Effects of end-ring/shield configuration on homogeneity and signal-to-noise ratio in a birdcage-type coil loaded with a human head.

Wanzhan Liu1, Christopher M Collins, Pamela J Delp, Michael B Smith.   

Abstract

We modeled four different end-ring/shield configurations of a birdcage coil to examine their effects on field homogeneity and signal-to-noise ratio (SNR) at 64 MHz and 125 MHz. The configurations are defined as: 1) conventional: a conventional cylindrical shield; 2) surrounding shield: a shield with annular extensions to closely shield the end rings; 3) solid connection: a shield with annular extensions connected to the rungs; and 4) thin wire connection: a shield with thin wires connected to the rungs. At both frequencies, the coil with conventional end-ring/shield configuration produces the most homogeneous RF magnetic (B1) field when the coil is empty, but produces the least homogeneous B1 field when the coil is loaded with a human head. The surrounding shield configuration results in the most homogeneous B1 and highest SNR in the coil loaded with the human head at both frequencies, followed closely by the solid connection configuration. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2004        PMID: 14705065     DOI: 10.1002/mrm.10683

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  Comparison of Four Different Shields for Birdcage-Type Coils with Experiments and Numerical Calculations.

Authors:  Wanzhan Liu; Shutong Zhang; Christopher M Collins; Jianli Wang; Michael B Smith
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2006-10-09       Impact factor: 1.176

2.  Assessing the Electromagnetic Fields Generated By a Radiofrequency MRI Body Coil at 64 MHz: Defeaturing Versus Accuracy.

Authors:  Elena Lucano; Micaela Liberti; Gonzalo G Mendoza; Tom Lloyd; Maria Ida Iacono; Francesca Apollonio; Steve Wedan; Wolfgang Kainz; Leonardo M Angelone
Journal:  IEEE Trans Biomed Eng       Date:  2015-12-17       Impact factor: 4.538

3.  Comparison of three commercially available radio frequency coils for human brain imaging at 3 Tesla.

Authors:  Ralf Mekle; Wietske van der Zwaag; Andreas Joosten; Rolf Gruetter
Journal:  MAGMA       Date:  2008-01-10       Impact factor: 2.310

4.  Ultra-high field MRI for primate imaging using the travelling-wave concept.

Authors:  Johannes Mallow; Tim Herrmann; Kyoung-Nam Kim; Joerg Stadler; Judith Mylius; Michael Brosch; Johannes Bernarding
Journal:  MAGMA       Date:  2012-12-12       Impact factor: 2.310

5.  Scan-Rescan Repeatability and Impact of B0 and B1 Field Nonuniformity Corrections in Single-Point Whole-Brain Macromolecular Proton Fraction Mapping.

Authors:  Vasily L Yarnykh; Alena A Kisel; Marina Y Khodanovich
Journal:  J Magn Reson Imaging       Date:  2019-11-18       Impact factor: 4.813

6.  Evaluation of a New 1H/31P Dual-Tuned Birdcage Coil for 31P Spectroscopy.

Authors:  Wm Potter; L Wang; Kk McCully; Q Zhao
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2013-08-01       Impact factor: 1.176

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.