Sensitivity encoding (SENSE) for high spatial resolution time-of-flight MR angiography of the intracranial arteries at 3.0 T.

W A Willinek1, J Gieseke, M von Falkenhausen, M Born, D Hadizadeh, C Manka, H J Textor, H H Schild, C K Kuhl.   

Abstract

PURPOSE: 1) To evaluate feasibility of sensitivity encoding (SENSE) for high spatial resolution intracranial 3D time-of-flight (TOF) MR angiography at 3.0 T using a 1024 imaging matrix and 2) to compare image quality and diagnostic yield with 3.0 T TOF MRA without SENSE.
METHODS: In a prospective study TOF MR angiography of the circle of Willis was performed with SENSE in 24 patients on a clinical whole body 3.0 T MR system (Intera, Philips Medical Systems, NL). In the SENSE protocol (S-MRA), a SENSE factor of 2.5 was used to shorten acquisition time and to increase the anatomic coverage (5:12 min.; 150 slices). A matrix of 832 x 572 was acquired and reconstructed to 1024 yielding a non-zerofilled voxel size of 0.30 x 0.44 x 1.00 mm(3) (0.13 mm(3)). Two readers were asked to review the images regarding the presence of vascular disease, and to rate, in consensus, the quality of the angiograms on a 5-point scale (5 = excellent through 1 = non-diagnostic). Results were compared with the results in 15 subjects who underwent intracranial TOF MRA at 3.0 T without SENSE (NS-MRA: acquisition time, 7:57 min.; 100 slices). Digital subtraction angiography (DSA) served as standard of reference in the 4/24 patients in whom vascular disease was identified.
RESULTS: S-MRA at 3.0 T was judged to provide image quality that was adequate for diagnosis or better in 24/24. Median score of image quality of S-MRA and NS-MRA were 5 and 5, respectively. In the 4 patients with DSA correlation, a total of 8 pathologic findings (7 steno-occlusive diseases, 1 aneurysm) were correctly identified on S-MRA.
CONCLUSION: The use of SENSE for intracranial TOF MRA at very high imaging matrix is feasible at 3.0 T. Compared to the imaging technique without SENSE, it allows TOF MRA with substantially reduced acquisition time, and with substantially increased anatomic coverage while maintaining image quality of NS-MRA.

Entities:  

Mesh:

Year:  2004        PMID: 14712403     DOI: 10.1055/s-2004-814673

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  12 in total

1.  High-resolution 3D-constructive interference in steady-state MR imaging and 3D time-of-flight MR angiography in neurovascular compression: a comparison between 3T and 1.5T.

Authors:  M Garcia; R Naraghi; T Zumbrunn; J Rösch; P Hastreiter; A Dörfler
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-08       Impact factor: 3.825

2.  Noninvasive evaluation of cerebral arteriovenous malformations by 4D-MRA for preoperative planning and postoperative follow-up in 56 patients: comparison with DSA and intraoperative findings.

Authors:  D R Hadizadeh; G M Kukuk; D T Steck; J Gieseke; H Urbach; H J Tschampa; S Greschus; A Kovàcs; M Möhlenbruch; A Bostroem; H H Schild; W A Willinek
Journal:  AJNR Am J Neuroradiol       Date:  2012-02-02       Impact factor: 3.825

3.  High spatial resolution contrast-enhanced MR angiography of the supraaortic arteries using the quadrature body coil at 3.0T: a feasibility study.

Authors:  Winfried A Willinek; Thomas Bayer; Jürgen Gieseke; Marcus von Falkenhausen; Torsten Sommer; Romhild Hoogeveen; Kai Wilhelm; Horst Urbach; Hans H Schild
Journal:  Eur Radiol       Date:  2006-08-30       Impact factor: 5.315

4.  Advantages and pitfalls in 3T MR brain imaging: a pictorial review.

Authors:  Bernd L Schmitz; Andrik J Aschoff; Martin H K Hoffmann; Georg Grön
Journal:  AJNR Am J Neuroradiol       Date:  2005-10       Impact factor: 3.825

Review 5.  Current diagnostic approaches to subarachnoid haemorrhage.

Authors:  Jean Marie U-King-Im; Brendan Koo; Rikin A Trivedi; Nicholas J Higgins; Keng Y Tay; Justin J Cross; Nagui M Antoun; Jonathan H Gillard
Journal:  Eur Radiol       Date:  2005-02-12       Impact factor: 5.315

Review 6.  MR angiography and imaging for the evaluation of middle cerebral artery atherosclerotic disease.

Authors:  A J Degnan; G Gallagher; Z Teng; J Lu; Q Liu; J H Gillard
Journal:  AJNR Am J Neuroradiol       Date:  2011-09-22       Impact factor: 3.825

Review 7.  Recent advances in parallel imaging for MRI.

Authors:  Jesse Hamilton; Dominique Franson; Nicole Seiberlich
Journal:  Prog Nucl Magn Reson Spectrosc       Date:  2017-05-02       Impact factor: 9.795

8.  Dynamic 3D MR angiography of intra- and extracranial vascular malformations at 3T: a technical note.

Authors:  S Ziyeh; R Strecker; A Berlis; J Weber; J Klisch; I Mader
Journal:  AJNR Am J Neuroradiol       Date:  2005-03       Impact factor: 3.825

9.  Detection of intracranial atherosclerotic steno-occlusive disease with 3D time-of-flight magnetic resonance angiography with sensitivity encoding at 3T.

Authors:  C G Choi; D H Lee; J H Lee; H W Pyun; D W Kang; S U Kwon; J K Kim; S J Kim; D C Suh
Journal:  AJNR Am J Neuroradiol       Date:  2007-03       Impact factor: 3.825

10.  MRI of the pelvis at 3 T: very high spatial resolution with sensitivity encoding and flip-angle sweep technique in clinically acceptable scan time.

Authors:  Nuschin Morakkabati-Spitz; Jürgen Gieseke; Christiane Kuhl; Götz Lutterbey; Marcus von Falkenhausen; Frank Träber; Tjoung-Won Park-Simon; Oliver Zivanovic; Hans H Schild
Journal:  Eur Radiol       Date:  2005-10-14       Impact factor: 5.315