Literature DB >> 1494929

Use of end-tidal PCO2 and transcutaneous PCO2 as noninvasive measurement of arterial PCO2 in extubated patients recovering from general anesthesia.

B P Kavanagh1, A N Sandler, K E Turner, V Wick, S Lawson.   

Abstract

This study was designed to assess the accuracy of end-tidal PCO2 and transcutaneous PCO2 as measurements of arterial PCO2 in extubated, spontaneously breathing patients recovering from general anesthesia. In 30 patients, measurement of arterial transcutaneous, and end-tidal PCO2 were taken simultaneously with body temperature approximately every 15 minutes over a 2-hour period. Arterial PCO2 values were corrected for body temperature. Values for PaCO2 were compared with those for PETCO2 and PsCO2 by linear regression analysis and by calculation of bias +/- precision. Thirty-six percent of the capnogram tracings obtained did not develop a plateau phase. We found poor correlation between end-tidal and arterial PCO2 regardless of the shape of the capnogram tracing, as well as poor correlation between transcutaneous and arterial PCO2. Although the measurements of bias and precision of noninvasive PCO2 monitors in this population are comparable to studies in other populations, we advise caution in relying on the routine use of PETCO2 or PsCO2 for the noninvasive assessment of respiratory depression in extubated, spontaneously breathing patients recovering from general anesthesia.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1494929     DOI: 10.1007/bf01616780

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  13 in total

1.  Negative arterial to end-tidal gradients.

Authors:  K B Shankar; H Moseley; Y Kumar
Journal:  Can J Anaesth       Date:  1991-03       Impact factor: 5.063

2.  Temperature coefficients for PCO2 and PO2 in bloods with varying acid-base status.

Authors:  N A Bergman
Journal:  J Appl Physiol       Date:  1968-02       Impact factor: 3.531

3.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

4.  End-tidal carbon dioxide in critically ill patients during changes in mechanical ventilation.

Authors:  R A Hoffman; B P Krieger; M R Kramer; S Segel; F Bizousky; H Gazeroglu; M A Sackner
Journal:  Am Rev Respir Dis       Date:  1989-11

5.  Noninvasive monitoring of carbon dioxide: a comparison of the partial pressure of transcutaneous and end-tidal carbon dioxide with the partial pressure of arterial carbon dioxide.

Authors:  C Q Phan; K K Tremper; S E Lee; S J Barker
Journal:  J Clin Monit       Date:  1987-07

6.  Transcutaneous PCO2 monitoring on adult patients in the ICU and the operating room.

Authors:  K K Tremper; W C Shoemaker; C R Shippy; L S Nolan
Journal:  Crit Care Med       Date:  1981-10       Impact factor: 7.598

7.  Value of nocturnal monitoring of transcutaneous O2 and CO2 pressures in adults with respiratory failure.

Authors:  I Brambilla; E Micallef; C Sacerdoti; S Arlati; J Rolo
Journal:  Respiration       Date:  1985       Impact factor: 3.580

8.  Relationship between transcutaneous and arterial carbon dioxide tension in adult patients anesthetized with nitrous oxide-fentanyl and nitrous oxide-enflurane.

Authors:  T D Rafferty; O Marrero; D Nardi; E N Schachter; R Mentelos; A Hastings; D Roselli
Journal:  Anesth Analg       Date:  1981-07       Impact factor: 5.108

9.  The concept of deadspace with special reference to the single breath test for carbon dioxide.

Authors:  R Fletcher; B Jonson; G Cumming; J Brew
Journal:  Br J Anaesth       Date:  1981-01       Impact factor: 9.166

10.  Difference between end-tidal and arterial PCO2 in exercise.

Authors:  N L Jones; D G Robertson; J W Kane
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1979-11
View more
  5 in total

Review 1.  Critical review of non-invasive respiratory monitoring in medical care.

Authors:  M Folke; L Cernerud; M Ekström; B Hök
Journal:  Med Biol Eng Comput       Date:  2003-07       Impact factor: 2.602

2.  Comparative provocation test of respiratory monitoring methods.

Authors:  Mia Folke; Fredrik Granstedt; Bertil Hök; Håkan Scheer
Journal:  J Clin Monit Comput       Date:  2002-02       Impact factor: 2.502

3.  A new capnograph based on an electro acoustic sensor.

Authors:  M Folke; B Hök
Journal:  Med Biol Eng Comput       Date:  2007-09-11       Impact factor: 2.602

4.  Controlled human exposure to methyl tertiary butyl ether in gasoline: symptoms, psychophysiologic and neurobehavioral responses of self-reported sensitive persons.

Authors:  N Fiedler; K Kelly-McNeil; S Mohr; P Lehrer; R E Opiekun; C Lee; T Wainman; R Hamer; C Weisel; R Edelberg; P J Lioy
Journal:  Environ Health Perspect       Date:  2000-08       Impact factor: 9.031

5.  Correlation of end-tidal carbon dioxide with arterial carbon dioxide in mechanically ventilated patients.

Authors:  Ebrahim Razi; Gholam Abbass Moosavi; Keivan Omidi; Ashkan Khakpour Saebi; Armin Razi
Journal:  Arch Trauma Res       Date:  2012-08-21
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.