The influence of "C-factor" and light activation technique on polymerization contraction forces of resin composite.

Sérgio Kiyoshi Ishikiriama1, Thiago Majolo Valeretto, Eduardo Batista Franco, Rafael Francisco Lia Mondelli.   

Abstract

OBJECTIVES: This study evaluated the influence of the cavity configuration factor ("C-Factor") and light activation technique on polymerization contraction forces of a Bis-GMA-based composite resin (Charisma, Heraeus Kulzer).
MATERIAL AND METHODS: Three different pairs of steel moving bases were connected to a universal testing machine (emic DL 500): groups A and B - 2x2 mm (CF=0.33), groups C and D - 3x2 mm (CF=0.66), groups e and F - 6x2 mm (CF=1.5). After adjustment of the height between the pair of bases so that the resin had a volume of 12 mm³ in all groups, the material was inserted and polymerized by two different methods: pulse delay (100 mW/cm² for 5 s, 40 s interval, 600 mW/cm² for 20 s) and continuous pulse (600 mW/cm² for 20 s). Each configuration was light cured with both techniques. Tensions generated during polymerization were recorded by 120 s. The values were expressed in curves (Force(N) x Time(s)) and averages compared by statistical analysis (ANOVA and Tukey's test, p<0.05).
RESULTS: For the 2x2 and 3x2 bases, with a reduced C-Factor, significant differences were found between the light curing methods. For 6x2 base, with high C-Factor, the light curing method did not influence the contraction forces of the composite resin.
CONCLUSIONS: Pulse delay technique can determine less stress on tooth/restoration interface of adhesive restorations only when a reduced C-Factor is present.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23329240      PMCID: PMC3881863          DOI: 10.1590/s1678-77572012000600003

Source DB:  PubMed          Journal:  J Appl Oral Sci        ISSN: 1678-7757            Impact factor:   2.698


  23 in total

1.  Novel approach to measure composite conversion kinetics during exposure with stepped or continuous light-curing.

Authors:  F A Rueggeberg; W F Caughman; D C Chan
Journal:  J Esthet Dent       Date:  1999

Review 2.  An alternative method to reduce polymerization shrinkage in direct posterior composite restorations.

Authors:  Simone Deliperi; David N Bardwell
Journal:  J Am Dent Assoc       Date:  2002-10       Impact factor: 3.634

3.  Contraction force rate of polymer composites is linearly correlated with irradiance.

Authors:  R L Sakaguchi; B D Wiltbank; C F Murchison
Journal:  Dent Mater       Date:  2004-05       Impact factor: 5.304

4.  Early marginal leakage and shear bond strength of adhesive restorative systems.

Authors:  C Prati; C Nucci; C L Davidson; G Montanari
Journal:  Dent Mater       Date:  1990-07       Impact factor: 5.304

5.  Shrinkage stress in light-cured composite resins: influence of material and photoactivation mode.

Authors:  Christophe Charton; Pierre Colon; Fernand Pla
Journal:  Dent Mater       Date:  2006-10-06       Impact factor: 5.304

6.  Role of additional retention on marginal adaptation and sealing of large resin composite Class II restorations.

Authors:  Sérgio Kiyoshi Ishikiriama; Rafael Francisco Lia Mondelli; Stefania Carvalho Kano; Aquira Ishikiriama; José Mondelli
Journal:  Oper Dent       Date:  2007 Nov-Dec       Impact factor: 2.440

7.  Effect of sequential versus continuous irradiation of a light-cured resin composite on shrinkage, viscosity, adhesion, and degree of polymerization.

Authors:  P Koran; R Kürschner
Journal:  Am J Dent       Date:  1998-02       Impact factor: 1.522

8.  In vitro measurement of cuspal strain and displacement in composite restored teeth.

Authors:  N Meredith; D J Setchell
Journal:  J Dent       Date:  1997 May-Jul       Impact factor: 4.379

9.  Wear resistance of packable resin composites after simulated toothbrushing test.

Authors:  Linda Wang; Fernanda Cristina Pimentel Garcia; Paulo Amarante de Araújo; Eduardo Batista Franco; Rafael Francisco Lia Mondelli
Journal:  J Esthet Restor Dent       Date:  2004       Impact factor: 2.843

10.  The influence of plasma arc vs. halogen standard or soft-start irradiation on polymerization shrinkage kinetics of polymer matrix composites.

Authors:  Norbert Hofmann; Walter Denner; Burkard Hugo; Bernd Klaiber
Journal:  J Dent       Date:  2003-08       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.