Literature DB >> 15014409

Materials-induced variation in the torque expression of preadjusted appliances.

Christiana Gioka1, Theodore Eliades.   

Abstract

The purpose of this article is to comprehensively investigate the sources of variation in the expression of torque in preadjusted appliances. Variables related to properties of materials were systematically analyzed, including (1) the inability to fill the slot because of the size difference of archwires and bracket slot, (2) irregularities from the manufacturing process of brackets precluding proper engagement, (3) differences in the stiffness of wire alloys engaged to the bracket slot, (4) variations between actual and reported bracket torque values, and (5) ligation modes, all of which might account for increased third-order clearance or bracket-archwire "play." The effect of these variations on the expression of torque is discussed, and the net buccolingual inclinations are provided as a function of wire size and composition for common bracket slot-archwire combinations. Most reports published on this issue indicate a loss of torque control as high as 100% of the prescribed value. Furthermore, the fallacy of transferring the ideal crown inclination to the torque prescribed in the bracket is illustrated, along with the underestimation of the prescribed torque relative to the proper tooth crown. The realistically required torque is analyzed to its constituent components, involving tooth inclination, compensation for the slot-wire play, and incomplete ligation with elastomeric ligatures. Based on the evidence available, it is proposed that a high-torque prescription should be selected to account for the lack of full expression of the prescribed torque that occurs clinically.

Mesh:

Substances:

Year:  2004        PMID: 15014409     DOI: 10.1016/j.ajodo.2003.02.007

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  33 in total

1.  Effect of material variation on the biomechanical behaviour of orthodontic fixed appliances: a finite element analysis.

Authors:  Spyridon N Papageorgiou; Ludger Keilig; Istabrak Hasan; Andreas Jäger; Christoph Bourauel
Journal:  Eur J Orthod       Date:  2015-07-14       Impact factor: 3.075

2.  Evaluation of crown inclination and angulation after orthodontic treatment using digital models : Comparison to the prescription of the brackets used.

Authors:  Iury Oliveira Castro; Bruno Frazão Gribel; Ana Helena Gonçalves de Alencar; José Valladares-Neto; Carlos Estrela
Journal:  J Orofac Orthop       Date:  2018-07       Impact factor: 1.938

3.  Orthodontic Bracket Manufacturing Tolerances and Dimensional Differences between Select Self-Ligating Brackets.

Authors:  Thomas W Major; Jason P Carey; David S Nobes; Paul W Major
Journal:  J Dent Biomech       Date:  2010-06-27

4.  How orthodontic records can influence torque choice decisions?

Authors:  Dimitrios Mavreas; Enya Kuppens; Ronald Buyl; Bart Vande Vannet
Journal:  Eur J Orthod       Date:  2015-09-25       Impact factor: 3.075

5.  Active and passive self-ligation: a myth? Part 1: torque control.

Authors:  Lorenz Martin Brauchli; Markus Steineck; Andrea Wichelhaus
Journal:  Angle Orthod       Date:  2011-11-07       Impact factor: 2.079

6.  Effect of maxillary incisor labiolingual inclination and anteroposterior position on smiling profile esthetics.

Authors:  Li Cao; Ke Zhang; Ding Bai; Yan Jing; Ye Tian; Yongwen Guo
Journal:  Angle Orthod       Date:  2011-01       Impact factor: 2.079

7.  A comparison of torque expression between stainless steel, titanium molybdenum alloy, and copper nickel titanium wires in metallic self-ligating brackets.

Authors:  Amy Archambault; Thomas W Major; Jason P Carey; Giseon Heo; Hisham Badawi; Paul W Major
Journal:  Angle Orthod       Date:  2010-09       Impact factor: 2.079

8.  Comparative assessment of clinical performance of esthetic bracket materials.

Authors:  Nikolaos Gkantidis; Spiros Zinelis; Marina Karamolegkou; Theodore Eliades; Nikolaos Topouzelis
Journal:  Angle Orthod       Date:  2012-01-09       Impact factor: 2.079

9.  Three-dimensional quantification of pretorqued nickel-titanium wires in edgewise and prescription brackets.

Authors:  Nitika Mittal; Zeyang Xia; Jie Chen; Kelton T Stewart; Sean Shih-Yao Liu
Journal:  Angle Orthod       Date:  2012-10-24       Impact factor: 2.079

10.  Comparative analysis of slot dimension in lingual bracket systems.

Authors:  Anton Demling; Marc P Dittmer; Rainer Schwestka-Polly
Journal:  Head Face Med       Date:  2009-12-15       Impact factor: 2.151

View more