Literature DB >> 19089287

Effect of light-curing units and activation mode on polymerization shrinkage and shrinkage stress of composite resins.

Lawrence Gonzaga Lopes1, Eduardo Batista Franco, José Carlos Pereira, Rafael Francisco Lia Mondelli.   

Abstract

The aim of this study was to evaluate the polymerization shrinkage and shrinkage stress of composites polymerized with a LED and a quartz tungsten halogen (QTH) light sources. The LED was used in a conventional mode (CM) and the QTH was used in both conventional and pulse-delay modes (PD). The composite resins used were Z100, A110, SureFil and Bisfil 2B (chemical-cured). Composite deformation upon polymerization was measured by the strain gauge method. The shrinkage stress was measured by photoelastic analysis. The polymerization shrinkage data were analyzed statistically using two-way ANOVA and Tukey test (p < or = 0.05), and the stress data were analyzed by one-way ANOVA and Tukey's test (p < or = 0.05). Shrinkage and stress means of Bisfil 2B were statistically significant lower than those of Z100, A110 and SureFil. In general, the PD mode reduced the contraction and the stress values when compared to CM. LED generated the same stress as QTH in conventional mode. Regardless of the activation mode, SureFil produced lower contraction and stress values than the other light-cured resins. Conversely, Z100 and A110 produced the greatest contraction and stress values. As expected, the chemically cured resin generated lower shrinkage and stress than the light-cured resins. In conclusion, The PD mode effectively decreased contraction stress for Z100 and A110. Development of stress in light-cured resins depended on the shrinkage value.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19089287      PMCID: PMC4327278          DOI: 10.1590/s1678-77572008000100008

Source DB:  PubMed          Journal:  J Appl Oral Sci        ISSN: 1678-7757            Impact factor:   2.698


INTRODUCTION

Tooth-colored composites have been widely used as restorative materials for anterior and posterior restorations. This reaction occurs by formation of covalent bonds during monomer conversion. Complete shrinkage can be divided into pre-gel and post-gel phases. During pre-gel polymerization, the composite flows and stresses within the structure are relieved9,18,33. Consequently, post-gel polymerization results in significant stress in the surrounding tooth structure and composite/tooth interface21,26,33. Additionally, stresses arising from polymerization shrinkage may contribute to postoperative pain, microleakage and recurrent caries37. Manufacturers have recommended high light intensity to render a higher degree of monomer conversion into polymer, thus improving the mechanical properties of composite resins. Unfortunately, the degree of conversion is always proportionally associated with shrinkage and a high rate of polymerization2,9. Clinically, the effect of postgel shrinkage and contraction stress can be minimized by flow during setting by applying short pulses of energy (pulse activation) or pre-polymerization at low-intensity light followed by a final cure at high intensity (soft-start techniques)3,33, as these methods promote a longer pre-gel phase in light-cured composites. The visco-elastic properties, such as polymerization shrinkage, polymerization reaction rate and modulus of elasticity are very important in the pattern of contraction stress18,32. Thus, the different formulations of composite resins, such as amount and type of resin matrix, filler level, and quantity of initiator and inhibitor should be considered in the contraction stress development23. Despite their popularity, the use of halogen light-curing units (LCUs) to polymerize dental composites has several setbacks33. The halogen bulbs, reflector, and filter degrade over time due to high operation temperatures and heat produced, resulting in a limited effective lifetime of about 40 to 100 hours16,27. Current LCUs using blue light emitting diodes (LEDs) have shown advantages, namely lower temperature, long lifetime, no filters, resistance to shock and vibration and narrow spectral output (440-490 nm) that falls within the camphoroquinone (CQ) absorption spectrum27,33,35,38. Because its is relatively new in dentistry, the effect of LED light on polymerization shrinkage and stress is not well reported in the dental literature. The aim of the present study was to test the hypothesis that there is no statistically significant difference in post-gel shrinkage and polymerization stress produced by halogen and LED LCUs for photocuring diferent composite resins. The second aim was to test the hypothesis that there is no statistically significant difference in conventional, pulse and chemical curing modes: and the last was to test the hypothesis that four commercially composite resins are equivalent among them.

MATERIALS AND METHODS

One chemically and three light-cured composite resins with different formulations were used in this study: a hybrid composite, Z100 (3M/ESPE, St. Paul, MN, USA; shade A2, Lot 2BA); a hybrid "packable", SureFil (Dentsply, Milford, DE, USA; shade A, Lot 010423); a microfilled composite, A110 (3M/ESPE, shade A2, Lot 2BL), and Bisfil 2B chemically cured composite (Bisco Inc., Schaumburg, IL, USA universal shade, Lot 0100003796-base and 0100004129-catalyst). The composition of these materials is presented in Table 1. The chemically cured resin composite was used according to the manufacturer's instructions. A conventional LCU (QTH; Bisco Inc.) that allowed for independent command over time and power density (VIP- variable intensity polymerizer) and a first-generation LED LCU (Dabi Atlante, Ribeirão Preto, SP, Brazil; 130 mw/cm2 power density and 450-480 nm wavelength) were used. The polymerization shrinkage and stresses generated during polymerization of the composite resin were determined using a strain gauge and by photoelastic analysis, respectively21,31.
TABLE 1

Description of the composition of the tested restorative composite resins

MaterialCompositionBatch numbers
Z100Bis-GMA, TEGDMA; Zirconia, silica2BA
Filler volume: 66%
Filler weight: 84.5%
A110Bis-GMA, TEGDMA; Silica2BL
Filler volume: 40%
Filler weight: 56%
SureFilModified Bis-GMA, urethane resin; Silanized barium, borosilicate-aluminium010423
Filler volume: 65%
Filler weight: 82%
Bisfil 2BBis-GMA, BIS-EMA; Amorphous silica, (base); TEGDMA; Silica, glass frit (catalyst)Base- 0100003796;
Filler volume: -Catalyst -0100004129
Filler weight: 75%

Polymerization Shrinkage Evaluation

The curing conditions and experimental groups are listed in Table 2. A silicone circular mold (inner diameter 5 mm and height 2.0 mm) was used and a glass slide served as the base for the set-up. A foil electrical resitance strain gauge (KFG-02-120-C1-11, Kyowa, lot Y331/064A, Japan) was attached to the flat glass surface. The gauge was 2 mm long, had an electrical resistance of 120 W and gauge factor 2.00. With the strain gauge in place, the composite resin was placed in the cavity of the silicone frame. Care was taken to ensure that the silicone mould was completely filled. A glass slide was then placed on the top of the Mylar strip for five seconds and composite resin excess was removed. The leads from the strain gauge were connected to a strain-monitoring device (SC- 2043-SG, National Instruments Corp., Austin, TX, USA) that was connected to a data acquisition system (PCI – MIO – 16×E – 50, National Instruments Corp.) and initially balanced at zero. The data obtained were analyzed with LabView software (National Instruments Corp.). The composite specimes were polymerized as described in Table 1. Dimensional changes during and after light-curing was monitored at a controlled temperature (22.5 ± 1°C). During the curing process, shrinkage measurements were taken continuously at every one second. Polymerization shrinkage measurements were taken immediately after application of the light source and after 15 minutes. Five composite specimens were used for each group. Data were obtained as microstrain and were subjected to two-way ANOVA and Tukey's test at 0.05 significance level.
TABLE 2

Description of the experimental groups and polymerization modes

GroupsComposite resinsPolymerization modeTime and intensities
Group 1ZZ100Conventional mode (CM)-QTH60 seconds- 600 mW/cm2
Group 1AA110
Group 1SSureFil
Group 2ZZ100Conventional mode – LED60 seconds- 130 mW/cm2
Group 2AA110
Group 2SSureFil
Group 3ZZ100Pulse Delay Mode (PD)-QTH3 seconds-200 mW/cm2;
Group 3AA1103 min. hiatus;
Group 3SSureFil59 seconds- 600 mW/cm2
Group 4Bisfil 2BChemical-cured

Stress shrinkage evaluation

The photoelastic material used in this study was a transparent epoxy resin (Cristal 2120- Redelease, São Paulo, SP, Brazil)10. Box-shaped cavities simulating a class I preparation (5 mm long X, 3 mm wide × 2 mm deep) were prepared by placing a transparent resin into a silicone mould containing the previously determined dimensions21 (Figure 1). Dimentions of a class I cavity were selected because of the strict C-factor of 3.1. One layer of the adhesive resin Scotchbond Multi Purpose (3M/ESPE) was applied to the inner walls of the class I cavities, and light-cured for 20 s with a visible light curing unit (VIP, Bisco Inc.) using a standardized output (600 mW/cm2). This pretreatment allowed slight bonding of the light-cured resin to the photoelastic material.
FIGURE 1

Box-shaped cavities simulating a class I preparation in transparent resin

In this part of the study, the experimental design was modified as separated groups were tested according to demonstrated in Tables 4 and 5. Composite resin was bulk filled into the cavity and cured with different polymerization modes: Z100: QTH- conventional mode-CM (60 seconds- 600 mW/cm2); LED- conventional mode- CM (60 seconds - 130 mW/cm2); QTH-pulse delay mode- PD (3 seconds-200 mW/cm2; 3 min. hiatus; 59 seconds - 600 mW/cm2); and chemical resin that was a control group; A110: QTH- CM; LED-CM; QTH-PD; and chemical-cured resin; SureFil: QTH-CM; LED-CM; QTH-PD; and chemically cured resin. For evaluation of the stress behavior of the composite resins, two curing regimens were selected: QTH-CM: Z100, A110, SureFil, and chemically cured resin that was the control group; QTH-PD: Z100; A110; SureFil and chemically cured resin. The LED-CM was not adopted for evaluation of the composite resins because the results of the pilot study were comparable to those of QTH-CM. Immediately after curing, a section of photoelastic specimen (2.0 mm in thickness) was cut perpendicularly to the long axis of the cavity with a water-cooled diamond saw (Extec Co., Enfield, CT, USA) and was polished with 1200- and 2000-grit abrasive papers (3M, Ribeirão Preto, São Paulo, Brasil) under running water (Figure 2). The experiment was carried out at 23°C ± 2°C. Seven sections were obtained for each group. Isochromatic fringes were analyzed under a polarized light microscope (Carl-Zeeiss, Germany), which contained a video-camera. The images were immediately transferred to a computer and were recorded in both color and black fields. The black field was used because it generates greater definition of stress areas making the measurement of these areas possible because stress in the photoelastic resin is only seen in one evident color (Figure 3). Only isochromatics fringes were obtained since the microscopic contained two l/4-foiles between the sample and the analyzer and the polarizer, working as circular polariscope. As the stresses produced by composite resins on the cavity walls are directly proportional to the area of fringes, the total stress was determined by measurement of these areas, which was given in square millimeters (mm2). For these stress areas of evaluation, a specific software (Image-Pro lite, 4.0 version; Media Cybernetics, Bethesda, MD, USA) was used to measure the each picture fringe area by delimitation of the stress area contorniate (Figure 4). Three readings were made for each area. The data for each group were analyzed by one-way ANOVA and multiple comparisons were performed by Tukey's test at p<0.05.
TABLE 4

Experimental groups comparing the activation mode for each light-cured composite resin and mean of stress areas (mm2)

MaterialQTH-CMLED-CMQTH-PDControl- Bisfil 2B
Z1005.7±(0.58)a 6.4±(0.24)b 4.8±(0.37)c 3.2±(0.58)d
A1107.1±(0.38)a 7.3±(0.40)a 6.1±(0.67)b 3.1±(0.62)c
SureFil3.9±(0.72)a 4.2±(0.45)a 3.7±(0.63)ab 2.8±(0.79)cb

Same letters in horizontal line = no statistically significant difference; p<0.05.

TABLE 5

Experimental groups and mean of stress areas (mm2)

Photo-actvate modeZ100A110SureFilControl- Bisfil 2B
QTH-CM9.1±(0.40)a8.5±(0.71)a 7.3±(0.30)b 5.6±(1.2)c
QTH-PD8.1±(0.65)a7.8±(0.58)a 7.0±(0.39)b 4.0±(0.50)c

Same letters in horizontal line = no statistically significant difference; p<0.05.

FIGURE 2

Cross-sectioned specimens for photoelastic analysis

FIGURE 3

Stress area recorded in black field for determination the contraction stress

FIGURE 4

Image of specime in the software used to measure each picture fringe area by delimitation of the stress area

Same letters in horizontal line = no statistically significant difference; p<0.05. Same letters in horizontal line = no statistically significant difference; p<0.05.

RESULTS

Table 3 and Figure 5 show the mean linear shrinkage during the polymerization process for the different groups studied. The stress areas (mm2) obtained with the groups are shown in Tables 4 and 5. The chemically cured composite resin produced the lowest shrinkage strain and stress (p<0.05). No shrinkage was observed during the initial four-minutes of chemical reaction (Figure 5). For light-cured composites, shrinkage occurred immediately after light polymerization when cured in conventional mode (Figure 5). For Z100 composite the QTH-CM exhibited significantly higher shrinkage than LED-CM and QTH-PD mode (G1>G2>G3). For A110 resin the LED-CM demonstrated significantly lower shrinkage, while no significant differences between QTH-CM and QTH-PD modes were found. Conversely, for SureFil, high shrinkage values were produced by QTH-CM, while no significant differences were observed between LED-CM and QTH-PD modes. Regarding the stress data for Z100, it was observed that the QTH-CM demonstrated significantly higher value than LED-CM and QTH-PD modes. However, the QTH-PD mode produced significantly lower stress value than other light-activated modes (p<0.05). For A110 and SureFil, the QTH-CM and LED-CM exhibited significantly higher stress than QTH-PD mode (p<0.05). In general, the PD mode reduced the contraction and stress values when compared to CM. SureFil composite, independently of the activation mode, showed the lowest shrinkage strain and stress when compared to Z100 and A110 composites (p<0.05). In general, Z100 and A110 showed similar results with greatest contraction strain and stress.
TABLE 3

Experimental groups and mean values of strain shrinkage (n=5) after 15 minutes (μstrain)

GroupsStrain shrinkage (±SD)
G1Z (QTH-CM-Z100)-3703.06168.5a
G1A (QTH-CM-A110)-3309.83208.2ba
G1S (QTH-CM-SureFil)-2933.51169.1c
G2Z (LED-CM-Z100)-3153.59168.5 dbc
G2A (LED-CM-A110)-2499.14208.9e
G2S (LED-CM-SureFil)-2066.31124.8fe
G3Z (QTH-PD-Z100)-2779.52218.0gcde
G3A (QTH-PD-A110)-2937.49107.9 hbcdg
G3S (QTH-CM-SureFil)-2370.67230.9 ief
G4 (Chemical-cured)-670.41128.9 j

Same letters = no statistically significant difference; p<0.05.

FIGURE 5

Shrinkage strain resulting from polymerization contraction of the experimental groups

Same letters = no statistically significant difference; p<0.05.

DISCUSSION

Polymerization shrinkage is considered a major problem with resin-based materials because it creates destructive stresses when the material is bonded to cavity walls26. In order to extend the pre-gel phase of the light-cured resins, the intensity of the light and the polymerization rate should be modified to allow molecular rearrangements and decrease of the polymerization contraction stress. The strain gauge method utilized in this study for determination of polymerization shrinkage is able to record the deformation in real time31. For contraction stress evaluation, the photoelastic method was used since it is suitable to visualize the contraction stress areas10. For this part of the evaluation, an early pilot study found that even a small variation in the proportion or manipulation of the transparent resin would produce different results. Therefore, the experimental design was modified until reproducible results were obtained. The results of this study indicated that the pulse delay mode (QTH) yielded low shrinkage values and stress as compared to the other curing modes studied. Thus, the second hypothesis was rejected. This can be explained due to the low initial energy density applied followed by a final high energy light irradiation, allowing flowing of the material between two pulses. During that initial phase of polymerization, in which the newly formed polymer is still in a flexible state, the stress developed from shrinkage can be relieved by flow of the composite, reducing the stress at the tooth/resin interface17,29. The long pre-gel phase occurs in chemically cured composite resins, in which the reaction happens slowly and with a prolonged low modulus phase12,13,15. Conversely, with light-cured composite resins, there is no pre-gel phase because of its rapid polymerization upon light activation, consequently allowing less resin flow8,17. The results with chemically cured composite resin confirmed this theory (long pre-gel phase), since the strain data showed a lower rate of polymerization and a lower strain mean than light-cured composites when cured by conventional mode. In addition, Bisfil 2B produced the lowest stress areas in the photoelastic analysis. Kinomoto, et al.20 (1999) reported that the main reason for the difference in the magnitudes of the internal stresses between chemically cured and light-cured composites in their study was considered to be that the rate of polymerization of the light-cured composite is much higher than that of the chemically cured composite. The explanation is related to the polymerization of the resin matrix that produces a gelation in which the restorative material is transformed from a viscous-plastic phase with flow into a rigid-elastic phase6,22,36. The pulse delay mode uses the same rationale for reducing the stress17,29. The first hypothesis of this study was also rejected for shrinkage evaluation. The low contraction rates produced by the LED LCU are explained by its low irradiance and low heat generated. The unit used in this study is classified as a first-generation device because the output is limited and the double-bond conversion is compromised14,25,34. For A110 resin, the LED LCU produced lower shrinkage values than QTH in conventional and pulse delay modes. This result can be explained by the greater attenuation and scattering of light by the submicron filler particles than other light-cured resins, requiring more energy for adequate polymerization4,11,30. For contraction stress evaluation, the first hypothesis was confirmed since the contraction stress data showed that, in general, the QTH in conventional mode produced similar stress to LED. The explanation for these results could be due to the polymerization rate since the LED produces wavelengths with a narrow spectrum that falls within CQ absorption spectrum resulting in an immediate chemical reaction similar to the QTH in conventional mode. Therefore, despite the low power output emitted by the first-generation LED and low contraction rate produced, this LCU produces a rapid polymerization reaction that permits less resin flow, affecting the stress production. The chemical composition of composite materials is directly related to their viscoelastic properties7,24. Properties, such as elastic modulus and shrinkage strain, have an important relationship with stress development. Strain induces a proportional stress (s) according to Hooke's law, s= e. E, in which e is the relative strain and E is the Young's modulus of the restorative material. Therefore, higher stiffness leads to increased stress for a given shrinkage strain. The opposite is also true, as the amount of shrinkage strain also plays an important role in generating stress in dental composite restorations7. The increase in the filler level will contribute to a reduced shrinkage strain because the overall polymerization shrinkage depends on the amount of polymer matrix7. On the other hand, the stiffness of the composite is also increased at high filler levels24. Comparing the three light-cured composite resins, Z100 (hybrid), A110 (microfilled) and SureFil ("packable"), different properties such as, shrinkage strain and stress development, should be observed. Thus, the third hypothesis was partially accepted because the results of this study demonstrated that the Z100 and A110 composites produced the highest shrinkage strain values and stress areas and were not different to each other. However, SureFil composite showed the lowest shrinkage strain mean and stress area. Although SureFil ("packable") presents a high stiffness, it produced the lowest stress areas. Conversely, A110 (microfilled) presented reduced stiffness, however, it generated greater stress areas as compared to SureFil. Therefore, it is very important to consider the shrinkage value of composite resins and not elastic modulus alone. The composite Z100 has Bis-GMA (Bisphenol-glycidyl methacrylate) monomer diluted with TEGDMA (triethylene glycol dimethacrylate) and the content of the filler is greater (66% in volume;Table 1). The high shrinkage strain verified by Z100 may be explained by the presence of the TEGDMA molecule, which has low molecular weight, high mobility and low viscosity, producing high polymerization shrinkage5,28. The high strain data verified with A110 composite can be explained by its composition, since it presents a high content of organic matrix (Table 1). Z100 and A110 composites showed the highest means of stress areas, despite different stiffness (21 GPA1- and 7 GPA- Technical Profile-3M, respectively). These results can be related to the development of high shrinkage strain by A110 composite. Conversely, the lower stress area mean produced by SureFil is related to the low shrinkage strain generated, since this material presents high filler load (66% in volume-Table 1). Some of these findings are supported by Ernst, et al.10 (2000), who observed low stress with a low-shrinkage composite resin.

CONCLUSIONS

The chemically cured composite provided the lowest shrinkage strain and stress means. The pulse delay (QTH) mode was effective to decrease the contraction stress. The conventional mode with QTH and LED produced the higher stress means. Otherwise, Z100 and A110 produced the highest shrinkage strain and stress means. Among the light-cured composites, SureFil generated the lowest shrinkage strain and stress area means.
  38 in total

1.  Polymerization contraction stress in light-cured packable composite resins.

Authors:  H Y Chen; J Manhart; R Hickel; K H Kunzelmann
Journal:  Dent Mater       Date:  2001-05       Impact factor: 5.304

Review 2.  Light-curing units, polymerization, and clinical implications.

Authors:  C L Davidson; A J de Gee
Journal:  J Adhes Dent       Date:  2000       Impact factor: 2.359

3.  Comparison of post-gel shrinkage strains in light-polymerized composite resins.

Authors:  Murat C Cehreli; Senay Canay
Journal:  J Prosthet Dent       Date:  2002-11       Impact factor: 3.426

4.  Effect of high intensity vs. soft-start halogen irradiation on light-cured resin-based composites. Part I. Temperature rise and polymerization shrinkage.

Authors:  Norbert Hofmann; Tanja Markert; Burkard Hugo; Bernd Klaiber
Journal:  Am J Dent       Date:  2003-12       Impact factor: 1.522

5.  Contraction force rate of polymer composites is linearly correlated with irradiance.

Authors:  R L Sakaguchi; B D Wiltbank; C F Murchison
Journal:  Dent Mater       Date:  2004-05       Impact factor: 5.304

6.  Resin composite shrinkage and marginal adaptation with different pulse-delay light curing protocols.

Authors:  Ivo Krejci; Milanka Planinic; Minos Stavridakis; Serge Bouillaguet
Journal:  Eur J Oral Sci       Date:  2005-12       Impact factor: 2.612

7.  Photoelastic analysis of polymerization contraction stresses in resin composite restorations.

Authors:  Y Kinomoto; M Torii
Journal:  J Dent       Date:  1998-03       Impact factor: 4.379

8.  Polymerization shrinkage and elasticity of flowable composites and filled adhesives.

Authors:  R Labella; P Lambrechts; B Van Meerbeek; G Vanherle
Journal:  Dent Mater       Date:  1999-03       Impact factor: 5.304

9.  Investigation of polymerisation shrinkage strain, associated cuspal movement and microleakage of MOD cavities restored incrementally with resin-based composite using an LED light curing unit.

Authors:  G J P Fleming; S Khan; O Afzal; W M Palin; F J T Burke
Journal:  J Dent       Date:  2006-07-13       Impact factor: 4.379

10.  Evaluation of a second-generation LED curing light.

Authors:  Richard B T Price; Corey A Felix; Pantelis Andreou
Journal:  J Can Dent Assoc       Date:  2003-11       Impact factor: 1.316

View more
  6 in total

1.  Clinical strategies for esthetic excellence in anterior tooth restorations: understanding color and composite resin selection.

Authors:  Flavia Pardo Salata Nahsan; Rafael Francisco Lia Mondelli; Eduardo Batista Franco; Fabiana Scarparo Naufel; Julio Katuhide Ueda; Vera Lucia Schmitt; Wagner Baseggio
Journal:  J Appl Oral Sci       Date:  2012 Mar-Apr       Impact factor: 2.698

2.  Influence of pulse-delay curing on sorption and solubility of a composite resin.

Authors:  Lawrence Gonzaga Lopes; Alfeu da Veiga Jardim Filho; João Batista de Souza; Denilson Rabelo; Eduardo Batista Franco; Gersinei Carlos de Freitas
Journal:  J Appl Oral Sci       Date:  2009 Jan-Feb       Impact factor: 2.698

3.  Effect of light sources and curing mode techniques on sorption, solubility and biaxial flexural strength of a composite resin.

Authors:  Andreia Assis Carvalho; Francine do Couto Lima Moreira; Rodrigo Borges Fonseca; Carlos José Soares; Eduardo Batista Franco; João Batista de Souza; Lawrence Gonzaga Lopes
Journal:  J Appl Oral Sci       Date:  2012 Mar-Apr       Impact factor: 2.698

4.  The effect of different organic solvents on the degradation of restorative materials.

Authors:  Josué Martos; Luiz Fernando Machado Silveira; Carina Folgearini Silveira; Luis Antonio Suita de Castro; Carmen María Ferrer-Luque
Journal:  Eur J Dent       Date:  2013-07

5.  Effect of reduced exposure times on the cytotoxicity of resin luting cements cured by high-power led.

Authors:  Gulfem Ergun; Ferhan Egilmez; Sukran Yilmaz
Journal:  J Appl Oral Sci       Date:  2011 May-Jun       Impact factor: 2.698

Review 6.  Photoelasticity for Stress Concentration Analysis in Dentistry and Medicine.

Authors:  Miriam Marín-Miranda; Ana María Wintergerst; Yoshamin Abnoba Moreno-Vargas; María Lilia Adriana Juárez-López; Cesar Tavera-Ruiz
Journal:  Materials (Basel)       Date:  2022-09-30       Impact factor: 3.748

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.