Repositioning accuracy of a commercially available double-vacuum whole body immobilization system for stereotactic body radiation therapy.

Martin Fuss1, Bill J Salter, Premavathy Rassiah, D Cheek, Sean X Cavanaugh, Terence S Herman.   

Abstract

We evaluated the repositioning accuracy of a commercially available stereotactic whole body immobilization system (BodyFIX, Medical Intelligence, Schwabmuenchen, Germany) in 36 patients treated by hypofractionated stereotactic body radiation therapy. CT data were acquired for positional control of patient and tumor before each fraction of the treatment course. Those control CT datasets were compared with the original treatment planning CT simulation and analyzed with respect to positional misalignment of bony patient anatomy, and the respective position of the treated small lung or liver lesions. We assessed the stereotactic coordinates of distinct bony anatomical landmarks in the original CT and each control dataset. In addition, the target isocenter was recorded in the planning CT simulation dataset. An iterative optimization algorithm was implemented, utilizing a root mean square scoring function to determine the best-fit orientation of subsequent sets of anatomical landmark measurements relative to the original treatment planning CT data set. This allowed for the calculation of the x, y and z-components of translation of the patient's body and the target's center-of-mass for each control CT study, as well as rotation about the principal room axes in the respective CT data sets. In addition to absolute patient/target translation, the total magnitude vector of patient and target misalignment was calculated. A clinical assessment determined whether or not the assigned planning target volume safety margins would have provided the desired target coverage. To this end, each control CT study was co-registered with the original treatment planning study using immobilization system related fiducial markers, and the computed isodose calculation was superimposed. In 109 control setup CT scans available for comparison with their respective treatment planning CT simulation study (2-5 per patient, median 3), anatomical landmark analysis revealed a mean bony landmark translation of -0.4 +/- 3.9 (mean +/- SD), -0.1 +/- 1.6 and 0.3 +/- 3.6 mm in x, y and z-directions, respectively. Bony landmark setup deviations along one or more principal axis larger than 5 mm were observed in 32 control CT studies (29.4%). Body rotations about the x-, y- and z-axis were 0.9 +/- 0.7, 0.8 +/- 0.7 and 1.8 +/- 1.6 degrees, respectively. Assuming a rigid body relationship of target and bony anatomy, the mean computed absolute target translation was 2.9 +/- 3.3, 2.3 +/- 2.5 and 3.2 +/- 2.7 mm in x, y and z-directions, respectively. The median and mean magnitude vector of target isocenter displacement was computed to be 4.9 mm, and 5.7 +/- 3.7 mm. Clinical assessment of PTV/target volume coverage revealed 72 (66.1%), 23 (21.1%), and 14 (12.8%), of excellent (100% isodose coverage), good (>90% isodose coverage), and poor GTV/isodose alignment quality (less than 90% isodose coverage to some aspect of the GTV), respectively. Loss of target volume dose coverage was correlated with translations >5 mm along one or more axes (p<0.0001), rotations >3 degrees about the z-axis (p=0.0007) and body mass index >30 (p<0.0001). The analyzed BodyFIX whole body immobilization system performed favorably compared with other stereotactic body immobilization systems for which peer-reviewed repositioning data exist. While the measured variability in patient and target setup provided clinically acceptable setup accuracy in the vast majority of cases, larger setup deviations were occasional observed. Such deviations constitute a potential for partial target underdosing warranting, in our opinion, a pre-delivery positional assessment procedure (e.g., pre-treatment control CT scan).

Entities:  

Mesh:

Year:  2004        PMID: 14750894     DOI: 10.1177/153303460400300107

Source DB:  PubMed          Journal:  Technol Cancer Res Treat        ISSN: 1533-0338


  9 in total

Review 1.  Stereotactic body radiotherapy treatment of extracranial metastases.

Authors:  Joseph K Salama; John P Kirkpatrick; Fang-Fang Yin
Journal:  Nat Rev Clin Oncol       Date:  2012-09-25       Impact factor: 66.675

2.  Evaluation of kidney motion and target localization in abdominal SBRT patients.

Authors:  Marcus Sonier; William Chu; Nafisha Lalani; Darby Erler; Patrick Cheung; Renee Korol
Journal:  J Appl Clin Med Phys       Date:  2016-11-08       Impact factor: 2.102

3.  4D CT image acquisition errors in SBRT of liver identified using correlation.

Authors:  Martin Szegedi; Vikren Sarkar; Prema Rassiah-Szegedi; Brian Wang; Y Jessica Huang; Hui Zhao; Bill Salter
Journal:  J Appl Clin Med Phys       Date:  2012-01-05       Impact factor: 2.102

Review 4.  Adaptive optimization by 6 DOF robotic couch in prostate volumetric IMRT treatment: rototranslational shift and dosimetric consequences.

Authors:  Silvia Chiesa; Lorenzo Placidi; Luigi Azario; Gian Carlo Mattiucci; Francesca Greco; Andrea Damiani; Giovanna Mantini; Vincenzo Frascino; Angelo Piermattei; Vincenzo Valentini; Mario Balducci
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

5.  Integrated-boost IMRT or 3-D-CRT using FET-PET based auto-contoured target volume delineation for glioblastoma multiforme--a dosimetric comparison.

Authors:  Marc D Piroth; Michael Pinkawa; Richard Holy; Gabriele Stoffels; Cengiz Demirel; Charbel Attieh; Hans J Kaiser; Karl J Langen; Michael J Eble
Journal:  Radiat Oncol       Date:  2009-11-23       Impact factor: 3.481

6.  Stereotactic body radiotherapy for stage I lung cancer and small lung metastasis: evaluation of an immobilization system for suppression of respiratory tumor movement and preliminary results.

Authors:  Fumiya Baba; Yuta Shibamoto; Natsuo Tomita; Chisa Ikeya-Hashizume; Kyota Oda; Shiho Ayakawa; Hiroyuki Ogino; Chikao Sugie
Journal:  Radiat Oncol       Date:  2009-05-28       Impact factor: 3.481

7.  Analysis of couch position tolerance limits to detect mistakes in patient setup.

Authors:  Scott W Hadley; James M Balter; Kwok L Lam
Journal:  J Appl Clin Med Phys       Date:  2009-10-29       Impact factor: 2.102

8.  Dosimetric effects of manual cone-beam CT (CBCT) matching for spinal radiosurgery: our experience.

Authors:  Eduard Schreibmann; Tim Fox; Ian Crocker
Journal:  J Appl Clin Med Phys       Date:  2011-04-13       Impact factor: 2.243

9.  Accuracy of 3D volumetric image registration based on CT, MR and PET/CT phantom experiments.

Authors:  Guang Li; Huchen Xie; Holly Ning; Deborah Citrin; Jacek Capala; Roberto Maass-Moreno; Peter Guion; Barbara Arora; Norman Coleman; Kevin Camphausen; Robert W Miller
Journal:  J Appl Clin Med Phys       Date:  2008-07-09       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.