Literature DB >> 15017019

Measurement of carotid plaque volume by 3-dimensional ultrasound.

Anthony Landry1, J David Spence, Aaron Fenster.   

Abstract

BACKGROUND AND
PURPOSE: Measurement of carotid plaque volume and its progression are important tools for research and patient management. In this study, we investigate the observer variability in the measurement of plaque volume as determined by 3-dimensional (3D) ultrasound (US). We also investigate the effect of interslice distances (ISD) and repeated 3D US scans on measurement variability. Materials and Methods Forty 3D US patient images of plaques (range, 37.43 to 604.1 mm3) were measured by manual planimetry. We applied ANOVA to determine plaque volume measurement variability and reliability. Plaque volumes were measured with 9 ISDs to determine the effect of ISD on measurement variability. Additional plaque volumes were also measured from multiple 3D US scans to investigate repeated scan acquisition variability. Results Intraobserver and interobserver measurement reliabilities were 94% and 93.2%, respectively. Plaque volume measurement variability decreased with increasing plaque volume (range, 27.1% to 2.2%). Measurement precision was constant for ISDs between 1.0 and 3.0 mm, whereas plaque volume measurement variability increased with ISD. Repeated 3D US scan measurements were not different from single-scan measurements (P=0.867). Conclusions The coefficient of variation in the measurement of plaque volume decreased with plaque size. The volumetric change that must be observed to establish with 95% confidence that a plaque has undergone change is approximately 20% to 35% for plaques <100 mm3 and approximately 10% to 20% for plaques >100 mm3. Measurement precision was unchanged for ISDs <3.0 mm, whereas measurement variability increased with ISD. Repeated 3D US scans did not affect plaque volume measurement variability.

Entities:  

Mesh:

Year:  2004        PMID: 15017019     DOI: 10.1161/01.STR.0000121161.61324.ab

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  21 in total

Review 1.  The role of carotid intimal thickness and plaque imaging in risk stratification for coronary heart disease.

Authors:  Smita I Negi; Vijay Nambi
Journal:  Curr Atheroscler Rep       Date:  2012-04       Impact factor: 5.113

Review 2.  Vascular wall imaging of vulnerable atherosclerotic carotid plaques: current state of the art and potential future of endovascular optical coherence tomography.

Authors:  B A Standish; J Spears; T R Marotta; W Montanera; V X D Yang
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-08       Impact factor: 3.825

3.  Conformal mapping of carotid vessel wall and plaque thickness measured from 3D ultrasound images.

Authors:  Gary P T Choi; Yimin Chen; Lok Ming Lui; Bernard Chiu
Journal:  Med Biol Eng Comput       Date:  2017-06-07       Impact factor: 2.602

4.  Three-dimensional ultrasound scanning.

Authors:  Aaron Fenster; Grace Parraga; Jeff Bax
Journal:  Interface Focus       Date:  2011-06-01       Impact factor: 3.906

Review 5.  Secondary Stroke Prevention: Improving Diagnosis and Management with Newer Technologies.

Authors:  Yahia Z Imam; Atlantic D'Souza; Rayaz A Malik; Ashfaq Shuaib
Journal:  Transl Stroke Res       Date:  2016-09-02       Impact factor: 6.829

6.  3D quantitative evaluation of atherosclerotic plaque based on rotational angiography.

Authors:  A Chien; J Sayre; B Dong; J Ye; F Viñuela
Journal:  AJNR Am J Neuroradiol       Date:  2011-05-19       Impact factor: 3.825

7.  Three-dimensional ultrasound measurements of carotid vessel wall and plaque thickness and their relationship with pulmonary abnormalities in ex-smokers without airflow limitation.

Authors:  Jieyu Cheng; Damien Pike; Tommy W S Chow; Miranda Kirby; Grace Parraga; Bernard Chiu
Journal:  Int J Cardiovasc Imaging       Date:  2016-06-24       Impact factor: 2.357

8.  Clinical & radiological evaluation of atherosclerotic changes in carotid & coronary arteries in asymptomatic & clinically symptomatic individuals as a tool for pre-symptomatic diagnosis of cardiovascular disease.

Authors:  Venkatraman Bhat; T N Prasad; S Ananthalakshmi; G A Karthik; George Cherian; Yaligar Dayananda
Journal:  Indian J Med Res       Date:  2016-02       Impact factor: 2.375

Review 9.  MRI of carotid atherosclerosis: clinical implications and future directions.

Authors:  Hunter R Underhill; Thomas S Hatsukami; Zahi A Fayad; Valentin Fuster; Chun Yuan
Journal:  Nat Rev Cardiol       Date:  2010-01-26       Impact factor: 32.419

10.  Direct Diagnosis is Superior to Risk Factor Prediction Tools for Management of Vessel Wall Disease.

Authors:  Afshin A Divani; Andreas R Luft; James D Flaherty; Gundu H R Rao
Journal:  Front Neurol       Date:  2012-03-13       Impact factor: 4.003

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.