbilt University.

Authors:  Alexander R Opotowsky; Edward Hess; Bradley A Maron; Evan L Brittain; Anna E Barón; Thomas M Maddox; Laith I Alshawabkeh; Bradley M Wertheim; Meng Xu; Tufik R Assad; Jonathan D Rich; Gaurav Choudhary; Ryan J Tedford
Journal:  JAMA Cardiol       Date:  2017-10-01       Impact factor: 14.676

3.  Value of impedance cardiography in patients studied for pulmonary hypertension.

Authors:  Adriano R Tonelli; Hassan Alnuaimat; Ning Li; Robin Carrie; Kamal K Mubarak
Journal:  Lung       Date:  2011-05-24       Impact factor: 2.584

4.  Mixed Venous Oxygen Saturation Is a Better Prognosticator Than Cardiac Index in Pulmonary Arterial Hypertension.

Authors:  Ghaleb Khirfan; Allaa Almoushref; Tawfeq Naal; Batool Abuhalimeh; Raed A Dweik; Gustavo A Heresi; Adriano R Tonelli
Journal:  Chest       Date:  2020-07-03       Impact factor: 9.410

5.  Rapid intravenous infusion of 20 ml/kg saline does not impair resting pulmonary gas exchange in the healthy human lung.

Authors:  G Kim Prisk; I Mark Olfert; Tatsuya J Arai; Peter D Wagner; Susan R Hopkins
Journal:  J Appl Physiol (1985)       Date:  2009-11-12

Review 6.  Pulmonary Vascular Disease: Hemodynamic Assessment and Treatment Selection-Focus on Group II Pulmonary Hypertension.

Authors:  Bhavadharini Ramu; Brian A Houston; Ryan J Tedford
Journal:  Curr Heart Fail Rep       Date:  2018-04

Review 7.  Measuring impedance in congestive heart failure: current options and clinical applications.

Authors:  W H Wilson Tang; Wilson Tong
Journal:  Am Heart J       Date:  2008-12-16       Impact factor: 4.749

8.  Design and Implementation of a Portable Impedance Cardiography System for Noninvasive Stroke Volume Monitoring.

Authors:  Hassan Yazdanian; Amin Mahnam; Mehdi Edrisi; Morteza Abdar Esfahani
Journal:  J Med Signals Sens       Date:  2016 Jan-Mar

9.  Ventilation-perfusion heterogeneity measured by the multiple inert gas elimination technique is minimally affected by intermittent breathing of 100% O2.

Authors:  Ann R Elliott; Abhilash S Kizhakke Puliyakote; Vincent Tedjasaputra; Beni Pazár; Harrieth Wagner; Rui C Sá; Jeremy E Orr; G Kim Prisk; Peter D Wagner; Susan R Hopkins
Journal:  Physiol Rep       Date:  2020-07
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.