INTRODUCTION: The aim of this prospective randomized study was to compare the routine use of electroanatomic imaging (CARTO) with that of conventional fluoroscopically guided activation mapping (conventional) in an unselected population referred for catheter ablation. We sought to compare the two approaches with respect to procedure outcome and duration, radiation exposure, and cost. METHODS AND RESULTS:All patients undergoing catheter ablation (with the exception of complete AV nodal ablation) were prospectively randomized to either a CARTO or conventional procedure for mapping and ablation. One hundred two patients were randomized. Acute procedural success was similar with either strategy (CARTO vs conventional 43/47 vs 51/55, P > 0.5), as was procedure duration (144 [58] vs 125 [48] min, P = 0.07 (mean [SD]). CARTO was associated with a substantial reduction in fluoroscopy time (9.3 [7.6] vs 28.8 [19.5] min, P < 0.001) and radiation dose (6.2 [6.1] vs 20.8 [32.7] Gray, P = 0.003). CARTO cases used fewer catheters (2.5 [0.7] vs 4.4 [1.1], P < 0.001), but catheter costs were higher (13.8 vs 9.3 units, P < 0.001, where one unit is equivalent to the cost of a nonsteerable quadripolar catheter). CONCLUSION: For all catheter ablation procedures, even when a center's "learning curve" for CARTO is included, procedure duration and outcome are similar for CARTO and conventional procedures. CARTO is associated with drastically reduced fluoroscopy time and radiation dose. Although fewer catheters are used with CARTO, catheter costs remain higher.
RCT Entities:
INTRODUCTION: The aim of this prospective randomized study was to compare the routine use of electroanatomic imaging (CARTO) with that of conventional fluoroscopically guided activation mapping (conventional) in an unselected population referred for catheter ablation. We sought to compare the two approaches with respect to procedure outcome and duration, radiation exposure, and cost. METHODS AND RESULTS: All patients undergoing catheter ablation (with the exception of complete AV nodal ablation) were prospectively randomized to either a CARTO or conventional procedure for mapping and ablation. One hundred two patients were randomized. Acute procedural success was similar with either strategy (CARTO vs conventional 43/47 vs 51/55, P > 0.5), as was procedure duration (144 [58] vs 125 [48] min, P = 0.07 (mean [SD]). CARTO was associated with a substantial reduction in fluoroscopy time (9.3 [7.6] vs 28.8 [19.5] min, P < 0.001) and radiation dose (6.2 [6.1] vs 20.8 [32.7] Gray, P = 0.003). CARTO cases used fewer catheters (2.5 [0.7] vs 4.4 [1.1], P < 0.001), but catheter costs were higher (13.8 vs 9.3 units, P < 0.001, where one unit is equivalent to the cost of a nonsteerable quadripolar catheter). CONCLUSION: For all catheter ablation procedures, even when a center's "learning curve" for CARTO is included, procedure duration and outcome are similar for CARTO and conventional procedures. CARTO is associated with drastically reduced fluoroscopy time and radiation dose. Although fewer catheters are used with CARTO, catheter costs remain higher.
Authors: Edmond M Cronin; Frank M Bogun; Philippe Maury; Petr Peichl; Minglong Chen; Narayanan Namboodiri; Luis Aguinaga; Luiz Roberto Leite; Sana M Al-Khatib; Elad Anter; Antonio Berruezo; David J Callans; Mina K Chung; Phillip Cuculich; Andre d'Avila; Barbara J Deal; Paolo Della Bella; Thomas Deneke; Timm-Michael Dickfeld; Claudio Hadid; Haris M Haqqani; G Neal Kay; Rakesh Latchamsetty; Francis Marchlinski; John M Miller; Akihiko Nogami; Akash R Patel; Rajeev Kumar Pathak; Luis C Saenz Morales; Pasquale Santangeli; John L Sapp; Andrea Sarkozy; Kyoko Soejima; William G Stevenson; Usha B Tedrow; Wendy S Tzou; Niraj Varma; Katja Zeppenfeld Journal: J Interv Card Electrophysiol Date: 2020-10 Impact factor: 1.900
Authors: Nikola Pavlović; Tobias Reichlin; Michael Kühne; Sven Knecht; Stefan Osswald; Christian Sticherling Journal: J Interv Card Electrophysiol Date: 2014-11-15 Impact factor: 1.900
Authors: David J Sahn; Douglas N Stephens; Jonathan M Cannata; K Shung; Omer Oralkan; Amin Nikoozadeh; B T Pierre Khuri-Yakub; Hien Nguyen; Peter Chen; Aaron M Dentinger; Douglas Wildes; Kai E Thomenius; Aman Mahajan; Kalyanam Shivkumar; Matthew O'Donnell Journal: Conf Proc IEEE Eng Med Biol Soc Date: 2009
Authors: D N Stephens; J Cannata; Ruibin Liu; Jian Zhong Zhao; K K Shung; Hien Nguyen; R Chia; A Dentinger; D Wildes; K E Thomenius; A Mahajan; K Shivkumar; Kang Kim; M O'Donnell; A Nikoozadeh; O Oralkan; P T Khuri-Yakub; D J Sahn Journal: IEEE Trans Ultrason Ferroelectr Freq Control Date: 2008-07 Impact factor: 2.725