Literature DB >> 1497445

Estimating total analytical error and its sources. Techniques to improve method evaluation.

J S Krouwer1.   

Abstract

The process of method evaluation starts with identifying goals either to demonstrate the clinical validity of an assay or to identify assay error sources that require improvement. Taguchi's idea of continual quality improvement vs the notion of meeting or failing specification has been applied to clinical chemistry. In this article, I propose a model of assay performance that includes the terms random interferences and protocol-specific biases (a series of systematic errors). I explain these terms, as well as the consequences of failing to consider them. To validate an assay clinically, I recommend direct estimation of total analytical error from a method comparison. To identify assay error sources that require improvement, I recommend a multifactor protocol (in addition to a method comparison). Individual error sources are related to total analytical error with the use of an error propagation technique. Much of the proposed data analysis techniques are straightforward but not routinely practiced. I demonstrate principles with the use of a cholesterol assay.

Entities:  

Mesh:

Year:  1992        PMID: 1497445

Source DB:  PubMed          Journal:  Arch Pathol Lab Med        ISSN: 0003-9985            Impact factor:   5.534


  4 in total

1.  Continuous cardiac output measurement by un-calibrated pulse wave analysis and pulmonary artery catheter in patients with septic shock.

Authors:  Michael T Ganter; Jamal A Alhashemi; Adel M Al-Shabasy; Ursina M Schmid; Peter Schott; Sanaa A Shalabi; Ahmed M Badri; Sonja Hartnack; Christoph K Hofer
Journal:  J Clin Monit Comput       Date:  2015-02-27       Impact factor: 2.502

Review 2.  Uncertainty in measurement: a review of monte carlo simulation using microsoft excel for the calculation of uncertainties through functional relationships, including uncertainties in empirically derived constants.

Authors:  Ian Farrance; Robert Frenkel
Journal:  Clin Biochem Rev       Date:  2014-02

Review 3.  A review of standards and statistics used to describe blood glucose monitor performance.

Authors:  Jan S Krouwer; George S Cembrowski
Journal:  J Diabetes Sci Technol       Date:  2010-01-01

4.  Accuracy and precision of four main glucometers used in a Sub-Saharan African Country: a cross-sectional study.

Authors:  Simeon-Pierre Choukem; Colette Sih; Daniel Nebongo; Philomene Tientcheu; André-Pascal Kengne
Journal:  Pan Afr Med J       Date:  2019-03-14
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.