Literature DB >> 14968381

[Midterm results and revisions of the thrust plate prosthesis (TPP)].

B A Ishaque1, S Wienbeck, H Stürz.   

Abstract

AIM: Although already in use for 20 years, the concept of the metaphyseal anchored thrust plate prosthesis has not yet gained general acceptance. Clinical and radiological follow-up examinations were carried out 5 to 8 years after implantation of a TPP. We tried to answer the question if the metaphyseal anchorage of the cement-less TPP is equal to a diaphyseal anchorage of a cement-less stem prosthesis and to define the advantages of the TPP.
METHODS: We included 170 of the patients from our clinic with an implanted TPP in this study. Furthermore we reviewed the results of 30 revision hip arthroplasties of the TPP. The clinical examination were carried out using the Harris hip score while the radiological examinations were performed on the basis of predefined criteria.
RESULTS: We found good clinical results. The preoperative Harris score of 48.7 increased to 93.7 at 24 months postoperatively. Radiolucencies were detected and were of varying relevance in dependence on their localization. The Kaplan-Meier survival analysis at 8 years was 90.5 %. The clinical results after changing the TPP were also good to excellent. The mean Harris hip score was 87.3.
CONCLUSION: Our study suggests that in spite of a slightly higher aseptic loosening rate in comparison to the cement-less stem prosthesis, the thrust plate prosthesis proved to be worthwhile. On the basis of previous experience we assume that the TPP is a good alternative implant especially for young patients.

Entities:  

Mesh:

Year:  2004        PMID: 14968381     DOI: 10.1055/s-2004-818026

Source DB:  PubMed          Journal:  Z Orthop Ihre Grenzgeb        ISSN: 0044-3220


  7 in total

1.  [The femoral neck prosthesis CUT. Three- to six-year results].

Authors:  S A Ender; A Machner; G Pap; H Grasshoff; H W Neumann
Journal:  Orthopade       Date:  2006-08       Impact factor: 1.087

2.  Clinical and radiological mid-term results of the thrust plate prosthesis.

Authors:  W Steens; R v d Daele; U Simon; C Goetze
Journal:  Int Orthop       Date:  2009-01-28       Impact factor: 3.075

3.  Early clinical results of a new conservative hip stem.

Authors:  Jaime J Morales de Cano; Christian Gordo; Jose M Illobre
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-02-27

4.  [Femoral neck prostheses].

Authors:  C Stukenborg-Colsman
Journal:  Orthopade       Date:  2007-04       Impact factor: 1.087

5.  [Total hip arthroplasty with the cementless spiron femoral neck prosthesis].

Authors:  A Lugeder; E Häring; A Müller; P Droste; P Dorste; J Zeichen
Journal:  Oper Orthop Traumatol       Date:  2013-08       Impact factor: 1.154

6.  Changes in strain patterns after implantation of a short stem with metaphyseal anchorage compared to a standard stem: an experimental study in synthetic bone.

Authors:  Jens Gronewold; Sebastian Berner; Gavin Olender; Christof Hurschler; Henning Windhagen; Gabriela von Lewinski; Thilo Floerkemeier
Journal:  Orthop Rev (Pavia)       Date:  2014-03-18

7.  Long-term Results of the Thrust Plate Prosthesis, 21-year Follow-up: A Case Report and Literature Review.

Authors:  Hany Elbardesy; Rehan Gul
Journal:  J Orthop Case Rep       Date:  2021-04
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.