Literature DB >> 14999372

[Primary rotatory stability of robot-assisted and manually implanted hip endoprosthesis stems].

M Prymka1, M Vogiatzis, J Hassenpflug.   

Abstract

In our study we compared the primary rotatory stability of hip endoprostheses implanted with the help of a robot and manually implanted stems. We examined three different types of prosthesis stems: Osteolock (Stryker-Howmedica), CBC (Mathys), and Excia (Aesculap). Ten stems of each prosthesis type were implanted in identical polyurethane foam blocks: five were implanted manually and five with the help of a robot (CASPAR, URS-Ortho). After implantation, the stem was subjected to a defined rotatory stress. The torsional moment necessary to break the stem out of the foam was documented with the help of special software. The force-displacement diagrams after robot-assisted implantations were homogeneous for each type of prosthesis. After manual preparation, the diagrams were very inhomogeneous. The rotatory test also showed very consistent results for the robot-implanted stems. The range of results after manual implantation was much higher. In all types of prostheses the use of the robot system led to a higher rotatory stability compared to the manual group. The CBC stem was most stable for rotatory forces after robot-assisted implantation compared to the other two types. After manual implantation there was no difference in stability between the different stems.

Entities:  

Mesh:

Year:  2004        PMID: 14999372     DOI: 10.1007/s00113-004-0737-7

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  13 in total

1.  Computer assisted implantation of the femoral stem in THA - an experimental study.

Authors:  J Jerosch; E Peuker; C von Hasselbach; A Lahmer; T Filler; U Witzel
Journal:  Int Orthop       Date:  1999       Impact factor: 3.075

2.  [Effect of a rasp surface on cement penetration in paired cadaver femurs].

Authors:  S J Breusch; B Lehner; J T Caillouette; U Schneider; W Wenz; J Kreutzer; V Ewerbeck; M Lukoschek
Journal:  Z Orthop Ihre Grenzgeb       Date:  2000 Jan-Feb

3.  [Long-term results with cement-free total hip prostheses (Zweymuller)].

Authors:  F C Traulsen; J Hassenpflug; H J Hahne
Journal:  Z Orthop Ihre Grenzgeb       Date:  2001 May-Jun

4.  The case for porous-coated hip implants. The femoral side.

Authors:  C A Engh; A H Glassman; K E Suthers
Journal:  Clin Orthop Relat Res       Date:  1990-12       Impact factor: 4.176

Review 5.  The rationale, design characteristics, and preliminary results of a primary custom total hip prosthesis.

Authors:  S D Stulberg; B N Stulberg; R L Wixson
Journal:  Clin Orthop Relat Res       Date:  1989-12       Impact factor: 4.176

6.  [Increasing the quality of preoperative planning and intraoperative application of computer-assisted systems and surgical robots--an experimental study].

Authors:  J Jerosch; C von Hasselbach; T Filler; E Peuker; M Rahgozar; A Lahmer
Journal:  Chirurg       Date:  1998-09       Impact factor: 0.955

7.  [Computer-guided robot-assisted hip endoprosthesis].

Authors:  M Börner; A Bauer; A Lahmer
Journal:  Orthopade       Date:  1997-03       Impact factor: 1.087

8.  The anatomic basis of femoral component design.

Authors:  P C Noble; J W Alexander; L J Lindahl; D T Yew; W M Granberry; H S Tullos
Journal:  Clin Orthop Relat Res       Date:  1988-10       Impact factor: 4.176

9.  The effect of operative fit and hydroxyapatite coating on the mechanical and biological response to porous implants.

Authors:  J E Dalton; S D Cook; K A Thomas; J F Kay
Journal:  J Bone Joint Surg Am       Date:  1995-01       Impact factor: 5.284

10.  Radiographic and morphologic studies of load-bearing porous-surfaced structured implants.

Authors:  R M Pilliar; H U Cameron; R P Welsh; A G Binnington
Journal:  Clin Orthop Relat Res       Date:  1981-05       Impact factor: 4.176

View more