In vitro pulsatility analysis of axial-flow and centrifugal-flow left ventricular assist devices.

J Ryan Stanfield, Craig H Selzman.   

Abstract

Recently, continuous-flow ventricular assist devices (CF-VADs) have supplanted older, pulsatile-flow pumps, for treating patients with advanced heart failure. Despite the excellent results of the newer generation devices, the effects of long-term loss of pulsatility remain unknown. The aim of this study is to compare the ability of both axial and centrifugal continuous-flow pumps to intrinsically modify pulsatility when placed under physiologically diverse conditions. Four VADs, two axial- and two centrifugal-flow, were evaluated on a mock circulatory flow system. Each VAD was operated at a constant impeller speed over three hypothetical cardiac conditions: normo-tensive, hypertensive, and hypotensive. Pulsatility index (PI) was compared for each device under each condition. Centrifugal-flow devices had a higher PI than that of axial-flow pumps. Under normo-tension, flow PI was 0.98 ± 0.03 and 1.50 ± 0.02 for the axial and centrifugal groups, respectively (p < 0.01). Under hypertension, flow PI was 1.90 ± 0.16 and 4.21 ± 0.29 for the axial and centrifugal pumps, respectively (p = 0.01). Under hypotension, PI was 0.73 ± 0.02 and 0.78 ± 0.02 for the axial and centrifugal groups, respectively (p = 0.13). All tested CF-VADs were capable of maintaining some pulsatile-flow when connected in parallel with our mock ventricle. We conclude that centrifugal-flow devices outperform the axial pumps from the basis of PI under tested conditions.

Entities:  

Mesh:

Year:  2013        PMID: 24231821      PMCID: PMC3705790          DOI: 10.1115/1.4023525

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  22 in total

1.  HeartMate II left ventricular assist system: from concept to first clinical use.

Authors:  B P Griffith; R L Kormos; H S Borovetz; K Litwak; J F Antaki; V L Poirier; K C Butler
Journal:  Ann Thorac Surg       Date:  2001-03       Impact factor: 4.330

2.  The history of continuous-flow blood pumps.

Authors:  D B Olsen
Journal:  Artif Organs       Date:  2000-06       Impact factor: 3.094

3.  Characterization of an adult mock circulation for testing cardiac support devices.

Authors:  George M Pantalos; Steven C Koenig; Kevin J Gillars; Guruprasad A Giridharan; Dan L Ewert
Journal:  ASAIO J       Date:  2004 Jan-Feb       Impact factor: 2.872

4.  Flow characteristics of continuous-flow left ventricular assist devices in a novel open-loop system.

Authors:  J Ryan Stanfield; Craig H Selzman; Eric R Pardyjak; Stacy Bamberg
Journal:  ASAIO J       Date:  2012 Nov-Dec       Impact factor: 2.872

5.  The need for a nonpulsatile pumping system.

Authors:  Y Nosé
Journal:  Artif Organs       Date:  1988-04       Impact factor: 3.094

6.  Pulsatile versus nonpulsatile cardiopulmonary bypass. No difference in brain blood flow or metabolism at 27 degrees C.

Authors:  B J Hindman; F Dexter; K H Ryu; T Smith; J Cutkomp
Journal:  Anesthesiology       Date:  1994-05       Impact factor: 7.892

Review 7.  Healing the heart with ventricular assist device therapy: mechanisms of cardiac recovery.

Authors:  J B Young
Journal:  Ann Thorac Surg       Date:  2001-03       Impact factor: 4.330

8.  Reversal of chronic ventricular dilation in patients with end-stage cardiomyopathy by prolonged mechanical unloading.

Authors:  H R Levin; M C Oz; J M Chen; M Packer; E A Rose; D Burkhoff
Journal:  Circulation       Date:  1995-06-01       Impact factor: 29.690

9.  Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support.

Authors:  Stefan Klotz; Mario C Deng; Joerg Stypmann; Juergen Roetker; Markus J Wilhelm; Dieter Hammel; Hans H Scheld; Christof Schmid
Journal:  Ann Thorac Surg       Date:  2004-01       Impact factor: 4.330

10.  In vitro characterization of aortic retrograde and antegrade flow from pulsatile and non-pulsatile ventricular assist devices.

Authors:  Paul L DiGiorgi; David L Smith; Yoshifumi Naka; Mehmet C Oz
Journal:  J Heart Lung Transplant       Date:  2004-02       Impact factor: 10.247

View more
  3 in total

1.  A Physical Heart Failure Simulation System Utilizing the Total Artificial Heart and Modified Donovan Mock Circulation.

Authors:  Jessica R Crosby; Katrina J DeCook; Phat L Tran; Edward Betterton; Richard G Smith; Douglas F Larson; Zain I Khalpey; Daniel Burkhoff; Marvin J Slepian
Journal:  Artif Organs       Date:  2016-12-09       Impact factor: 3.094

2.  Baseline red blood cell osmotic fragility does not predict the degree of post-LVAD hemolysis.

Authors:  Jesse L Madden; Stavros G Drakos; Josef Stehlik; Stephen H McKellar; Matthew T Rondina; Andrew S Weyrich; Craig H Selzman
Journal:  ASAIO J       Date:  2014 Sep-Oct       Impact factor: 2.872

3.  Wave Intensity Analysis of Right Ventricular Function during Pulsed Operation of Rotary Left Ventricular Assist Devices.

Authors:  J Christopher Bouwmeester; Jiheum Park; John Valdovinos; Pramod Bonde
Journal:  ASAIO J       Date:  2019-07       Impact factor: 2.872

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.