Literature DB >> 14970112

Single-wire pressure and flow velocity measurement to quantify coronary stenosis hemodynamics and effects of percutaneous interventions.

Maria Siebes1, Bart-Jan Verhoeff, Martijn Meuwissen, Robbert J de Winter, Jos A E Spaan, Jan J Piek.   

Abstract

BACKGROUND: Lack of high-fidelity simultaneous measurements of pressure and flow velocity distal to a coronary artery stenosis has hampered the study of stenosis pressure drop-velocity (DeltaP-v) relationships in patients. METHODS AND
RESULTS: A novel 0.014-inch dual-sensor (pressure and Doppler velocity) guidewire was used in 15 coronary lesions to obtain per-beat averages of pressure drop and velocity after an intracoronary bolus of adenosine. DeltaP-v relations from resting to maximal hyperemic velocity were constructed before and after stepwise executed percutaneous coronary intervention (PCI). Before PCI, half of the DeltaP-v relations revealed the presence of a compliant stenosis, which was stabilized by angioplasty. Fractional flow reserve (FFR), coronary flow reserve (CFVR), and velocity-based indices of stenosis resistance (h-SRv) and microvascular resistance (h-MRv) at maximal hyperemia were compared. Stepwise PCI significantly lowered h-SRv, with an initial marked reduction in hyperemic pressure drop followed by further gains in velocity. A concomitant significant reduction of h-MRv accounted for half of the gain in velocity after PCI. The average magnitude of absolute incremental hemodynamic changes was highest for h-SRv (56.8+/-39.2%) compared with CFVR (35.3+/-34.5%, P<0.005) or FFR (19.5+/-25.2%, P<0.0001).
CONCLUSIONS: DeltaP-v relations comprehensively visualize improvements in coronary hemodynamics after PCI. h-SRv is a powerful and sensitive descriptor of the functional gain achieved by PCI, combining information about both pressure gradient and velocity, which are oppositely affected by PCI. Simultaneous assessment of stenosis and microvascular resistance may provide a valuable tool for guidance of PCI.

Entities:  

Mesh:

Year:  2004        PMID: 14970112     DOI: 10.1161/01.CIR.0000112571.06979.B2

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  45 in total

1.  Quantification of absolute coronary flow reserve and relative fractional flow reserve in a swine animal model using angiographic image data.

Authors:  Zhang Zhang; Shigeho Takarada; Sabee Molloi
Journal:  Am J Physiol Heart Circ Physiol       Date:  2012-06-01       Impact factor: 4.733

2.  A validated predictive model of coronary fractional flow reserve.

Authors:  Yunlong Huo; Mark Svendsen; Jenny Susana Choy; Z-D Zhang; Ghassan S Kassab
Journal:  J R Soc Interface       Date:  2011-11-23       Impact factor: 4.118

Review 3.  Theoretical models for coronary vascular biomechanics: progress & challenges.

Authors:  Sarah L Waters; Jordi Alastruey; Daniel A Beard; Peter H M Bovendeerd; Peter F Davies; Girija Jayaraman; Oliver E Jensen; Jack Lee; Kim H Parker; Aleksander S Popel; Timothy W Secomb; Maria Siebes; Spencer J Sherwin; Rebecca J Shipley; Nicolas P Smith; Frans N van de Vosse
Journal:  Prog Biophys Mol Biol       Date:  2010-10-30       Impact factor: 3.667

Review 4.  Combined functional and anatomical diagnostic endpoints for assessing arteriovenous fistula dysfunction.

Authors:  Ehsan Rajabi-Jaghargh; Rupak K Banerjee
Journal:  World J Nephrol       Date:  2015-02-06

5.  Influence of visual-functional mismatch on coronary flow profiles after percutaneous coronary intervention: a propensity score-matched analysis.

Authors:  Masahiro Hoshino; Taishi Yonetsu; Tadashi Murai; Yoshihisa Kanaji; Eisuke Usui; Masahiro Hada; Rikuta Hamaya; Yoshinori Kanno; Tetsumin Lee; Tsunekazu Kakuta
Journal:  Heart Vessels       Date:  2018-04-07       Impact factor: 2.037

6.  Intra-arterial haemodynamic changes during cerebral three-dimensional rotational angiography.

Authors:  Peter Waldenberger; Andreas Chemelli; Ammar Mallouhi
Journal:  Eur Radiol       Date:  2008-09-16       Impact factor: 5.315

7.  Characteristics of the flow velocity-pressure gradient relation in the assessment of stenoses: an in vitro study.

Authors:  K M J Marques; N Westerhof
Journal:  Neth Heart J       Date:  2008-05       Impact factor: 2.380

Review 8.  Use of the TIMI frame count in the assessment of coronary artery blood flow and microvascular function over the past 15 years.

Authors:  Vijayalakshmi Kunadian; Caitlin Harrigan; Cafer Zorkun; Alexandra M Palmer; Katherine J Ogando; Leah H Biller; Erin E Lord; Scott P Williams; Michelle E Lew; Lauren N Ciaglo; Jacqueline L Buros; Susan J Marble; William J Gibson; C Michael Gibson
Journal:  J Thromb Thrombolysis       Date:  2008-04-20       Impact factor: 2.300

9.  Mechanisms of myocardium-coronary vessel interaction.

Authors:  Dotan Algranati; Ghassan S Kassab; Yoram Lanir
Journal:  Am J Physiol Heart Circ Physiol       Date:  2009-12-04       Impact factor: 4.733

10.  Assessment of coronary microcirculation in a swine animal model.

Authors:  Zhang Zhang; Shigeho Takarada; Sabee Molloi
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-05-27       Impact factor: 4.733

View more