Literature DB >> 14743528

Effect of ramped light intensity on polymerization force and conversion in a photoactivated composite.

M R Bouschlicher1, F A Rueggeberg.   

Abstract

PURPOSE: This study evaluated the effect of ramped light intensity on the polymerization shrinkage forces and degrees of conversion (DC) of a hybrid composite.
MATERIALS AND METHODS: Composite samples were bonded between two steel rods (2.50 mm diameter, 1.25 mm apart, configuration factor = 1.0) mounted in a universal testing machine using a constant displacement mode. Polymerization contraction force was recorded for 250 seconds under four light exposure conditions: group 1, STD: (40 s x 800 mW/cm2); group 2, EXP: (150 mW/cm2 logarithmic increase to 800 mW/cm2 over 15 s) + (25 s x 800 mW/cm2); group 3, 2-STEP: (10 s x 150 mW/cm2) + (30 s x 800 mW/cm2); group 4, MED: (80 s x 400 mW/cm2). Maximum curing force (N250s) and maximum force rate of the four groups were compared using one-way analysis of variance (ANOVA) (alpha = 0.05) and the Tukey test. Degrees of conversion obtained with STD, EXP, and MED cure modes were evaluated at three depths (top surface, 1 mm, and 2 mm) using Fourier transform infrared spectroscopy (FTIR).
RESULTS: Maximum rates of polymerization shrinkage force development and standard deviations (SD), in ascending order, were group 4, MED: 0.33 +/- 0.03 N/s; group 2, EXP: 0.35 +/- 0.06 N/s; group 1, STD: 0.44 +/- 0.03 N/s; and group 3, 2-STEP: 0.46 +/- 0.07 N/s. Maximum rates of polymerization shrinkage force development of group 2, EXP and group 4, MED were statistically equivalent and lower than those of group 1, STD and group 3, 2-STEP. Maximum shrinkage forces (+/- SD), in ascending order, were group 2, EXP: 20.4 +/- 2.5 N; group 4, MED: 25.8 +/- 1.0 N; group 3, 2-STEP: 27.4 +/- 5.8 N, and group 1, STD: 30.5 +/- 2.7 N. Maximum force of the EXP mode was statistically lower than MED, 2-STEP, and STD curing modes. The EXP ramp was successful in reducing the conversion rate at the top surface and at 1.0-mm depth, but it did not affect the total conversion compared to the STD 40-second cure mode. There was no difference in DC at the top surface and 1-mm depth with mode of cure. The MED cure mode resulted in a higher DC than the EXP mode at a depth of 2 mm. CLINICAL SIGNIFICANCE: Maximum shrinkage force and force rate exhibited during the first 250 seconds of polymerization were significantly lower using a ramped light intensity exposure. Ramped light intensity decreased conversion rate at the top surface and at 1.0-mm depth and did not affect the total extent of conversion compared to a standard 40-second, single-intensity cure mode. The slower conversion rate resulting from ramped light intensity helped to reduce the rate and maximum polymerization stress, but would not be expected to compromise the physical properties for the restorative material, since similar degrees of conversion were obtained.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 14743528     DOI: 10.1111/j.1708-8240.2000.tb00242.x

Source DB:  PubMed          Journal:  J Esthet Dent        ISSN: 1040-1466


  7 in total

1.  The influence of "C-factor" and light activation technique on polymerization contraction forces of resin composite.

Authors:  Sérgio Kiyoshi Ishikiriama; Thiago Majolo Valeretto; Eduardo Batista Franco; Rafael Francisco Lia Mondelli
Journal:  J Appl Oral Sci       Date:  2012 Nov-Dec       Impact factor: 2.698

2.  Influence of pulse-delay curing on sorption and solubility of a composite resin.

Authors:  Lawrence Gonzaga Lopes; Alfeu da Veiga Jardim Filho; João Batista de Souza; Denilson Rabelo; Eduardo Batista Franco; Gersinei Carlos de Freitas
Journal:  J Appl Oral Sci       Date:  2009 Jan-Feb       Impact factor: 2.698

3.  Five second photoactivation? A microhardness and marginal adaptation in vitro study in composite resin restorations.

Authors:  Carlos Alberto Kenji Shimokawa; Paula Mendes Acatauassú Carneiro; Tamile Rocha da Silva Lobo; Victor Elias Arana-Chavez; Michel Nicolau Youssef; Míriam Lacalle Turbino
Journal:  Int Dent J       Date:  2016-04-08       Impact factor: 2.607

4.  Effects of wall compliance and light-curing protocol on wall deflection of simulated cavities in bulk-fill composite restoration.

Authors:  Chang-Ha Lee; In-Bog Lee
Journal:  J Dent Sci       Date:  2021-05-10       Impact factor: 2.080

Review 5.  Composite Resin Preheating Techniques for Cementation of Indirect Restorations.

Authors:  Déborah Lousan do Nascimento Poubel; Ana Elisa Ghanem Zanon; Júlio César Franco Almeida; Liliana Vicente Melo de Lucas Rezende; Fernanda Cristina Pimentel Garcia
Journal:  Int J Biomater       Date:  2022-03-23

6.  Effect of light-curing units and activation mode on polymerization shrinkage and shrinkage stress of composite resins.

Authors:  Lawrence Gonzaga Lopes; Eduardo Batista Franco; José Carlos Pereira; Rafael Francisco Lia Mondelli
Journal:  J Appl Oral Sci       Date:  2008 Jan-Feb       Impact factor: 2.698

7.  Composite depth of cure using four polymerization techniques.

Authors:  Ericson Janolio de Camargo; Eduardo Moreschi; Wagner Baseggio; Jaime Aparecido Cury; Renata Corrêa Pascotto
Journal:  J Appl Oral Sci       Date:  2009 Sep-Oct       Impact factor: 2.698

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.