Use of the NeuroMate stereotactic robot in a frameless mode for movement disorder surgery.

T R K Varma1, P R Eldridge, A Forster, S Fox, N Fletcher, M Steiger, P Littlechild, P Byrne, A Sinnott, K Tyler, S Flintham.   

Abstract

BACKGROUND/AIMS: To evaluate the use of the NeuroMate stereotactic robot with a novel ultrasound registration system for movement disorder surgery (MDS).
METHODS: Using the robot in a frameless mode, 51 patients underwent MDS. Surgical planning was carried out using MRI data obtained more than 24 h before surgery.
RESULTS: 37 out of 50 targets in the subthalamic nucleus were satisfactorily identified with a single microelectrode trajectory and the final electrode positions were at a mean distance of 1.7 mm from the calculated target. There was a significant improvement in motor scores of the Unified Parkinson's Disease Rating Scale III (off medication) at 6 (43%) and 18 months (51.7%) compared to pre-operative scores (p < 0.05).
CONCLUSIONS: The frameless robot using only MRI data can be used for MDS. The temporal separation of imaging from the surgical procedure provides additional time for detailed image analysis and planning. Copyright 2003 S. Karger AG, Basel

Entities:  

Mesh:

Year:  2003        PMID: 14745222     DOI: 10.1159/000075173

Source DB:  PubMed          Journal:  Stereotact Funct Neurosurg        ISSN: 1011-6125            Impact factor:   1.875


  7 in total

1.  [Mechatronic in functional endoscopic sinus surgery. First experiences with the daVinci Telemanipulatory System].

Authors:  G Strauss; D Winkler; S Jacobs; C Trantakis; A Dietz; F Bootz; J Meixensberger; V Falk
Journal:  HNO       Date:  2005-07       Impact factor: 1.284

Review 2.  Current state-of-the-art and future perspectives of robotic technology in neurosurgery.

Authors:  Tobias A Mattei; Abraham Hafiz Rodriguez; Deepak Sambhara; Ehud Mendel
Journal:  Neurosurg Rev       Date:  2014-04-13       Impact factor: 3.042

3.  MRI Robots for Needle-Based Interventions: Systems and Technology.

Authors:  Reza Monfaredi; Kevin Cleary; Karun Sharma
Journal:  Ann Biomed Eng       Date:  2018-06-19       Impact factor: 3.934

4.  Robotic system for MRI-guided stereotactic neurosurgery.

Authors:  Gang Li; Hao Su; Gregory A Cole; Weijian Shang; Kevin Harrington; Alex Camilo; Julie G Pilitsis; Gregory S Fischer
Journal:  IEEE Trans Biomed Eng       Date:  2015-04       Impact factor: 4.538

5.  [Artificial intelligence and its applications in medicine I: introductory background to AI and robotics].

Authors:  J F Avila-Tomás; M A Mayer-Pujadas; V J Quesada-Varela
Journal:  Aten Primaria       Date:  2020-07-11       Impact factor: 1.137

6.  Techniques of Frameless Robot-Assisted Deep Brain Stimulation and Accuracy Compared with the Frame-Based Technique.

Authors:  Shanshan Mei; Kaijia Yu; Zhiwei Ren; Yongsheng Hu; Song Guo; Yongjie Li; Jianyu Li
Journal:  Brain Sci       Date:  2022-07-11

Review 7.  Neurosurgical robotics: a review of brain and spine applications.

Authors:  Chris S Karas; E Antonio Chiocca
Journal:  J Robot Surg       Date:  2007-02-27