Optimal pacing for symptomatic AV block: a comparison of VDD and DDD pacing.

Max Huang1, Andrew D Krahn, Raymond Yee, George J Klein, Allan C Skanes.   

Abstract

VDD pacing provides the physiological benefits of atrioventricular synchronous pacing with the convenience of a single lead system, but is hampered by uncertainty regarding long term atrial sensing and potential development of sinus node disease. To examine the long-term reliability and complication rates of VDD pacing, we compared the outcome of 112 consecutive patients (age 70 +/- 13 years, 59% men) with symptomatic AV block who received a single pass bipolar VDD system, to 80 patients (age 63 +/- 16 years, 70% men) who received DDD pacing for the same indication. All patients were judged to have intact sinus node function based on submitted ECGs and monitoring results at the time of implant. Implant time was reduced in VDD patients compared to DDD patients (63 +/- 20 vs 97 +/- 36 minutes, P < 0.0001). Implant complications occurred in 5 (6%) DDD patients compared to 3 (3%) VDD patients (P = 0.15). The implant P wave was lower with VDD pacing compared to DDD patients (2.91 +/- 1.48 vs 4.0 +/- 1.7 mv, P < 0.0001), but remained stable during long-term follow-up in both groups. During 17.7 +/- 10.0 months of follow-up in the VDD group, only two VDD patients were reprogrammed to VVIR mode, compared to three DDD patients. Physiological atrioventricular activation was maintained in 94%-99% of beats throughout the follow-up period in the VDD group. VDD pacing is an excellent strategy for treatment of patients with symptomatic AV block. The lower cost, high reliability, and abbreviated implantation time suggest that VDD pacing is a viable alternative to DDD pacing in patients with high degree AV block and normal sinus node function.

Entities:  

Mesh:

Year:  2004        PMID: 14720150     DOI: 10.1111/j.1540-8159.2004.00380.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  5 in total

1.  [Atrial sensing with fixed and floating electrodes at identical activities].

Authors:  D Hartung; L Thiele; W M Hartung
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2009-04-18

2.  Effects of AV-delay optimization on hemodynamic parameters in patients with VDD pacemakers.

Authors:  Konstantin A Krychtiuk; Michael Nürnberg; Romana Volker; Linda Pachinger; Rudolf Jarai; Matthias K Freynhofer; Johann Wojta; Kurt Huber; Thomas W Weiss
Journal:  Wien Klin Wochenschr       Date:  2014-03-21       Impact factor: 1.704

3.  Current concepts in pacing 2010-2011: the right and wrong way to pace.

Authors:  Simon Modi; Andrew Krahn; Raymond Yee
Journal:  Curr Treat Options Cardiovasc Med       Date:  2011-10

4.  The impact of the distance between the atrial electrode and the atrial wall on atrial undersensing in patients with VDD pacemakers: long-term follow-up.

Authors:  Timucin Altin; Muharrem Guldal; Basar Candemir; Cegerhun Polat; Aydan O Ozdemir; Cansin Tulunay; Cagdas Ozdol; Omer Akyurek; Remzi Karaoguz; Cetin Erol
Journal:  Ann Noninvasive Electrocardiol       Date:  2008-10       Impact factor: 1.468

5.  Intracardiac atrial signal amplitude in congenital and acquired complete heart block.

Authors:  Mohammad Reza Samiei Nasab; Mohammad Reza Dehghani; Mehrdad Taherioun; Alireza Rostamzadeh
Journal:  Indian Pacing Electrophysiol J       Date:  2010-10-31
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.