Literature DB >> 15004786

Cerebral perfusion assessment by bolus tracking using hyperpolarized 13C.

E Johansson1, S Månsson, R Wirestam, J Svensson, J S Petersson, K Golman, F Ståhlberg.   

Abstract

Cerebral perfusion was assessed with 13C MRI in a rat model after intravenous injections of the 13C-labeled compound bis-1,1-(hydroxymethyl)-1-13C-cyclopropane-D8 in aqueous solutions hyperpolarized by dynamic nuclear polarization (DNP). Since the tracer acted as a direct signal source, several of the problems associated with techniques based on traditional dynamic susceptibility contrast (DSC) MRI contrast agents were avoided. Maps of cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) were calculated. The MTT was determined to be 2.8 +/- 0.8 sec. However, arterial partial-volume effects in the animal model prevented accurate absolute quantification of CBF and CBV. It was demonstrated that depolarization of the hyperpolarized 13C tracer via relaxation and the imaging sequence had little influence on CBF assessment when the time resolution of the imaging sequence was short compared to the MTT. However, CBV and MTT were increasingly underestimated as MTT or the depolarization rate increased if depolarization was not taken into account. With a modified bolus-tracking theory depolarization could be compensated for, assuming that the depolarization rate was known. Three separate compensation methods were investigated experimentally and by numerical simulations. Copyright 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15004786     DOI: 10.1002/mrm.20013

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  37 in total

1.  Investigating tumor perfusion and metabolism using multiple hyperpolarized (13)C compounds: HP001, pyruvate and urea.

Authors:  Cornelius von Morze; Peder E Z Larson; Simon Hu; Hikari A I Yoshihara; Robert A Bok; Andrei Goga; Jan Henrik Ardenkjaer-Larsen; Daniel B Vigneron
Journal:  Magn Reson Imaging       Date:  2011-12-12       Impact factor: 2.546

2.  A 2DRF pulse sequence for bolus tracking in hyperpolarized 13C imaging.

Authors:  Shuyu Tang; Wenwen Jiang; Hsin-Yu Chen; Robert Bok; Daniel B Vigneron; Peder E Z Larson
Journal:  Magn Reson Med       Date:  2014-08-22       Impact factor: 4.668

Review 3.  Myocardial perfusion imaging by cardiac magnetic resonance.

Authors:  Juerg Schwitter
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

Review 4.  13C imaging-a new diagnostic platform.

Authors:  Sven Månsson; Edvin Johansson; Peter Magnusson; Chun-Ming Chai; Georg Hansson; J Stefan Petersson; Freddy Ståhlberg; Klaes Golman
Journal:  Eur Radiol       Date:  2005-06-14       Impact factor: 5.315

5.  Multispectral imaging with three-dimensional rosette trajectories.

Authors:  Elizabeth K Bucholz; Jiayu Song; G Allan Johnson; Ileana Hancu
Journal:  Magn Reson Med       Date:  2008-03       Impact factor: 4.668

Review 6.  Absolute quantification of perfusion using dynamic susceptibility contrast MRI: pitfalls and possibilities.

Authors:  Linda Knutsson; Freddy Ståhlberg; Ronnie Wirestam
Journal:  MAGMA       Date:  2009-12-04       Impact factor: 2.310

7.  Imaging of blood flow using hyperpolarized [(13)C]urea in preclinical cancer models.

Authors:  Cornelius von Morze; Peder E Z Larson; Simon Hu; Kayvan Keshari; David M Wilson; Jan Henrik Ardenkjaer-Larsen; Andrei Goga; Robert Bok; John Kurhanewicz; Daniel B Vigneron
Journal:  J Magn Reson Imaging       Date:  2011-03       Impact factor: 4.813

8.  Detection of lung transplant rejection in a rat model using hyperpolarized [1-13 C] pyruvate-based metabolic imaging.

Authors:  Sarmad Siddiqui; Andreas Habertheuer; Yi Xin; Mehrdad Pourfathi; Jian-Qin Tao; Hooman Hamedani; Stephen Kadlecek; Ian Duncan; Prashanth Vallabhajosyula; Ali Naji; Shampa Chatterjee; Rahim Rizi
Journal:  NMR Biomed       Date:  2019-05-21       Impact factor: 4.044

9.  Handheld electromagnet carrier for transfer of hyperpolarized carbon-13 samples.

Authors:  Hong Shang; Timothy Skloss; Cornelius von Morze; Lucas Carvajal; Mark Van Criekinge; Eugene Milshteyn; Peder E Z Larson; Ralph E Hurd; Daniel B Vigneron
Journal:  Magn Reson Med       Date:  2015-03-11       Impact factor: 4.668

10.  High resolution (13)C MRI with hyperpolarized urea: in vivo T(2) mapping and (15)N labeling effects.

Authors:  Galen D Reed; Cornelius von Morze; Robert Bok; Bertram L Koelsch; Mark Van Criekinge; Kenneth J Smith; Peder E Z Larson; John Kurhanewicz; Daniel B Vigneron
Journal:  IEEE Trans Med Imaging       Date:  2013-10-25       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.