Characterization of an adult mock circulation for testing cardiac support devices.

George M Pantalos1, Steven C Koenig, Kevin J Gillars, Guruprasad A Giridharan, Dan L Ewert.   

Abstract

A need exists for a mock circulation that behaves in a physiologic manner for testing cardiac devices in normal and pathologic states. To address this need, an integrated mock cardiovascular system consisting of an atrium, ventricle, and systemic and coronary vasculature was developed specifically for testing ventricular assist devices (VADs). This test configuration enables atrial or ventricular apex inflow and aortic outflow cannulation connections. The objective of this study was to assess the ability of the mock ventricle to mimic the Frank-Starling response of normal, heart failure, and cardiac recovery conditions. The pressure-volume relationship of the mock ventricle was evaluated by varying ventricular volume over a wide range via atrial (preload) and aortic (afterload) occlusions. The input impedance of the mock vasculature was calculated using aortic pressure and flow measurements and also was used to estimate resistance, compliance, and inertial mechanical properties of the circulatory system. Results demonstrated that the mock ventricle pressure-volume loops and the end diastolic and end systolic pressure-volume relationships are representative of the Starling characteristics of the natural heart for each of the test conditions. The mock vasculature can be configured to mimic the input impedance and mechanical properties of native vasculature in the normal state. Although mock circulation testing systems cannot replace in vivo models, this configuration should be well suited for developing experimental protocols, testing device feedback control algorithms, investigating flow profiles, and training surgical staff on the operational procedures of cardiovascular devices.

Entities:  

Mesh:

Year:  2004        PMID: 14763490     DOI: 10.1097/01.mat.0000104818.70726.e6

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  19 in total

1.  A new pulse duplicator with a passive fill ventricle for analysis of cardiac dynamics.

Authors:  Yoshimasa Yokoyama; Osamu Kawaguchi; Tadahiko Shinshi; Ulrich Steinseifer; Setsuo Takatani
Journal:  J Artif Organs       Date:  2010-09-28       Impact factor: 1.731

2.  Predicted hemodynamic benefits of counterpulsation therapy using a superficial surgical approach.

Authors:  Guruprasad A Giridharan; George M Pantalos; Kenneth N Litwak; Paul A Spence; Steven C Koenig
Journal:  ASAIO J       Date:  2006 Jan-Feb       Impact factor: 2.872

3.  A Physical Heart Failure Simulation System Utilizing the Total Artificial Heart and Modified Donovan Mock Circulation.

Authors:  Jessica R Crosby; Katrina J DeCook; Phat L Tran; Edward Betterton; Richard G Smith; Douglas F Larson; Zain I Khalpey; Daniel Burkhoff; Marvin J Slepian
Journal:  Artif Organs       Date:  2016-12-09       Impact factor: 3.094

4.  Performance evaluation of a pediatric viscous impeller pump for Fontan cavopulmonary assist.

Authors:  Guruprasad A Giridharan; Steven C Koenig; Jeffrey Kennington; Michael A Sobieski; Jun Chen; Steven H Frankel; Mark D Rodefeld
Journal:  J Thorac Cardiovasc Surg       Date:  2012-03-14       Impact factor: 5.209

5.  Development and evaluation of endurance test system for ventricular assist devices.

Authors:  Hirohito Sumikura; Akihiko Homma; Kentaro Ohnuma; Yoshiyuki Taenaka; Yoshiaki Takewa; Hiroshi Mukaibayashi; Kazuo Katano; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2013-02-12       Impact factor: 1.731

6.  Experimental Validation of a Cardiac Simulator for in vitro Evaluation of Prosthetic Heart Valves.

Authors:  Ovandir Bazan; Jayme Pinto Ortiz
Journal:  Braz J Cardiovasc Surg       Date:  2016-04

7.  Physiological characterization of the SynCardia total artificial heart in a mock circulation system.

Authors:  Jessica R Crosby; Katrina J DeCook; Phat L Tran; Richard G Smith; Douglas F Larson; Zain I Khalpey; Daniel Burkhoff; Marvin J Slepian
Journal:  ASAIO J       Date:  2015 May-Jun       Impact factor: 2.872

8.  Simulated Performance of the Cleveland Clinic Continuous-Flow Total Artificial Heart Using the Virtual Mock Loop.

Authors:  Takuma Miyamoto; David J Horvath; Dennis W Horvath; Jamshid H Karimov; Nicole Byram; Barry D Kuban; Kiyotaka Fukamachi
Journal:  ASAIO J       Date:  2019-08       Impact factor: 2.872

9.  Preservation of native aortic valve flow and full hemodynamic support with the TORVAD using a computational model of the cardiovascular system.

Authors:  Jeffrey R Gohean; Mitchell J George; Kay-Won Chang; Erik R Larson; Thomas D Pate; Mark Kurusz; Raul G Longoria; Richard W Smalling
Journal:  ASAIO J       Date:  2015 May-Jun       Impact factor: 2.872

10.  In vitro pulsatility analysis of axial-flow and centrifugal-flow left ventricular assist devices.

Authors:  J Ryan Stanfield; Craig H Selzman
Journal:  J Biomech Eng       Date:  2013-03-01       Impact factor: 2.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.