Literature DB >> 2510564

End-tidal carbon dioxide in critically ill patients during changes in mechanical ventilation.

R A Hoffman1, B P Krieger, M R Kramer, S Segel, F Bizousky, H Gazeroglu, M A Sackner.   

Abstract

Values of end-tidal CO2 (PETCO2) approximate PaCO2 in spontaneous breathing normal subjects and in stable patients receiving mechanical ventilatory support (MVS). Because marked inequality of ventilation/perfusion ratios in critically ill patients might affect this correlation, we assessed changes of PETCO2 in predicting changes in PaCO2 (delta PaCO2) and changes in minute ventilation (delta Ve) in this patient population. Twenty consecutive intubated patients 38 to 89 yr of age (mean, 70 yr) with respiratory failure while receiving MVS with indwelling arterial lines were studied. Settings on the mechanical ventilator were varied for frequency and tidal volume, and after a minimum of 5 to 10 min equilibration, PaCO2 and PETCO2 were measured. Vt and Ve were recorded from the digital indicator of the pneumotachygraph within the mechanical ventilator and corrected for compression volume in the respirator circuit. A total of 116 simultaneous measurements were performed. PETCO2 correlated well with PaCO2 (r = 0.78, p less than 0.001). The 95% confidence interval for the mean difference in PaCO2-PETCO2 was 4.0 +/- 0.97 mm Hg. However, delta PETCO2 (measured from baseline) did not correlate as well with delta PaCO2 (r = 0.58, p = less than 0.001). In four patients, the trend in their PETCO2 during changes in mechanical ventilation were in the opposite direction from the trend in their PaCO2. Thus, many critically ill patients, who cannto be preidentified, have an inconstant PaCO2-PETCO2 gradient with changes of ventilation. Utilization of PETCO2 as a noninvasive monitoring substitute for trends in PaCO2 in critically ill patients may be misleading despite establishing an initial PaCO2-PETCO2 relationship.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2510564     DOI: 10.1164/ajrccm/140.5.1265

Source DB:  PubMed          Journal:  Am Rev Respir Dis        ISSN: 0003-0805


  12 in total

Review 1.  Noninvasive blood gas monitoring: a review for use in the adult critical care unit. Technology Subcommittee of the Working Group on Critical Care, Ontario Ministry of Health.

Authors: 
Journal:  CMAJ       Date:  1992-03-01       Impact factor: 8.262

2.  Noninvasive cardiac output determined with a new method based on gas exchange measurements and carbon dioxide rebreathing: a study in animals/pigs.

Authors:  A Gedeon; P Krill; J Kristensen; I Gottlieb
Journal:  J Clin Monit       Date:  1992-10

3.  Automatic control of arterial carbon dioxide tension in mechanically ventilated patients.

Authors:  Tyrone Fernando; John Cade; John Packer
Journal:  IEEE Trans Inf Technol Biomed       Date:  2002-12

4.  Weaning from ventilation after cardiopulmonary bypass: evaluation of a non-invasive technique.

Authors:  D E Withington; J G Ramsay; A T Saoud; J Bilodeau
Journal:  Can J Anaesth       Date:  1991-01       Impact factor: 5.063

5.  Non-invasive accurate measurement of arterial PCO2 in a pediatric animal model.

Authors:  Jorn Fierstra; Jeff D Winter; Matthew Machina; Jelena Lukovic; James Duffin; Andrea Kassner; Joseph A Fisher
Journal:  J Clin Monit Comput       Date:  2012-10-26       Impact factor: 2.502

6.  Use of end-tidal PCO2 and transcutaneous PCO2 as noninvasive measurement of arterial PCO2 in extubated patients recovering from general anesthesia.

Authors:  B P Kavanagh; A N Sandler; K E Turner; V Wick; S Lawson
Journal:  J Clin Monit       Date:  1992-07

7.  Use of capnography to detect hypercapnic episodes during weaning from mechanical ventilation.

Authors:  P Saura; L Blanch; U Lucangelo; R Fernández; J Mestre; A Artigas
Journal:  Intensive Care Med       Date:  1996-05       Impact factor: 17.440

8.  Stability of the arterial to end-tidal carbon dioxide difference during anaesthesia for prolonged neurosurgical procedures.

Authors:  S K Sharma; G P McGuire; C J Cruise
Journal:  Can J Anaesth       Date:  1995-06       Impact factor: 5.063

9.  Correlation of end-tidal carbon dioxide with arterial carbon dioxide in mechanically ventilated patients.

Authors:  Ebrahim Razi; Gholam Abbass Moosavi; Keivan Omidi; Ashkan Khakpour Saebi; Armin Razi
Journal:  Arch Trauma Res       Date:  2012-08-21

10.  Correlation of end tidal and arterial carbon dioxide levels in critically Ill neonates and children.

Authors:  Hiren Mehta; Rahul Kashyap; Sangita Trivedi
Journal:  Indian J Crit Care Med       Date:  2014-06
View more