Literature DB >> 28593506

Conformal mapping of carotid vessel wall and plaque thickness measured from 3D ultrasound images.

Gary P T Choi1, Yimin Chen2, Lok Ming Lui3, Bernard Chiu4.   

Abstract

Measurements of vessel-wall-plus-plaque thickness (VWT) from 3D carotid ultrasound have been shown to be sensitive to the effect of pharmaceutical interventions. Since the geometry of carotid arteries is highly subject-specific, quantitative comparison of the distributions of point-wise VWT measured for different patients or for the same patients at different ultrasound scanning sessions requires the development of a mapping strategy to adjust for the geometric variability of different carotid surface models. In this paper, we present an algorithm mapping each 3D carotid surface to a 2D carotid template with an emphasis on preserving the local geometry of the carotid surface by minimizing local angular distortion. The previously described arc-length scaling (AL) approach was applied to generate an initial 2D VWT map. Using results established in the quasi-conformal theory, a new map was computed to compensate for the angular distortion incurred in AL mapping. As the 2D carotid template lies on an L-shaped non-convex domain, one-to-one correspondence of the mapping operation was not guaranteed. To address this issue, an iterative Beltrami differential chopping and smoothing procedure was developed to enforce bijectivity. Evaluations performed in the 20 carotid surface models showed that the reduction in average angular distortion made by the proposed algorithm was highly significant (P = 2.06 × 10-5). This study is the first study showing that a bijective conformal map to a non-convex domain can be obtained using the iterative Beltrami differential chopping and smoothing procedure. The improved consistency exhibited in the 2D VWT map generated by the proposed algorithm will allow for unbiased quantitative comparisons of VWT as well as local geometric and hemodynamic quantities in population studies.

Entities:  

Keywords:  2D carotid template; 2D vessel-wall-plus-plaque thickness (VWT) map; 3D ultrasound; Carotid atherosclerosis; Conformal mapping

Mesh:

Year:  2017        PMID: 28593506     DOI: 10.1007/s11517-017-1656-4

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  31 in total

Review 1.  Three-dimensional ultrasound imaging.

Authors:  A Fenster; D B Downey
Journal:  Annu Rev Biomed Eng       Date:  2000       Impact factor: 9.590

2.  Hemodynamic shear stress and its role in atherosclerosis.

Authors:  A M Malek; S L Alper; S Izumo
Journal:  JAMA       Date:  1999-12-01       Impact factor: 56.272

3.  Flattening maps for the visualization of multibranched vessels.

Authors:  Lei Zhu; Steven Haker; Allen Tannenbaum
Journal:  IEEE Trans Med Imaging       Date:  2005-02       Impact factor: 10.048

4.  Geometry of the carotid bifurcation predicts its exposure to disturbed flow.

Authors:  Sang-Wook Lee; Luca Antiga; J David Spence; David A Steinman
Journal:  Stroke       Date:  2008-06-12       Impact factor: 7.914

5.  Concise biomarker for spatial-temporal change in three-dimensional ultrasound measurement of carotid vessel wall and plaque thickness based on a graph-based random walk framework: Towards sensitive evaluation of response to therapy.

Authors:  Bernard Chiu; Weifu Chen; Jieyu Cheng
Journal:  Comput Biol Med       Date:  2016-10-19       Impact factor: 4.589

6.  Analysis of carotid lumen surface morphology using three-dimensional ultrasound imaging.

Authors:  Bernard Chiu; Vadim Beletsky; J David Spence; Grace Parraga; Aaron Fenster
Journal:  Phys Med Biol       Date:  2009-01-27       Impact factor: 3.609

7.  Embolus detection in different degrees of carotid disease.

Authors:  B M Eicke; J von Lorentz; W Paulus
Journal:  Neurol Res       Date:  1995-06       Impact factor: 2.448

8.  Mapping spatial and temporal changes in carotid atherosclerosis from three-dimensional ultrasound images.

Authors:  Micaela Egger; Bernard Chiu; J David Spence; Aaron Fenster; Grace Parraga
Journal:  Ultrasound Med Biol       Date:  2007-08-27       Impact factor: 2.998

9.  A framework for the co-registration of hemodynamic forces and atherosclerotic plaque components.

Authors:  Gador Canton; Bernard Chiu; Huijun Chen; Yimin Chen; Thomas S Hatsukami; William S Kerwin; Chun Yuan
Journal:  Physiol Meas       Date:  2013-08-14       Impact factor: 2.833

10.  Magnetic resonance imaging and three-dimensional ultrasound of carotid atherosclerosis: mapping regional differences.

Authors:  Adam Krasinski; Bernard Chiu; Aaron Fenster; Grace Parraga
Journal:  J Magn Reson Imaging       Date:  2009-04       Impact factor: 4.813

View more
  1 in total

1.  Ultrasonography of vulnerable atherosclerotic plaque in the carotid arteries: B-mode imaging.

Authors:  Andrzej Fedak; Katarzyna Ciuk; Andrzej Urbanik
Journal:  J Ultrason       Date:  2020-06-15
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.