Literature DB >> 14713090

Feldkamp-based cone-beam reconstruction for gantry-tilted helical multislice CT.

Ilmar Hein1, Katsuyuki Taguchi, Michael D Silver, Masahiro Kazama, Issei Mori.   

Abstract

Depending on the clinical application, it is frequently necessary to tilt the gantry of an x-ray CT system with respect to the patient and couch. For single-slice fan-beam systems, tilting the gantry introduces no errors or artifacts. Most current systems, however, are helical multislice systems with up to 16 slices. The multislice helical reconstruction algorithms used to create CT images must be modified to account for tilting of the gantry. If they are not, the quality of reconstructed images will be poor with the presence of significant artifacts, such as smearing and double-imaging of anatomical structures. Current CT systems employ three primary types of reconstruction algorithms: helical fan-beam approximation, advanced single-slice rebinning, and Feldkamp-based algorithms. This paper presents a generalized helical cone-beam Feldkamp-based algorithm that is valid for both tilted and nontilted orientations of the gantry. Unlike some of the other algorithms, generalization of the Feldkamp algorithm to include gantry tilt is simple and straightforward with no significant increase in computational complexity. The effect of gantry tilt for helical Feldkamp reconstruction is to introduce a lateral shift in the isocenter of the reconstructed slice of interest, which is a function of the tilt, couch speed, and view angle. The lateral shift is easily calculated and incorporated into the helical Feldkamp backprojection algorithm. A tilt-generalized helical Feldkamp algorithm has been developed and incorporated into Aquilion 16-slice CT (Toshiba, Japan) scanners. This paper describes modifications necessary for the tilt generalization and its verification.

Entities:  

Mesh:

Year:  2003        PMID: 14713090     DOI: 10.1118/1.1625443

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Cone-beam computed tomography arthrography: an innovative modality for the evaluation of wrist ligament and cartilage injuries.

Authors:  Reeta Ramdhian-Wihlm; Jean-Marie Le Minor; Matthieu Schmittbuhl; Jeremy Jeantroux; Peter Mac Mahon; Francis Veillon; Jean-Claude Dosch; Jean-Louis Dietemann; Guillaume Bierry
Journal:  Skeletal Radiol       Date:  2011-11-08       Impact factor: 2.199

2.  Properties of the prototype 256-row (cone beam) CT scanner.

Authors:  Shinichiro Mori; Masahiro Endo; Takayuki Obata; Takanori Tsunoo; Kandatsu Susumu; Shuji Tanada
Journal:  Eur Radiol       Date:  2006-03-28       Impact factor: 5.315

3.  Temporally targeted imaging method applied to ECG-gated computed tomography: preliminary phantom and in vivo experience.

Authors:  Brian E Nett; Shuai Leng; Joseph N Zambelli; Scott B Reeder; Michael A Speidel; Guang-Hong Chen
Journal:  Acad Radiol       Date:  2008-01       Impact factor: 3.173

Review 4.  CT angiography: current technology and clinical use.

Authors:  Kanako K Kumamaru; Bernice E Hoppel; Richard T Mather; Frank J Rybicki
Journal:  Radiol Clin North Am       Date:  2010-03       Impact factor: 2.303

5.  Tensor framelet based iterative image reconstruction algorithm for low-dose multislice helical CT.

Authors:  Haewon Nam; Minghao Guo; Hengyong Yu; Keumsil Lee; Ruijiang Li; Bin Han; Lei Xing; Rena Lee; Hao Gao
Journal:  PLoS One       Date:  2019-01-11       Impact factor: 3.240

6.  A fast CT reconstruction scheme for a general multi-core PC.

Authors:  Kai Zeng; Erwei Bai; Ge Wang
Journal:  Int J Biomed Imaging       Date:  2007
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.