Effects of quantum noise and binocular summation on dose requirements in stereoradiography.

Andrew D A Maidment1, Predrag R Bakic, Michael Albert.   

Abstract

In the case of a quantum-noise limited detector, signal detection theory suggests that stereoradiographic images can be acquired with one half of the per-image dose needed for a standard radiographic projection, as information from the two stereo images can be combined. Previously, film-screen stereoradiography has been performed using the same per-image dose as in projection radiography, i.e., doubling the total dose. In this paper, the assumption of a possible decrease in dose for stereoradiography was tested by a series of contrast-detail experiments, using phantom images acquired over a range of exposures. The number of visible details, the effective reduction of the dose, and the effective decrease in the threshold signal-to-noise ratio were determined using human observers under several display and viewing conditions. These results were averaged over five observers and compared with multiple readings by a single observer and with the results of an additional observer with limited stereoscopic acuity. Experimental results show that the total dose needed to produce a stereoradiographic image pair is approximately 1.1 times the dose needed for a single projection in standard radiography, indicating that under these conditions the human visual system demonstrates almost ideal binocular summation.

Entities:  

Mesh:

Year:  2003        PMID: 14713072     DOI: 10.1118/1.1621869

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Matching methods evaluation framework for stereoscopic breast x-ray images.

Authors:  Johanna Rousson; Mathieu Naudin; Cédric Marchessoux
Journal:  J Med Imaging (Bellingham)       Date:  2015-11-18

2.  Real-time stereographic rendering and display of medical images with programmable GPUs.

Authors:  Xiao Hui Wang; Walter F Good
Journal:  Comput Med Imaging Graph       Date:  2007-12-03       Impact factor: 4.790

Review 3.  Breast cancer imaging: a perspective for the next decade.

Authors:  Andrew Karellas; Srinivasan Vedantham
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

4.  Towards optimized acquisition scheme for multiprojection correlation imaging of breast cancer.

Authors:  Amarpreet S Chawla; Robert S Saunders; Swatee Singh; Joseph Y Lo; Ehsan Samei
Journal:  Acad Radiol       Date:  2009-04       Impact factor: 3.173

5.  A mathematical model platform for optimizing a multiprojection breast imaging system.

Authors:  Amarpreet S Chawla; Ehsan Samei; Robert S Saunders; Joseph Y Lo; Jay A Baker
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.