Optimized precision of inversion-recovery T1 measurements for constrained scan time.

Robert J Ogg1, Peter B Kingsley.   

Abstract

Optimization of inversion-recovery (IR) measurements of T1 relaxation times has focused on the efficiency of T1 estimation (precision per unit time), without explicit consideration of the total experimental time. With the modified fast IR method, the repetition time (TR) is constant and each inversion time (TI) must be less than TR. For a fixed total experimental time in the absence of signal averaging, TR and the longest TI time must decrease as more TI times are added. This article investigates the number of TI times and their values to optimize the precision of T1 measurements when time constraints preclude signal averaging and limit the largest TI that can be acquired. If the longest TI is less than approximately three times the longest T1 of interest, then precision is optimum with only four TI times. Suggestions are given for selecting the optimum TI times for 1-16-fold ranges of T1 times relative to a given maximum T1. Copyright 2004 Wiley-Liss, Inc.

Mesh:

Substances:

Year:  2004        PMID: 15004808     DOI: 10.1002/mrm.10734

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  11 in total

1.  Rapid high-resolution three-dimensional mapping of T1 and age-dependent variations in the non-human primate brain using magnetization-prepared rapid gradient-echo (MPRAGE) sequence.

Authors:  Junjie V Liu; Nicholas A Bock; Afonso C Silva
Journal:  Neuroimage       Date:  2011-03-03       Impact factor: 6.556

2.  Multidimensional correlation spectroscopic imaging of exponential decays: From theoretical principles to in vivo human applications.

Authors:  Daeun Kim; Jessica L Wisnowski; Christopher T Nguyen; Justin P Haldar
Journal:  NMR Biomed       Date:  2020-01-07       Impact factor: 4.044

Review 3.  Dynamic Contrast-Enhanced MR Imaging in Head and Neck Cancer: Techniques and Clinical Applications.

Authors:  S Gaddikeri; R S Gaddikeri; T Tailor; Y Anzai
Journal:  AJNR Am J Neuroradiol       Date:  2015-10-01       Impact factor: 3.825

4.  A robust methodology for in vivo T1 mapping.

Authors:  Joëlle K Barral; Erik Gudmundson; Nikola Stikov; Maryam Etezadi-Amoli; Petre Stoica; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2010-10       Impact factor: 4.668

5.  Biexponential longitudinal relaxation in white matter: Characterization and impact on T1 mapping with IR-FSE and MP2RAGE.

Authors:  James A Rioux; Ives R Levesque; Brian K Rutt
Journal:  Magn Reson Med       Date:  2015-07-18       Impact factor: 4.668

6.  Optimized inversion recovery sequences for quantitative T1 and magnetization transfer imaging.

Authors:  Ke Li; Zhongliang Zu; Junzhong Xu; Vaibhav A Janve; John C Gore; Mark D Does; Daniel F Gochberg
Journal:  Magn Reson Med       Date:  2010-08       Impact factor: 4.668

7.  Ultrashort echo time imaging for quantification of hepatic iron overload: Comparison of acquisition and fitting methods via simulations, phantoms, and in vivo data.

Authors:  Aaryani Tipirneni-Sajja; Ralf B Loeffler; Axel J Krafft; Andrea N Sajewski; Robert J Ogg; Jane S Hankins; Claudia M Hillenbrand
Journal:  J Magn Reson Imaging       Date:  2018-10-25       Impact factor: 4.813

8.  A noninvasive tumor oxygenation imaging strategy using magnetic resonance imaging of endogenous blood and tissue water.

Authors:  Zhongwei Zhang; Rami R Hallac; Peter Peschke; Ralph P Mason
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

9.  Dynamic contrast-enhanced magnetic resonance imaging parameters independent of baseline T10 values.

Authors:  Jun-Yu Guo; Wilburn E Reddick; Mark A Rosen; Hee Kwon Song
Journal:  Magn Reson Imaging       Date:  2009-06-25       Impact factor: 2.546

10.  Improved three-dimensional Look-Locker acquisition scheme and angle map filtering procedure for T1 estimation.

Authors:  CheukKai Hui; Emilio Esparza-Coss; Ponnada A Narayana
Journal:  NMR Biomed       Date:  2013-06-20       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.