Literature DB >> 15028126

Surgical robotics: a review and neurosurgical prototype development.

Deon F Louw1, Tim Fielding, Paul B McBeth, Dennis Gregoris, Perry Newhook, Garnette R Sutherland.   

Abstract

PURPOSE: The purpose of this article is to update the neurosurgical community on the expanding field of surgical robotics and to present the design of a novel neurosurgical prototype. It is intended to mimic standard technique and deploy conventional microsurgical tools. The intention is to ease its integration into the "nervous system" of both the traditional operating room and surgeon. CONCEPT: To permit benefit from updated intraoperative imaging, magnetic resonance imaging-compatible materials were incorporated into the design. Advanced haptics, optics, and auditory communication with the surgical site recreate the sight, sound, and feel of neurosurgery. RATIONALE: Magnification and advanced imaging have pushed surgeons to the limit of their dexterity and stamina. Robots, in contrast, are indefatigable and have superior spatial resolution and geometric accuracy. The use of tremor filters and motion scalers permits procedures requiring superior dexterity. DISCUSSION: Breadboard testing of the prototype components has shown spatial resolution of 30 microm, greatly exceeding our expectations. Neurosurgeons will not only be able to perform current procedures with a higher margin of safety but also must speculate on techniques that have hitherto not even been contemplated. This includes coupling the robot to intelligent tools that interrogate tissue before its manipulation and the potential of molecular imaging to transform neurosurgical research into surgical exploration of the cell, not the organ.

Entities:  

Mesh:

Year:  2004        PMID: 15028126     DOI: 10.1227/01.neu.0000108638.05274.e9

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  19 in total

1.  Robotic neurosurgery: a preliminary study using an active vision-guided robotic arm for bone drilling and endoscopic manoeuvres.

Authors:  Mohamed Saufi Awang; Mohd Zaid Abdullah
Journal:  Malays J Med Sci       Date:  2011-04

2.  Design of Revolute Joints for In-Mold Assembly Using Insert Molding.

Authors:  Arvind Ananthanarayanan; Leicester Ehrlich; Jaydev P Desai; Satyandra K Gupta
Journal:  J Mech Des N Y       Date:  2011-11-14       Impact factor: 3.251

3.  Evaluating tactile feedback in robotic surgery for potential clinical application using an animal model.

Authors:  Christopher R Wottawa; Bradley Genovese; Bryan N Nowroozi; Steven D Hart; James W Bisley; Warren S Grundfest; Erik P Dutson
Journal:  Surg Endosc       Date:  2015-10-30       Impact factor: 4.584

Review 4.  Current state-of-the-art and future perspectives of robotic technology in neurosurgery.

Authors:  Tobias A Mattei; Abraham Hafiz Rodriguez; Deepak Sambhara; Ehud Mendel
Journal:  Neurosurg Rev       Date:  2014-04-13       Impact factor: 3.042

5.  Experimental new automatic tools for robotic stereotactic neurosurgery: towards "no hands" procedure of leads implantation into a brain target.

Authors:  P Mazzone; P Arena; L Cantelli; G Spampinato; S Sposato; S Cozzolino; P Demarinis; G Muscato
Journal:  J Neural Transm (Vienna)       Date:  2016-05-19       Impact factor: 3.575

6.  Toward the Development of a Flexible Mesoscale MRI-compatible Neurosurgical Continuum Robot.

Authors:  Yeongjin Kim; Shing Shin Cheng; Mahamadou Diakite; Rao P Gullapalli; J Marc Simard; Jaydev P Desai
Journal:  IEEE Trans Robot       Date:  2017-07-27       Impact factor: 5.567

7.  "MRI Stealth" robot for prostate interventions.

Authors:  Dan Stoianovici; Danny Song; Doru Petrisor; Daniel Ursu; Dumitru Mazilu; Michael Muntener; Michael Mutener; Michael Schar; Alexandru Patriciu
Journal:  Minim Invasive Ther Allied Technol       Date:  2007       Impact factor: 2.442

8.  Origins of intraoperative MRI.

Authors:  John M K Mislow; Alexandra J Golby; Peter M Black
Journal:  Magn Reson Imaging Clin N Am       Date:  2010-02       Impact factor: 2.266

9.  New Actuation Mechanism for Actively Cooled SMA Springs in a Neurosurgical Robot.

Authors:  Shing Shin Cheng; Yeongjin Kim; Jaydev P Desai
Journal:  IEEE Trans Robot       Date:  2017-03-29       Impact factor: 5.567

10.  Modeling and characterization of shape memory alloy springs with water cooling strategy in a neurosurgical robot.

Authors:  Shing Shin Cheng; Yeongjin Kim; Jaydev P Desai
Journal:  J Intell Mater Syst Struct       Date:  2017-01-24       Impact factor: 2.569

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.