Literature DB >> 14977232

Comparison of spatial filter selectivity in surface myoelectric signal detection: influence of the volume conductor model.

D Farina1, L Mesin, S Martina, R Merletti.   

Abstract

Spatial filters are used for increasing selectivity in surface EMG signal detection. The study investigated the importance of the description of the volume conductor to the inference of conclusions on comparing filter selectivity from simulation analyses. A cylindrical multi-layer description of the volume conductor was used for the simulation analysis. Different anatomies were analysed with this model, and results on filter selectivity were compared. The longitudinal single (LSD), double (LDD) and normal double differential (Laplacian, NDD) filters were investigated. Largely different conclusions could be drawn when comparing filter selectivity resulting from simulations with different volume conductor models. A filter that performed best with a particular anatomy could be the poorest with another anatomy. With a bone-muscle model and superficial fibres, the ratio between peak-to-peak values of the propagating and non-propagating signal components was approximately 220% for LDD and LSD and lower than for NDD (approximately 290%). With a bone-muscle-fat-skin model, LSD performed significantly worse (150%) than both LDD and NDD, which showed similar performances (approximately 300%). Similarly, if the lateral distance of the recording was increased by 10 degrees, the signal amplitude was reduced to 2% with LSD and LDD and to 4% with NDD. With another anatomy, LSD and LDD reduced signal amplitude to 20-25%, and NDD reduced it to 4%. Similar considerations could be drawn for other selectivity indexes. Thus, modelling should be used carefully to infer conclusions on spatial selectivity and to indicate particular choices of spatial filters.

Entities:  

Mesh:

Year:  2004        PMID: 14977232     DOI: 10.1007/bf02351020

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  24 in total

1.  A convenient method to reduce crosstalk in surface EMG. Cobb Award-winning article, 2001.

Authors:  J P van Vugt; J G van Dijk
Journal:  Clin Neurophysiol       Date:  2001-04       Impact factor: 3.708

2.  A novel approach for precise simulation of the EMG signal detected by surface electrodes.

Authors:  D Farina; R Merletti
Journal:  IEEE Trans Biomed Eng       Date:  2001-06       Impact factor: 4.538

3.  Volume conduction models for surface EMG; confrontation with measurements.

Authors:  K Roeleveld; J H. Blok; D F. Stegeman; A van Oosterom
Journal:  J Electromyogr Kinesiol       Date:  1997-12       Impact factor: 2.368

4.  Surface EMG crosstalk between knee extensor muscles: experimental and model results.

Authors:  Dario Farina; Roberto Merletti; Barbara Indino; Marisa Nazzaro; Marco Pozzo
Journal:  Muscle Nerve       Date:  2002-11       Impact factor: 3.217

5.  Three-layer volume conductor model and software package for applications in surface electromyography.

Authors:  J H Blok; D F Stegeman; A van Oosterom
Journal:  Ann Biomed Eng       Date:  2002-04       Impact factor: 3.934

6.  Single motor unit analysis from spatially filtered surface electromyogram signals. Part I: spatial selectivity.

Authors:  D Farina; E Schulte; R Merletti; G Rau; C Disselhorst-Klug
Journal:  Med Biol Eng Comput       Date:  2003-05       Impact factor: 2.602

7.  Neither high-pass filtering nor mathematical differentiation of the EMG signals can considerably reduce cross-talk.

Authors:  N A Dimitrova; G V Dimitrov; O A Nikitin
Journal:  J Electromyogr Kinesiol       Date:  2002-08       Impact factor: 2.368

8.  Precise and fast calculation of the motor unit potentials detected by a point and rectangular plate electrode.

Authors:  G V Dimitrov; N A Dimitrova
Journal:  Med Eng Phys       Date:  1998-07       Impact factor: 2.242

9.  Selective recording of motor unit potentials.

Authors:  A Gydikov; A Kossev; N Trayanova; N Radicheva
Journal:  Electromyogr Clin Neurophysiol       Date:  1986 Jun-Jul

10.  Spatial filtering of noninvasive multielectrode EMG: Part I--Introduction to measuring technique and applications.

Authors:  H Reucher; G Rau; J Silny
Journal:  IEEE Trans Biomed Eng       Date:  1987-02       Impact factor: 4.538

View more
  9 in total

1.  Advances in surface electromyographic signal simulation with analytical and numerical descriptions of the volume conductor.

Authors:  D Farina; L Mesin; S Martina
Journal:  Med Biol Eng Comput       Date:  2004-07       Impact factor: 2.602

Review 2.  Methods for estimating muscle fibre conduction velocity from surface electromyographic signals.

Authors:  D Farina; R Merletti
Journal:  Med Biol Eng Comput       Date:  2004-07       Impact factor: 2.602

3.  Influence of muscle fibre shortening on estimates of conduction velocity and spectral frequencies from surface electromyographic signals.

Authors:  E Schulte; D Farina; R Merletti; G Rau; C Disselhorst-Klug
Journal:  Med Biol Eng Comput       Date:  2004-07       Impact factor: 2.602

4.  Adaptive spatial filtering of multichannel surface electromyogram signals.

Authors:  N Ostlund; J Yu; K Roeleveld; J S Karlsson
Journal:  Med Biol Eng Comput       Date:  2004-11       Impact factor: 2.602

5.  Adaptive spatio-temporal filtering of multichannel surface EMG signals.

Authors:  Nils Ostlund; Jun Yu; J Stefan Karlsson
Journal:  Med Biol Eng Comput       Date:  2006-03-07       Impact factor: 2.602

6.  A simulation study for a surface EMG sensor that detects distinguishable motor unit action potentials.

Authors:  Jin Lee; Alexander Adam; Carlo J De Luca
Journal:  J Neurosci Methods       Date:  2007-09-18       Impact factor: 2.390

7.  [Gait analysis after minimally invasive total hip arthroplasty].

Authors:  K Sander; F Layher; C Anders; A Roth; J Babisch; H-C Scholle; R W Kinne
Journal:  Orthopade       Date:  2012-05       Impact factor: 1.087

8.  Influence of inter-electrode distance, contraction type, and muscle on the relationship between the sEMG power spectrum and contraction force.

Authors:  Javier Rodriguez-Falces; Daria Neyroud; Nicolas Place
Journal:  Eur J Appl Physiol       Date:  2014-11-21       Impact factor: 3.078

9.  Peculiarities of extracellular potentials produced by deep muscles. Part 2: motor unit potentials.

Authors:  T I Arabadzhiev
Journal:  Med Biol Eng Comput       Date:  2013-02-08       Impact factor: 2.602

  9 in total