Chronic arterial responses to polymer-controlled paclitaxel-eluting stents: comparison with bare metal stents by serial intravascular ultrasound analyses: data from the randomized TAXUS-II trial.

Kengo Tanabe1, Patrick W Serruys, Muzaffer Degertekin, Giulio Guagliumi, Eberhard Grube, Charles Chan, Thomas Munzel, Jorge Belardi, Witold Ruzyllo, Luc Bilodeau, Henning Kelbaek, John Ormiston, Keith Dawkins, Louis Roy, Bradley H Strauss, Clemens Disco, Jörg Koglin, Mary E Russell, Antonio Colombo.   

Abstract

BACKGROUND: Polymer-controlled paclitaxel-eluting stents have shown a pronounced reduction in neointimal hyperplasia compared with bare metal stents (BMS). The aim of this substudy was to evaluate local arterial responses through the use of serial quantitative intravascular ultrasound (IVUS) analyses in the TAXUS II trial. METHODS AND
RESULTS: TAXUS II was a randomized, double-blind study with 536 patients in 2 consecutive cohorts comparing slow-release (SR; 131 patients) and moderate-release (MR; 135 patients) paclitaxel-eluting stents with BMS (270 patients). This IVUS substudy included patients treated with one study stent who underwent serial IVUS examination after the procedure and at 6-month follow-up (BMS, 152 patients; SR, 81; MR, 81). The analyzed stented segment (15 mm) was divided into 5 subsegments in which mean vessel area (VA), stent area (SA), lumen area (LA), intrastent neointimal hyperplasia area (NIHA), and peristent area (VA-SA) were measured. NIHA was significantly reduced in SR (0.7+/-0.9 mm2, P<0.001) and MR (0.6+/-0.8 mm2, P<0.001) compared with BMS (1.9+/-1.5 mm2), with no differences between the two paclitaxel-eluting release formulations. Longitudinal distribution of neointimal hyperplasia throughout the paclitaxel-eluting stent was uniform. Neointimal growth was independent of peristent area at postprocedure examination in all groups. There were progressive increases in peristent area from BMS to SR to MR (0.5+/-1.7, 1.0+/-1.8, and 1.4+/-2.0 mm2, respectively; P<0.001). The increase in peristent area was directly correlated with increases in VA.
CONCLUSIONS: Both SR and MR paclitaxel-eluting stents prevent neointimal formation to the same degree compared with BMS. However, the difference in peristent remodeling suggests a release-dependent effect between SR and MR.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14691036     DOI: 10.1161/01.CIR.0000109137.51122.49

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  7 in total

1.  Comparison of intravascular ultrasonic imaging with versus without incomplete stent apposition at follow-up after drug-eluting stent implantation.

Authors:  Juying Qian; Feng Zhang; Hongyi Wu; Bing Fan; Lei Ge; Junbo Ge
Journal:  Int J Cardiovasc Imaging       Date:  2007-08-17       Impact factor: 2.357

2.  Atherosclerotic plaque behind the stent changes after bare-metal and drug-eluting stent implantation in humans: Implications for late stent failure?

Authors:  Ioannis Andreou; Saeko Takahashi; Masaya Tsuda; Koki Shishido; Antonios P Antoniadis; Michail I Papafaklis; Shingo Mizuno; Ahmet U Coskun; Shigeru Saito; Charles L Feldman; Elazer R Edelman; Peter H Stone
Journal:  Atherosclerosis       Date:  2016-07-22       Impact factor: 5.162

Review 3.  Efficacy of drug eluting stents in patients with and without diabetes mellitus: indirect comparison of controlled trials.

Authors:  C Stettler; S Allemann; M Egger; S Windecker; B Meier; P Diem
Journal:  Heart       Date:  2005-10-26       Impact factor: 5.994

4.  [New developments in drug-eluting stents].

Authors:  M Kollum; C Bode
Journal:  Herz       Date:  2011-05       Impact factor: 1.443

5.  Diffusion-limited binding explains binary dose response for local arterial and tumour drug delivery.

Authors:  A R Tzafriri; A D Levin; E R Edelman
Journal:  Cell Prolif       Date:  2009-03-31       Impact factor: 6.831

6.  Quantitative multi-modality imaging analysis of a fully bioresorbable stent: a head-to-head comparison between QCA, IVUS and OCT.

Authors:  Juan Luis Gutiérrez-Chico; Patrick W Serruys; Chrysafios Girasis; Scot Garg; Yoshinobu Onuma; Salvatore Brugaletta; Héctor García-García; Gerrit-Anne van Es; Evelyn Regar
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-26       Impact factor: 2.357

7.  Luminal flow amplifies stent-based drug deposition in arterial bifurcations.

Authors:  Vijaya B Kolachalama; Evan G Levine; Elazer R Edelman
Journal:  PLoS One       Date:  2009-12-02       Impact factor: 3.240