Literature DB >> 14716646

Primary total hip arthroplasty with a flanged, cemented all-polyethylene acetabular component: evaluation at a minimum of 20 years.

Craig J Della Valle1, Kevin Kaplan, Adele Jazrawi, Shazia Ahmed, William L Jaffe.   

Abstract

One hundred twenty-three consecutive primary total hip arthroplasties in 107 patients were performed with the insertion of a cemented, all polyethylene, flanged acetabular component. At a minimum of 20 years, 66 patients had died (75 hips) and 8 patients (8 hips) were lost to follow-up evaluation, leaving 40 hips in 33 patients. At a mean of 21.1 years, 2 cups had been revised for aseptic loosening, one well-fixed cup was revised at the time of femoral component revision, and 4 additional cups had definite evidence of radiographic loosening. Survivorship analysis revealed a 77.3% survivorship for the component at 21 years, with revision or definite loosening as an endpoint (95% confidence interval, 67.8%-86.8%).

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14716646     DOI: 10.1016/j.arth.2003.08.002

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  8 in total

1.  Assessing the accuracy factors in the determination of postoperative acetabular cup orientation using hybrid 2D-3D registration.

Authors:  Guoyan Zheng
Journal:  J Digit Imaging       Date:  2009-07-21       Impact factor: 4.056

2.  Computer assisted determination of acetabular cup orientation using 2D-3D image registration.

Authors:  Guoyan Zheng; Xuan Zhang
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-02-24       Impact factor: 2.924

3.  Is the acetabular cup orientation after total hip arthroplasty on a two dimension or three dimension model accurate?

Authors:  Benjamin Craiovan; Tobias Renkawitz; Markus Weber; Joachim Grifka; Lutz Nolte; Guoyan Zheng
Journal:  Int Orthop       Date:  2014-04-16       Impact factor: 3.075

4.  Validation of a statistical shape model-based 2D/3D reconstruction method for determination of cup orientation after THA.

Authors:  G Zheng; J von Recum; L-P Nolte; P A Grützner; S D Steppacher; J Franke
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-07-27       Impact factor: 2.924

5.  The influence of a suction device on fixation of a cemented cup using RSA.

Authors:  A John Timperley; Sarah L Whitehouse; Patrick G Hourigan
Journal:  Clin Orthop Relat Res       Date:  2008-11-08       Impact factor: 4.176

6.  Basic science considerations in primary total hip replacement arthroplasty.

Authors:  Saqeb B Mirza; Douglas G Dunlop; Sukhmeet S Panesar; Syed G Naqvi; Shafat Gangoo; Saif Salih
Journal:  Open Orthop J       Date:  2010-05-11

7.  Cementless total hip arthroplasty for primary osteoarthritis in patients aged 55 years and older.

Authors:  Keijo T Mäkelä; Antti Eskelinen; Pekka Paavolainen; Pekka Pulkkinen; Ville Remes
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

8.  Results of 3,668 primary total hip replacements for primary osteoarthritis in patients under the age of 55 years.

Authors:  Keijo T Mäkelä; Antti Eskelinen; Pekka Pulkkinen; Pekka Paavolainen; Ville Remes
Journal:  Acta Orthop       Date:  2011-10       Impact factor: 3.717

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.